DBA Data[Home] [Help]

APPS.PA_STATUS_PUB dependencies on PA_UTILS

Line 303: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'

299: CLOSE c_get_structure_information;
300:
301: /*IF PA_PROGRESS_UTILS.CHECK_VALID_AS_OF_DATE(TRUNC(p_as_of_date), l_project_id_out, l_str_id, 'PA_STRUCTURES', l_str_id ) = 'N'
302: THEN
303: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'
304: ,p_msg_name => 'PA_TP_INV_AOD2');
305: p_return_status := FND_API.G_RET_STS_ERROR;
306: RAISE FND_API.G_EXC_ERROR;
307: END IF;*/

Line 496: PA_UTILS.ADD_MESSAGE(p_app_short_name => 'PA',

492: FETCH c_verify_rlm_id INTO l_valid_rlm_id, l_ta_display_flag;
493: CLOSE c_verify_rlm_id;
494:
495: IF l_valid_rlm_id = 'N' THEN
496: PA_UTILS.ADD_MESSAGE(p_app_short_name => 'PA',
497: p_msg_name => 'PA_TP_INV_ASSGN_AMG',
498: P_TOKEN1 => 'OBJECT_ID',
499: P_VALUE1 => p_object_id);
500: p_return_status := FND_API.G_RET_STS_ERROR;

Line 729: PA_UTILS.ADD_MESSAGE('PA', 'PA_PROG_BACKDATE_NOT_ALLOW',

725: l_progress_mode := 'FUTURE';
726: ELSE
727: IF (l_object_type = 'PA_ASSIGNMENTS' OR l_object_type = 'PA_DELIVERABLES')
728: THEN
729: PA_UTILS.ADD_MESSAGE('PA', 'PA_PROG_BACKDATE_NOT_ALLOW',
730: 'OBJECT_ID', l_object_id);
731: p_return_status := FND_API.G_RET_STS_ERROR;
732: RAISE FND_API.G_EXC_ERROR;
733: END IF;

Line 756: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'

752: if (l_object_type = 'PA_DELIVERABLES' OR l_object_type = 'PA_TASKS' OR l_object_type = 'PA_STRUCTURES')then
753: IF PA_PROGRESS_UTILS.CHECK_VALID_AS_OF_DATE(TRUNC(l_as_of_date), l_project_id_out, l_object_id, l_object_type ) = 'N'
754: AND trunc(nvl(l_latest_as_of_date,l_as_of_date + 1 )) <> TRUNC(l_as_of_date)
755: THEN
756: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'
757: ,p_msg_name => 'PA_TP_INV_AOD2');
758: p_return_status := FND_API.G_RET_STS_ERROR;
759: RAISE FND_API.G_EXC_ERROR;
760: END IF;

Line 766: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'

762: if (l_object_type = 'PA_ASSIGNMENTS')then
763: IF PA_PROGRESS_UTILS.CHECK_VALID_AS_OF_DATE(TRUNC(l_as_of_date), l_project_id_out, l_object_id, l_object_type, l_task_id ) = 'N'
764: AND trunc(nvl(l_latest_as_of_date,l_as_of_date + 1 )) <> TRUNC(l_as_of_date)
765: THEN
766: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'
767: ,p_msg_name => 'PA_TP_INV_AOD2');
768: p_return_status := FND_API.G_RET_STS_ERROR;
769: RAISE FND_API.G_EXC_ERROR;
770: END IF;

Line 1965: -- PA_UTILS.ADD_MESSAGE('PA', 'PA_PROG_WRONG_OBJ_TYPE',

1961: ELSE
1962: -- IF (G_TASK_PROGRESS_in_tbl(G_TASK_PROGRESS_tbl_count).OBJECT_TYPE = 'PA_ASSIGNMENTS' OR
1963: -- G_TASK_PROGRESS_in_tbl(G_TASK_PROGRESS_tbl_count).OBJECT_TYPE = 'PA_DELIVERABLES')
1964: -- THEN
1965: -- PA_UTILS.ADD_MESSAGE('PA', 'PA_PROG_WRONG_OBJ_TYPE',
1966: -- 'OBJECT_ID', G_TASK_PROGRESS_in_tbl(i).OBJECT_ID);
1967: --
1968: -- END IF;
1969: l_progress_mode := 'BACKDATED';

Line 2169: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'

2165:
2166: -- it has to be validated for each task for backdate and correct progress flows
2167: /* IF PA_PROGRESS_UTILS.CHECK_VALID_AS_OF_DATE( TRUNC(g_as_of_date), l_project_id_out, l_structure_id, 'PA_STRUCTURES', l_structure_id --Bug 3764224 ) = 'N'
2168: THEN
2169: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'
2170: ,p_msg_name => 'PA_TP_INV_AOD2');
2171: p_return_status := FND_API.G_RET_STS_ERROR;
2172: RAISE FND_API.G_EXC_ERROR;
2173: END IF; */

Line 2340: PA_UTILS.ADD_MESSAGE('PA', 'PA_PS_TASK_NAME_NUM_ERR',

2336:
2337: IF l_data IS NOT NULL THEN
2338: FND_MSG_PUB.DELETE_MSG(p_msg_index => l_msg_count);
2339:
2340: PA_UTILS.ADD_MESSAGE('PA', 'PA_PS_TASK_NAME_NUM_ERR',
2341: 'ROWNUM', 'ROW# '||i,--Added by rtarway for bug 4293075
2342: 'TASK_NAME', G_TASK_PROGRESS_in_tbl(i).TASK_NAME,
2343: 'TASK_NUMBER', G_TASK_PROGRESS_in_tbl(i).TASK_NUMBER,
2344: 'MESSAGE', l_data);

Line 2356: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'

2352:
2353: -- rtarway, BUG 3964278
2354: IF G_STRUCTURE_TYPE = 'WORKPLAN' and l_is_progress_status_null = 'Y'
2355: THEN
2356: PA_UTILS.ADD_MESSAGE( p_app_short_name => 'PA'
2357: ,p_msg_name => 'PA_TP_STATUS_NOT_DEFINED');
2358: p_return_status := FND_API.G_RET_STS_ERROR;
2359: RAISE FND_API.G_EXC_ERROR;
2360: END IF;

Line 2434: PA_UTILS.ADD_MESSAGE(p_app_short_name => 'PA',

2430: p_error_text => SUBSTRB('PA_FP_MAINTAIN_ACTUAL_PUB.MAINTAIN_ACTUAL_AMT_WRP:'||SQLERRM,1,120));
2431: RAISE FND_API.G_EXC_ERROR;
2432: END;
2433: IF l_return_status <> FND_API.G_RET_STS_SUCCESS THEN
2434: PA_UTILS.ADD_MESSAGE(p_app_short_name => 'PA',
2435: p_msg_name => l_msg_data);
2436: p_return_status := 'E';
2437: RAISE FND_API.G_EXC_ERROR;
2438: END IF;

Line 2764: PA_UTILS.ADD_MESSAGE(p_app_short_name => 'PA',

2760: ,x_msg_count => l_msg_count
2761: ,x_msg_data => l_msg_data );
2762: IF l_return_status <> FND_API.G_RET_STS_SUCCESS
2763: THEN
2764: PA_UTILS.ADD_MESSAGE(p_app_short_name => 'PA',
2765: p_msg_name => l_msg_data
2766: );
2767: p_msg_data := l_msg_data;
2768: p_return_status := 'E';