DBA Data[Home] [Help]

APPS.OKL_EC_EVALUATE_PVT dependencies on FND_NUMBER

Line 503: l_numval1 := fnd_number.canonical_to_number(p_value1);

499: okl_debug_pub.log_debug(fnd_log.level_procedure
500: ,l_module
501: ,'begin debug OKLRECUB.pls.pls call validate_trade_in_value');
502: END IF;
503: l_numval1 := fnd_number.canonical_to_number(p_value1);
504: l_numval2 := fnd_number.canonical_to_number(p_value2);
505:
506: IF (p_trade_in_value >= l_numval1 AND p_trade_in_value <= l_numval2) THEN
507: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN

Line 504: l_numval2 := fnd_number.canonical_to_number(p_value2);

500: ,l_module
501: ,'begin debug OKLRECUB.pls.pls call validate_trade_in_value');
502: END IF;
503: l_numval1 := fnd_number.canonical_to_number(p_value1);
504: l_numval2 := fnd_number.canonical_to_number(p_value2);
505:
506: IF (p_trade_in_value >= l_numval1 AND p_trade_in_value <= l_numval2) THEN
507: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN
508: okl_debug_pub.log_debug(fnd_log.level_procedure

Line 906: l_numval1 := fnd_number.canonical_to_number(p_value1);

902: okl_debug_pub.log_debug(fnd_log.level_procedure
903: ,l_module
904: ,'begin debug OKLRECUB.pls.pls call validate_deal_size');
905: END IF;
906: l_numval1 := fnd_number.canonical_to_number(p_value1);
907: l_numval2 := fnd_number.canonical_to_number(p_value2);
908:
909: IF (p_deal_size >= l_numval1 AND p_deal_size <= l_numval2) THEN
910: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN

Line 907: l_numval2 := fnd_number.canonical_to_number(p_value2);

903: ,l_module
904: ,'begin debug OKLRECUB.pls.pls call validate_deal_size');
905: END IF;
906: l_numval1 := fnd_number.canonical_to_number(p_value1);
907: l_numval2 := fnd_number.canonical_to_number(p_value2);
908:
909: IF (p_deal_size >= l_numval1 AND p_deal_size <= l_numval2) THEN
910: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN
911: okl_debug_pub.log_debug(fnd_log.level_procedure

Line 1110: l_numval1 := fnd_number.canonical_to_number(p_value1);

1106: -- check for logging on STATEMENT level
1107:
1108: is_debug_statement_on := okl_debug_pub.check_log_on(l_module
1109: ,fnd_log.level_statement);
1110: l_numval1 := fnd_number.canonical_to_number(p_value1);
1111: l_numval2 := fnd_number.canonical_to_number(p_value2);
1112:
1113: IF (p_deal_size >= l_numval1 AND p_deal_size <= l_numval2) THEN
1114: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN

Line 1111: l_numval2 := fnd_number.canonical_to_number(p_value2);

1107:
1108: is_debug_statement_on := okl_debug_pub.check_log_on(l_module
1109: ,fnd_log.level_statement);
1110: l_numval1 := fnd_number.canonical_to_number(p_value1);
1111: l_numval2 := fnd_number.canonical_to_number(p_value2);
1112:
1113: IF (p_deal_size >= l_numval1 AND p_deal_size <= l_numval2) THEN
1114: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN
1115: okl_debug_pub.log_debug(fnd_log.level_procedure

Line 1320: l_formatted_amt := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)

1316: END IF;
1317: IF p_okl_ec_rec.validation_mode = 'QA' THEN
1318: l_index := p_okl_ec_rec.qa_result_tbl.COUNT + 1;
1319: IF fun_ret = 0 THEN
1320: l_formatted_amt := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)
1321: ,p_okl_ec_rec.currency_code);
1322: p_okl_ec_rec.qa_result_tbl(l_index).message := get_msg_single(ec_tbl(i).ec_name
1323: ,l_operator_code
1324: ,l_formatted_amt

Line 1452: l_formatted_amt1 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)

1448: END IF;
1449: IF p_okl_ec_rec.validation_mode = 'QA' THEN
1450: l_index := p_okl_ec_rec.qa_result_tbl.COUNT + 1;
1451: IF fun_ret = 0 THEN
1452: l_formatted_amt1 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)
1453: ,p_okl_ec_rec.currency_code);
1454: l_formatted_amt2 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value2)
1455: ,p_okl_ec_rec.currency_code);
1456: p_okl_ec_rec.qa_result_tbl(l_index).message := get_msg_range(ec_tbl(i).ec_name

Line 1454: l_formatted_amt2 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value2)

1450: l_index := p_okl_ec_rec.qa_result_tbl.COUNT + 1;
1451: IF fun_ret = 0 THEN
1452: l_formatted_amt1 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)
1453: ,p_okl_ec_rec.currency_code);
1454: l_formatted_amt2 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value2)
1455: ,p_okl_ec_rec.currency_code);
1456: p_okl_ec_rec.qa_result_tbl(l_index).message := get_msg_range(ec_tbl(i).ec_name
1457: ,l_formatted_amt1
1458: ,l_formatted_amt2

Line 1526: l_formatted_amt := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)

1522: END IF;
1523: IF p_okl_ec_rec.validation_mode = 'QA' THEN
1524: l_index := p_okl_ec_rec.qa_result_tbl.COUNT + 1;
1525: IF fun_ret = 0 THEN
1526: l_formatted_amt := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)
1527: ,p_okl_ec_rec.currency_code);
1528: p_okl_ec_rec.qa_result_tbl(l_index).message := get_msg_single(ec_tbl(i).ec_name
1529: ,l_operator_code
1530: ,l_formatted_amt

Line 1560: l_num_value_tbl(k) := fnd_number.canonical_to_number(ec_val_rec.crit_cat_value2);

1556: ,'dd-mm-yyyy')))
1557: AND (p_okl_ec_rec.item_table.COUNT > 0)) THEN
1558: k := 1;
1559: FOR ec_val_rec IN get_ec_values(ec_tbl(i).criteria_id) LOOP
1560: l_num_value_tbl(k) := fnd_number.canonical_to_number(ec_val_rec.crit_cat_value2);
1561: k := k + 1;
1562: END LOOP;
1563:
1564: --this validate function will return either 1 or 0 only

Line 1624: l_num_value_tbl(k) := fnd_number.canonical_to_number(ec_val_rec.crit_cat_value2);

1620: ,'dd-mm-yyyy')))
1621: AND (p_okl_ec_rec.item_categories_table.COUNT > 0)) THEN
1622: k := 1;
1623: FOR ec_val_rec IN get_ec_values(ec_tbl(i).criteria_id) LOOP
1624: l_num_value_tbl(k) := fnd_number.canonical_to_number(ec_val_rec.crit_cat_value2);
1625: k := k + 1;
1626: END LOOP;
1627:
1628: --this validate function will return either 1 or 0 only

Line 1688: l_num_value_tbl(k) := fnd_number.canonical_to_number(ec_val_rec.crit_cat_value2);

1684: ,'dd-mm-yyyy')))
1685: AND (p_okl_ec_rec.term IS NOT NULL)) THEN
1686: k := 1;
1687: FOR ec_val_rec IN get_ec_values(ec_tbl(i).criteria_id) LOOP
1688: l_num_value_tbl(k) := fnd_number.canonical_to_number(ec_val_rec.crit_cat_value2);
1689:
1690: --dbms_output.put_line('l_num_value_tbl(k) = '||l_num_value_tbl(k));
1691:
1692: k := k + 1;

Line 1858: l_formatted_amt1 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)

1854: END IF;
1855: IF p_okl_ec_rec.validation_mode = 'QA' THEN
1856: l_index := p_okl_ec_rec.qa_result_tbl.COUNT + 1;
1857: IF fun_ret = 0 THEN
1858: l_formatted_amt1 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)
1859: ,p_okl_ec_rec.currency_code);
1860: l_formatted_amt2 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value2)
1861: ,p_okl_ec_rec.currency_code);
1862: p_okl_ec_rec.qa_result_tbl(l_index).message := get_msg_range(ec_tbl(i).ec_name

Line 1860: l_formatted_amt2 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value2)

1856: l_index := p_okl_ec_rec.qa_result_tbl.COUNT + 1;
1857: IF fun_ret = 0 THEN
1858: l_formatted_amt1 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value1)
1859: ,p_okl_ec_rec.currency_code);
1860: l_formatted_amt2 := okl_accounting_util.format_amount(fnd_number.canonical_to_number(l_value2)
1861: ,p_okl_ec_rec.currency_code);
1862: p_okl_ec_rec.qa_result_tbl(l_index).message := get_msg_range(ec_tbl(i).ec_name
1863: ,l_formatted_amt1
1864: ,l_formatted_amt2

Line 2230: l_num_value_tbl(k) := fnd_number.canonical_to_number(ac_val_rec.crit_cat_value1);

2226: ,'dd-mm-yyyy')))
2227: AND (p_okl_ac_rec.term IS NOT NULL)) THEN
2228: k := 1;
2229: FOR ac_val_rec IN get_ac_values(ac_tbl(i).criteria_id) LOOP
2230: l_num_value_tbl(k) := fnd_number.canonical_to_number(ac_val_rec.crit_cat_value1);
2231: l_adjustment_factors_tbl(k) := ac_val_rec.adjustment_factor;
2232:
2233: --dbms_output.put_line('l_num_value_tbl(k) = '||l_num_value_tbl(k));
2234:

Line 2528: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);

2524: IF ec1_tbl(i).data_type_code = 'NUMBER' THEN
2525:
2526: --dbms_output.put_line('datatype = number ');
2527:
2528: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);
2529: l_ec1_numval2 := fnd_number.canonical_to_number(l_ec1_value2);
2530: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);
2531: l_ec2_numval2 := fnd_number.canonical_to_number(l_ec2_value2);
2532:

Line 2529: l_ec1_numval2 := fnd_number.canonical_to_number(l_ec1_value2);

2525:
2526: --dbms_output.put_line('datatype = number ');
2527:
2528: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);
2529: l_ec1_numval2 := fnd_number.canonical_to_number(l_ec1_value2);
2530: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);
2531: l_ec2_numval2 := fnd_number.canonical_to_number(l_ec2_value2);
2532:
2533: --dbms_output.put_line(' l_ec1_numval1= '||l_ec1_numval1);

Line 2530: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);

2526: --dbms_output.put_line('datatype = number ');
2527:
2528: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);
2529: l_ec1_numval2 := fnd_number.canonical_to_number(l_ec1_value2);
2530: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);
2531: l_ec2_numval2 := fnd_number.canonical_to_number(l_ec2_value2);
2532:
2533: --dbms_output.put_line(' l_ec1_numval1= '||l_ec1_numval1);
2534: --dbms_output.put_line(' l_ec1_numval2= '||l_ec1_numval2);

Line 2531: l_ec2_numval2 := fnd_number.canonical_to_number(l_ec2_value2);

2527:
2528: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);
2529: l_ec1_numval2 := fnd_number.canonical_to_number(l_ec1_value2);
2530: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);
2531: l_ec2_numval2 := fnd_number.canonical_to_number(l_ec2_value2);
2532:
2533: --dbms_output.put_line(' l_ec1_numval1= '||l_ec1_numval1);
2534: --dbms_output.put_line(' l_ec1_numval2= '||l_ec1_numval2);
2535: --dbms_output.put_line(' l_ec2_numval1= '||l_ec2_numval1);

Line 2652: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);

2648: ,l_ec2_value1
2649: ,l_ec2_value2 ;
2650: CLOSE get_ec_values;
2651: IF ec1_tbl(i).data_type_code = 'NUMBER' THEN
2652: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);
2653: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);
2654: IF l_ec1_operator_code = 'EQ' AND l_ec2_operator_code = 'EQ' THEN
2655: IF l_ec1_numval1 <> l_ec2_numval1 THEN
2656: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN

Line 2653: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);

2649: ,l_ec2_value2 ;
2650: CLOSE get_ec_values;
2651: IF ec1_tbl(i).data_type_code = 'NUMBER' THEN
2652: l_ec1_numval1 := fnd_number.canonical_to_number(l_ec1_value1);
2653: l_ec2_numval1 := fnd_number.canonical_to_number(l_ec2_value1);
2654: IF l_ec1_operator_code = 'EQ' AND l_ec2_operator_code = 'EQ' THEN
2655: IF l_ec1_numval1 <> l_ec2_numval1 THEN
2656: IF (l_debug_enabled = 'Y' AND is_debug_procedure_on) THEN
2657: okl_debug_pub.log_debug(fnd_log.level_procedure