DBA Data[Home] [Help]

APPS.OTA_FTU_SHD dependencies on FND_MESSAGE

Line 22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');

18: --
19: Begin
20: --
21: If (p_constraint_name = 'OTA_PVT_FRM_THREAD_USERS_PK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else

Line 23: fnd_message.set_token('PROCEDURE', l_proc);

19: Begin
20: --
21: If (p_constraint_name = 'OTA_PVT_FRM_THREAD_USERS_PK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');

Line 24: fnd_message.set_token('STEP','5');

20: --
21: If (p_constraint_name = 'OTA_PVT_FRM_THREAD_USERS_PK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);

Line 25: fnd_message.raise_error;

21: If (p_constraint_name = 'OTA_PVT_FRM_THREAD_USERS_PK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);

Line 27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');

23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;

Line 28: fnd_message.set_token('PROCEDURE', l_proc);

24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;
32: --

Line 29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);

25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;
32: --
33: End constraint_error;

Line 30: fnd_message.raise_error;

26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;
32: --
33: End constraint_error;
34: --

Line 109: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');

105: Close C_Sel1;
106: --
107: -- The primary key is invalid therefore we must error
108: --
109: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
110: fnd_message.raise_error;
111: End If;
112: Close C_Sel1;
113: If (p_object_version_number

Line 110: fnd_message.raise_error;

106: --
107: -- The primary key is invalid therefore we must error
108: --
109: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
110: fnd_message.raise_error;
111: End If;
112: Close C_Sel1;
113: If (p_object_version_number
114: <> ota_ftu_shd.g_old_rec.object_version_number) Then

Line 115: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');

111: End If;
112: Close C_Sel1;
113: If (p_object_version_number
114: <> ota_ftu_shd.g_old_rec.object_version_number) Then
115: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
116: fnd_message.raise_error;
117: End If;
118: l_fct_ret := true;
119: End If;

Line 116: fnd_message.raise_error;

112: Close C_Sel1;
113: If (p_object_version_number
114: <> ota_ftu_shd.g_old_rec.object_version_number) Then
115: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
116: fnd_message.raise_error;
117: End If;
118: l_fct_ret := true;
119: End If;
120: End If;

Line 197: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');

193: Close C_Sel1;
194: --
195: -- The primary key is invalid therefore we must error
196: --
197: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
198: fnd_message.raise_error;
199: End If;
200: Close C_Sel1;
201: If (p_object_version_number

Line 198: fnd_message.raise_error;

194: --
195: -- The primary key is invalid therefore we must error
196: --
197: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
198: fnd_message.raise_error;
199: End If;
200: Close C_Sel1;
201: If (p_object_version_number
202: <> ota_ftu_shd.g_old_rec.object_version_number) Then

Line 203: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');

199: End If;
200: Close C_Sel1;
201: If (p_object_version_number
202: <> ota_ftu_shd.g_old_rec.object_version_number) Then
203: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
204: fnd_message.raise_error;
205: End If;
206: --
207: hr_utility.set_location(' Leaving:'||l_proc, 10);

Line 204: fnd_message.raise_error;

200: Close C_Sel1;
201: If (p_object_version_number
202: <> ota_ftu_shd.g_old_rec.object_version_number) Then
203: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
204: fnd_message.raise_error;
205: End If;
206: --
207: hr_utility.set_location(' Leaving:'||l_proc, 10);
208: --

Line 217: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');

213: --
214: -- The object is locked therefore we need to supply a meaningful
215: -- error message.
216: --
217: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');
218: fnd_message.set_token('TABLE_NAME', 'ota_pvt_frm_thread_users');
219: fnd_message.raise_error;
220: End lck;
221: --

Line 218: fnd_message.set_token('TABLE_NAME', 'ota_pvt_frm_thread_users');

214: -- The object is locked therefore we need to supply a meaningful
215: -- error message.
216: --
217: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');
218: fnd_message.set_token('TABLE_NAME', 'ota_pvt_frm_thread_users');
219: fnd_message.raise_error;
220: End lck;
221: --
222: -- ----------------------------------------------------------------------------

Line 219: fnd_message.raise_error;

215: -- error message.
216: --
217: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');
218: fnd_message.set_token('TABLE_NAME', 'ota_pvt_frm_thread_users');
219: fnd_message.raise_error;
220: End lck;
221: --
222: -- ----------------------------------------------------------------------------
223: -- |-----------------------------< convert_args >-----------------------------|