DBA Data[Home] [Help]

APPS.ISC_DBI_BOOK_SUM2_REF_PKG dependencies on FII_UTIL

Line 24: FII_UTIL.Start_Timer;

20:
21: BIS_COLLECTION_UTILITIES.put_line(' ');
22: BIS_COLLECTION_UTILITIES.put_line('Start to Refresh '|| p_mview_name);
23:
24: FII_UTIL.Start_Timer;
25:
26: DBMS_MVIEW.REFRESH(
27: list => p_mview_name,
28: method => '?',

Line 32: FII_UTIL.Stop_Timer;

28: method => '?',
29: parallelism => l_degree
30: );
31:
32: FII_UTIL.Stop_Timer;
33: FII_UTIL.Print_Timer(p_mview_name || ' has been refreshed in ');
34:
35: l_sql_stmt := 'SELECT count(*) FROM ' || p_mview_name ;
36: EXECUTE IMMEDIATE l_sql_stmt INTO l_row_count;

Line 33: FII_UTIL.Print_Timer(p_mview_name || ' has been refreshed in ');

29: parallelism => l_degree
30: );
31:
32: FII_UTIL.Stop_Timer;
33: FII_UTIL.Print_Timer(p_mview_name || ' has been refreshed in ');
34:
35: l_sql_stmt := 'SELECT count(*) FROM ' || p_mview_name ;
36: EXECUTE IMMEDIATE l_sql_stmt INTO l_row_count;
37:

Line 76: FII_UTIL.Start_Timer;

72: l_to_date := sysdate;
73:
74: BIS_COLLECTION_UTILITIES.put_line('Updating ISC_BOOK_SUM2_PDUE_F');
75:
76: FII_UTIL.Start_Timer;
77:
78: UPDATE isc_book_sum2_pdue_f
79: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
80: WHERE time_snapshot_date_id = trunc(sysdate);

Line 82: FII_UTIL.Stop_Timer;

78: UPDATE isc_book_sum2_pdue_f
79: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
80: WHERE time_snapshot_date_id = trunc(sysdate);
81:
82: FII_UTIL.Stop_Timer;
83: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_PDUE_F in');
84:
85: BIS_COLLECTION_UTILITIES.put_line(' ');
86: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_PDUE_F');

Line 83: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_PDUE_F in');

79: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
80: WHERE time_snapshot_date_id = trunc(sysdate);
81:
82: FII_UTIL.Stop_Timer;
83: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_PDUE_F in');
84:
85: BIS_COLLECTION_UTILITIES.put_line(' ');
86: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_PDUE_F');
87:

Line 88: FII_UTIL.Start_Timer;

84:
85: BIS_COLLECTION_UTILITIES.put_line(' ');
86: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_PDUE_F');
87:
88: FII_UTIL.Start_Timer;
89:
90: INSERT INTO isc_book_sum2_pdue_f(
91: INV_ORG_ID,
92: INVENTORY_ITEM_ID,

Line 129: FII_UTIL.Stop_Timer;

125: WHERE time_schedule_date_id < trunc(sysdate);
126:
127: l_row_count := l_row_count + sql%rowcount;
128:
129: FII_UTIL.Stop_Timer;
130: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_PDUE_F in');
131:
132: BIS_COLLECTION_UTILITIES.WRAPUP(
133: TRUE,

Line 130: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_PDUE_F in');

126:
127: l_row_count := l_row_count + sql%rowcount;
128:
129: FII_UTIL.Stop_Timer;
130: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_PDUE_F in');
131:
132: BIS_COLLECTION_UTILITIES.WRAPUP(
133: TRUE,
134: l_row_count,

Line 196: FII_UTIL.Start_Timer;

192: l_to_date := sysdate;
193:
194: BIS_COLLECTION_UTILITIES.put_line('Updating ISC_BOOK_SUM2_PDUE2_F');
195:
196: FII_UTIL.Start_Timer;
197:
198: UPDATE isc_book_sum2_pdue2_f
199: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
200: WHERE time_snapshot_date_id = trunc(sysdate);

Line 202: FII_UTIL.Stop_Timer;

198: UPDATE isc_book_sum2_pdue2_f
199: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
200: WHERE time_snapshot_date_id = trunc(sysdate);
201:
202: FII_UTIL.Stop_Timer;
203: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_PDUE2_F in');
204:
205: BIS_COLLECTION_UTILITIES.put_line(' ');
206: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_PDUE2_F');

Line 203: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_PDUE2_F in');

199: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
200: WHERE time_snapshot_date_id = trunc(sysdate);
201:
202: FII_UTIL.Stop_Timer;
203: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_PDUE2_F in');
204:
205: BIS_COLLECTION_UTILITIES.put_line(' ');
206: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_PDUE2_F');
207:

Line 208: FII_UTIL.Start_Timer;

204:
205: BIS_COLLECTION_UTILITIES.put_line(' ');
206: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_PDUE2_F');
207:
208: FII_UTIL.Start_Timer;
209:
210: INSERT INTO isc_book_sum2_pdue2_f(
211: INV_ORG_ID,
212: INVENTORY_ITEM_ID,

Line 265: FII_UTIL.Stop_Timer;

261: WHERE (time_schedule_date_id < trunc(sysdate) OR time_promise_date_id < trunc(sysdate));
262:
263: l_row_count := l_row_count + sql%rowcount;
264:
265: FII_UTIL.Stop_Timer;
266: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_PDUE2_F in');
267:
268: BIS_COLLECTION_UTILITIES.WRAPUP(
269: TRUE,

Line 266: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_PDUE2_F in');

262:
263: l_row_count := l_row_count + sql%rowcount;
264:
265: FII_UTIL.Stop_Timer;
266: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_PDUE2_F in');
267:
268: BIS_COLLECTION_UTILITIES.WRAPUP(
269: TRUE,
270: l_row_count,

Line 332: FII_UTIL.Start_Timer;

328: l_to_date := sysdate;
329:
330: BIS_COLLECTION_UTILITIES.put_line('Updating ISC_BOOK_SUM2_BKORD_F');
331:
332: FII_UTIL.Start_Timer;
333:
334: UPDATE isc_book_sum2_bkord_f
335: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
336: WHERE time_snapshot_date_id = trunc(sysdate);

Line 338: FII_UTIL.Stop_Timer;

334: UPDATE isc_book_sum2_bkord_f
335: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
336: WHERE time_snapshot_date_id = trunc(sysdate);
337:
338: FII_UTIL.Stop_Timer;
339: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_BKORD_F in');
340:
341: BIS_COLLECTION_UTILITIES.put_line(' ');
342: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_BKORD_F');

Line 339: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_BKORD_F in');

335: SET time_snapshot_date_id = to_date('1000/01/01 00:00:00','YYYY/MM/DD HH24:MI:SS')
336: WHERE time_snapshot_date_id = trunc(sysdate);
337:
338: FII_UTIL.Stop_Timer;
339: FII_UTIL.Print_Timer('Obsoleted ' || sql%rowcount || ' rows in ISC_BOOK_SUM2_BKORD_F in');
340:
341: BIS_COLLECTION_UTILITIES.put_line(' ');
342: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_BKORD_F');
343:

Line 344: FII_UTIL.Start_Timer;

340:
341: BIS_COLLECTION_UTILITIES.put_line(' ');
342: BIS_COLLECTION_UTILITIES.put_line('Inserting data into ISC_BOOK_SUM2_BKORD_F');
343:
344: FII_UTIL.Start_Timer;
345:
346: INSERT INTO isc_book_sum2_bkord_f(
347: INV_ORG_ID,
348: INVENTORY_ITEM_ID,

Line 398: FII_UTIL.Stop_Timer;

394: AND fact.charge_periodicity_code is NULL;
395:
396: l_row_count := l_row_count + sql%rowcount;
397:
398: FII_UTIL.Stop_Timer;
399: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_BKORD_F in');
400:
401: BIS_COLLECTION_UTILITIES.WRAPUP(
402: TRUE,

Line 399: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_BKORD_F in');

395:
396: l_row_count := l_row_count + sql%rowcount;
397:
398: FII_UTIL.Stop_Timer;
399: FII_UTIL.Print_Timer('Inserted ' || l_row_count || ' rows into ISC_BOOK_SUM2_BKORD_F in');
400:
401: BIS_COLLECTION_UTILITIES.WRAPUP(
402: TRUE,
403: l_row_count,