DBA Data[Home] [Help]

APPS.ENG_CHANGE_LIFECYCLE_UTIL dependencies on ENG_CHANGE_ORDER_TYPES

Line 312: ENG_CHANGE_ORDER_TYPES ChangeCategory,

308: eec.change_mgmt_type_code ,
309: changecategory.base_change_mgmt_type_code,
310: type_appl.application_id
311: FROM ENG_ENGINEERING_CHANGES eec,
312: ENG_CHANGE_ORDER_TYPES ChangeCategory,
313: ENG_CHANGE_TYPE_APPLICATIONS type_appl
314: WHERE type_appl.change_type_id = ChangeCategory.change_order_type_id
315: and type_appl.application_id = p_appl_id
316: AND ChangeCategory.type_classification = 'CATEGORY'

Line 351: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

347: l_fnd_user_id NUMBER := TO_NUMBER(FND_PROFILE.VALUE('USER_ID'));
348: l_fnd_login_id NUMBER := TO_NUMBER(FND_PROFILE.VALUE('LOGIN_ID'));
349:
350: l_cm_type_code eng_engineering_changes.CHANGE_MGMT_TYPE_CODE%TYPE;
351: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
352:
353: l_next_status_code NUMBER;
354:
355: --l_curr_status_code NUMBER;

Line 399: eng_change_order_types ecot

395: ecot.base_change_mgmt_type_code
396: INTO l_cm_type_code, l_next_status_code, --l_curr_status_code
397: l_base_cm_type_code
398: FROM eng_engineering_changes eec,
399: eng_change_order_types ecot
400: WHERE eec.change_id = p_change_id
401: AND ecot.change_order_type_id = eec.change_order_type_id;
402:
403: --x_curr_status_code := l_curr_status_code;

Line 464: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

460: ,x_last_status_code OUT NOCOPY NUMBER
461: )
462: IS
463: l_cm_type_code eng_engineering_changes.CHANGE_MGMT_TYPE_CODE%TYPE;
464: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
465: l_max_phase_sn eng_lifecycle_statuses.sequence_number%TYPE;
466: l_start_date eng_lifecycle_statuses.start_date%TYPE;
467: BEGIN
468: -- Standard Start of API savepoint

Line 491: eng_change_order_types ecot

487: -- Get the change header's cm type, and promote_status_code
488: SELECT eec.change_mgmt_type_code, ecot.base_change_mgmt_type_code
489: INTO l_cm_type_code, l_base_cm_type_code
490: FROM eng_engineering_changes eec,
491: eng_change_order_types ecot
492: WHERE eec.change_id = p_change_id
493: AND ecot.change_order_type_id = eec.change_order_type_id;
494:
495: IF (l_base_cm_type_code = G_ENG_ECO) THEN

Line 615: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

611:
612: l_wf_item_key wf_item_activity_statuses.item_key%TYPE := NULL;
613:
614: l_cm_type_code eng_engineering_changes.change_mgmt_type_code%TYPE;
615: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
616:
617: l_param_list WF_PARAMETER_LIST_T := WF_PARAMETER_LIST_T();
618:
619: l_appl_id NUMBER ;

Line 686: eng_change_order_types ecot

682: -- Select cm type and base type code for upcoming API calls
683: SELECT eec.change_mgmt_type_code, ecot.base_change_mgmt_type_code
684: INTO l_cm_type_code, l_base_cm_type_code
685: FROM eng_engineering_changes eec,
686: eng_change_order_types ecot
687: WHERE eec.change_id = p_change_id
688: AND ecot.change_order_type_id = eec.change_order_type_id;
689:
690: l_doc_lc_object_flag := ENG_DOCUMENT_UTIL.Is_Dom_Document_Lifecycle

Line 820: eng_change_order_types ecot

816: -- Select cm type and base type code for upcoming API calls
817: /*SELECT eec.change_mgmt_type_code, ecot.base_change_mgmt_type_code
818: INTO l_cm_type_code, l_base_cm_type_code
819: FROM eng_engineering_changes eec,
820: eng_change_order_types ecot
821: WHERE eec.change_id = p_change_id
822: AND ecot.change_order_type_id = eec.change_order_type_id;*/
823:
824:

Line 2007: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

2003: l_ri_phase_sn eng_lifecycle_statuses.sequence_number%TYPE;
2004:
2005: l_last_imp_flag VARCHAR2(1) := 'N';
2006: l_cm_type_code eng_engineering_changes.CHANGE_MGMT_TYPE_CODE%TYPE;
2007: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
2008: l_imp_eco_flag VARCHAR2(1) := 'N';
2009:
2010: --l_co_type_id eng_engineering_changes.CHANGE_ORDER_TYPE_ID%TYPE;
2011: l_auto_prop_flag eng_type_org_properties.AUTO_PROPAGATE_FLAG%TYPE;

Line 2331: eng_change_order_types ecot

2327: -- Get the change header's cm type and base cm type
2328: SELECT eec.change_mgmt_type_code, ecot.base_change_mgmt_type_code, eec.approval_status_type
2329: INTO l_cm_type_code, l_base_cm_type_code, l_eco_approval_status
2330: FROM eng_engineering_changes eec,
2331: eng_change_order_types ecot
2332: WHERE eec.change_id = p_change_id
2333: AND ecot.change_order_type_id = eec.change_order_type_id;
2334:
2335: -- If there are still open lines or mandatory tasks, raise error message

Line 4855: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

4851: l_chg_appr_status eng_engineering_changes.approval_status_type%TYPE;
4852: l_curr_appr_status eng_engineering_changes.approval_status_type%TYPE;
4853:
4854: l_cm_type_code eng_engineering_changes.change_mgmt_type_code%TYPE;
4855: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
4856:
4857: l_curr_status_code NUMBER;
4858: l_curr_status_type NUMBER;
4859: l_next_status_code NUMBER;

Line 4978: eng_change_order_types ecot

4974: ecot.base_change_mgmt_type_code
4975: INTO l_curr_status_code, l_next_status_code, l_cm_type_code,
4976: l_base_cm_type_code
4977: FROM eng_engineering_changes eec,
4978: eng_change_order_types ecot
4979: WHERE eec.change_id = p_change_id
4980: AND ecot.change_order_type_id = eec.change_order_type_id;
4981:
4982: -- Get the current phase status_type

Line 5481: eng_change_order_types ecot

5477: ecot.base_change_mgmt_type_code
5478: INTO l_cm_type_code, l_chg_notice, l_org_id,
5479: l_base_cm_type_code
5480: FROM eng_engineering_changes eec,
5481: eng_change_order_types ecot
5482: WHERE eec.change_id = p_change_id
5483: AND ecot.change_order_type_id = eec.change_order_type_id;
5484:
5485: -- Complete attachment approval if needed

Line 6520: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

6516: l_fnd_user_id NUMBER := TO_NUMBER(FND_PROFILE.VALUE('USER_ID'));
6517: l_fnd_login_id NUMBER := TO_NUMBER(FND_PROFILE.VALUE('LOGIN_ID'));
6518:
6519: l_cm_type_code eng_engineering_changes.change_mgmt_type_code%TYPE;
6520: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
6521: l_bug_number NUMBER := 0;
6522:
6523: l_initial_phase_sn eng_lifecycle_statuses.sequence_number%TYPE;
6524:

Line 6806: eng_change_order_types ecot

6802: -- Select cm type and base type code for upcoming API calls
6803: SELECT eec.change_mgmt_type_code, ecot.base_change_mgmt_type_code
6804: INTO l_cm_type_code, l_base_cm_type_code
6805: FROM eng_engineering_changes eec,
6806: eng_change_order_types ecot
6807: WHERE eec.change_id = p_change_id
6808: AND ecot.change_order_type_id = eec.change_order_type_id;
6809:
6810: -- for nir set all included item approval status to submitted for approval

Line 7264: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;

7260:
7261: l_doc_lc_object_flag BOOLEAN := FALSE ;
7262:
7263: l_cm_type_code eng_engineering_changes.CHANGE_MGMT_TYPE_CODE%TYPE;
7264: l_base_cm_type_code eng_change_order_types.BASE_CHANGE_MGMT_TYPE_CODE%TYPE;
7265:
7266: l_next_status_code NUMBER;
7267: l_reset_status_code NUMBER;
7268: l_last_status_code NUMBER;

Line 7284: eng_change_order_types ecot

7280: , eec.promote_status_code
7281: , eec.change_mgmt_type_code
7282: , ecot.base_change_mgmt_type_code
7283: FROM eng_engineering_changes eec,
7284: eng_change_order_types ecot
7285: WHERE eec.change_id = c_change_id
7286: AND ecot.change_order_type_id = eec.change_order_type_id ;
7287:
7288: