[Home] [Help]
[Dependency Information]
Object Name: | EAM_METERS |
---|---|
Object Type: | TABLE |
Owner: | EAM |
FND Design Data: | ![]() |
Subobject Name: | |
Status: | VALID |
This table stores meter templates and meter definitions used in EAM preventive maintenance. When tmpl_flag='Y', the row is a meter template. When tmpl_flag='N' or is null, the row is a meter definition.
Tablespace: | ![]() |
---|---|
PCT Free: | 10 |
PCT Used: |
Index | Type | Uniqueness | Tablespace | Column |
---|---|---|---|---|
EAM_METERS_U1 | NORMAL | UNIQUE |
![]() |
![]() |
EAM_METERS_U2 | NORMAL | UNIQUE |
![]() |
![]() |
Name | Datatype | Length | Mandatory | Comments |
---|---|---|---|---|
METER_ID | NUMBER | Yes | Meter identifier | |
METER_NAME | VARCHAR2 | (50) | Yes | Meter Name |
METER_UOM | VARCHAR2 | (3) | Yes | Meter's Unit of measure |
VALUE_CHANGE_DIR | NUMBER | Value Change Direction | ||
USED_IN_SCHEDULING | VARCHAR2 | (1) | Used in Scheduling Flag | |
USER_DEFINED_RATE | NUMBER | Usage Rate | ||
USE_PAST_READING | NUMBER | Indicator of how many past reading should be used to compute rate | ||
DESCRIPTION | VARCHAR2 | (240) | Meter description | |
FROM_EFFECTIVE_DATE | DATE | Effective start date | ||
TO_EFFECTIVE_DATE | DATE | Effective end date | ||
CREATED_BY | NUMBER | Yes | Standard Who Column | |
CREATION_DATE | DATE | Yes | Standard Who Column | |
LAST_UPDATE_LOGIN | NUMBER | Standard Who Column | ||
LAST_UPDATE_DATE | DATE | Yes | Standard Who Column | |
LAST_UPDATED_BY | NUMBER | Yes | Standard Who Column | |
ATTRIBUTE_CATEGORY | VARCHAR2 | (30) | Descriptive Flexfield Column | |
ATTRIBUTE1 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE2 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE3 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE4 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE5 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE6 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE7 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE8 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE9 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE10 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE11 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE12 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE13 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE14 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
ATTRIBUTE15 | VARCHAR2 | (150) | Descriptive Flexfield Column | |
TMPL_FLAG | VARCHAR2 | (1) | Flag indicating a meter template | |
SOURCE_TMPL_ID | NUMBER | The meter template that the meter is created from | ||
INITIAL_READING | NUMBER | The first meter reading upon meter creation | ||
METER_TYPE | NUMBER | (1) | Meter type. 1 indicates absolute meter, 2 indicates change meter | |
MIGRATED_FLAG | VARCHAR2 | (1) | Flag indicating whether the record has been migrated | |
REQUIRED_FLAG | VARCHAR2 | (1) | Flag indicating whether the meter reading entry is required during work order completion |
Cut, paste (and edit) the following text to query this object:
SELECT METER_ID
, METER_NAME
, METER_UOM
, VALUE_CHANGE_DIR
, USED_IN_SCHEDULING
, USER_DEFINED_RATE
, USE_PAST_READING
, DESCRIPTION
, FROM_EFFECTIVE_DATE
, TO_EFFECTIVE_DATE
, CREATED_BY
, CREATION_DATE
, LAST_UPDATE_LOGIN
, LAST_UPDATE_DATE
, LAST_UPDATED_BY
, ATTRIBUTE_CATEGORY
, ATTRIBUTE1
, ATTRIBUTE2
, ATTRIBUTE3
, ATTRIBUTE4
, ATTRIBUTE5
, ATTRIBUTE6
, ATTRIBUTE7
, ATTRIBUTE8
, ATTRIBUTE9
, ATTRIBUTE10
, ATTRIBUTE11
, ATTRIBUTE12
, ATTRIBUTE13
, ATTRIBUTE14
, ATTRIBUTE15
, TMPL_FLAG
, SOURCE_TMPL_ID
, INITIAL_READING
, METER_TYPE
, MIGRATED_FLAG
, REQUIRED_FLAG
FROM EAM.EAM_METERS;
EAM.EAM_METERS does not reference any database object