DBA Data[Home] [Help]

APPS.HRDPP_UPDATE_PLAN_TYPE SQL Statements

The following lines contain the word 'select', 'insert', 'update' or 'delete':

Line: 66

insert into hr_pump_batch_line_user_keys
(user_key_id, batch_line_id,user_key_value,unique_key_id)
values
(hr_pump_batch_line_user_keys_s.nextval,
p_batch_line_id,
p_user_key_value,
p_unique_key_id);
Line: 76

procedure insert_batch_lines
(p_batch_id      in number
,p_data_pump_batch_line_id in number default null
,p_data_pump_business_grp_name in varchar2 default null
,p_user_sequence in number default null
,p_link_value    in number default null
,P_NAME in varchar2 default null
,P_MX_ENRL_ALWD_NUM in number default null
,I_MX_ENRL_ALWD_NUM in varchar2 default 'N'
,P_MN_ENRL_RQD_NUM in number default null
,I_MN_ENRL_RQD_NUM in varchar2 default 'N'
,P_PL_TYP_STAT_CD in varchar2 default null
,P_OPT_TYP_CD in varchar2 default null
,P_OPT_DSPLY_FMT_CD in varchar2 default null
,P_COMP_TYP_CD in varchar2 default null
,P_IVR_IDENT in varchar2 default null
,P_NO_MX_ENRL_NUM_DFND_FLAG in varchar2 default null
,P_NO_MN_ENRL_NUM_DFND_FLAG in varchar2 default null
,P_PTP_ATTRIBUTE_CATEGORY in varchar2 default null
,P_PTP_ATTRIBUTE1 in varchar2 default null
,P_PTP_ATTRIBUTE2 in varchar2 default null
,P_PTP_ATTRIBUTE3 in varchar2 default null
,P_PTP_ATTRIBUTE4 in varchar2 default null
,P_PTP_ATTRIBUTE5 in varchar2 default null
,P_PTP_ATTRIBUTE6 in varchar2 default null
,P_PTP_ATTRIBUTE7 in varchar2 default null
,P_PTP_ATTRIBUTE8 in varchar2 default null
,P_PTP_ATTRIBUTE9 in varchar2 default null
,P_PTP_ATTRIBUTE10 in varchar2 default null
,P_PTP_ATTRIBUTE11 in varchar2 default null
,P_PTP_ATTRIBUTE12 in varchar2 default null
,P_PTP_ATTRIBUTE13 in varchar2 default null
,P_PTP_ATTRIBUTE14 in varchar2 default null
,P_PTP_ATTRIBUTE15 in varchar2 default null
,P_PTP_ATTRIBUTE16 in varchar2 default null
,P_PTP_ATTRIBUTE17 in varchar2 default null
,P_PTP_ATTRIBUTE18 in varchar2 default null
,P_PTP_ATTRIBUTE19 in varchar2 default null
,P_PTP_ATTRIBUTE20 in varchar2 default null
,P_PTP_ATTRIBUTE21 in varchar2 default null
,P_PTP_ATTRIBUTE22 in varchar2 default null
,P_PTP_ATTRIBUTE23 in varchar2 default null
,P_PTP_ATTRIBUTE24 in varchar2 default null
,P_PTP_ATTRIBUTE25 in varchar2 default null
,P_PTP_ATTRIBUTE26 in varchar2 default null
,P_PTP_ATTRIBUTE27 in varchar2 default null
,P_PTP_ATTRIBUTE28 in varchar2 default null
,P_PTP_ATTRIBUTE29 in varchar2 default null
,P_PTP_ATTRIBUTE30 in varchar2 default null
,P_EFFECTIVE_DATE in date
,P_DATETRACK_MODE in varchar2
,P_SHORT_NAME in varchar2 default null
,P_SHORT_CODE in varchar2 default null
,P_LEGISLATION_CODE in varchar2 default null
,P_LEGISLATION_SUBGROUP in varchar2 default null
,P_PLAN_TYPE in varchar2) is
blid number := p_data_pump_batch_line_id;
Line: 135

delete from hr_pump_batch_lines where batch_line_id = blid;
Line: 136

delete from hr_pump_batch_exceptions
where source_type = 'BATCH_LINE' and source_id = blid;
Line: 139

insert into hr_pump_batch_lines
(batch_id
,batch_line_id
,business_group_name
,api_module_id
,line_status
,user_sequence
,link_value
,pval003
,pval004
,pval005
,pval006
,pval007
,pval008
,pval009
,pval010
,pval011
,pval012
,pval013
,pval014
,pval015
,pval016
,pval017
,pval018
,pval019
,pval020
,pval021
,pval022
,pval023
,pval024
,pval025
,pval026
,pval027
,pval028
,pval029
,pval030
,pval031
,pval032
,pval033
,pval034
,pval035
,pval036
,pval037
,pval038
,pval039
,pval040
,pval041
,pval042
,pval043
,pval044
,pval045
,pval046
,pval047
,pval048
,pval049
,pval050)
values
(p_batch_id
,nvl(blid,hr_pump_batch_lines_s.nextval)
,p_data_pump_business_grp_name
,710
,'U'
,p_user_sequence
,p_link_value
,P_NAME
,nd(P_MX_ENRL_ALWD_NUM,I_MX_ENRL_ALWD_NUM)
,nd(P_MN_ENRL_RQD_NUM,I_MN_ENRL_RQD_NUM)
,P_PL_TYP_STAT_CD
,P_OPT_TYP_CD
,P_OPT_DSPLY_FMT_CD
,P_COMP_TYP_CD
,P_IVR_IDENT
,P_NO_MX_ENRL_NUM_DFND_FLAG
,P_NO_MN_ENRL_NUM_DFND_FLAG
,P_PTP_ATTRIBUTE_CATEGORY
,P_PTP_ATTRIBUTE1
,P_PTP_ATTRIBUTE2
,P_PTP_ATTRIBUTE3
,P_PTP_ATTRIBUTE4
,P_PTP_ATTRIBUTE5
,P_PTP_ATTRIBUTE6
,P_PTP_ATTRIBUTE7
,P_PTP_ATTRIBUTE8
,P_PTP_ATTRIBUTE9
,P_PTP_ATTRIBUTE10
,P_PTP_ATTRIBUTE11
,P_PTP_ATTRIBUTE12
,P_PTP_ATTRIBUTE13
,P_PTP_ATTRIBUTE14
,P_PTP_ATTRIBUTE15
,P_PTP_ATTRIBUTE16
,P_PTP_ATTRIBUTE17
,P_PTP_ATTRIBUTE18
,P_PTP_ATTRIBUTE19
,P_PTP_ATTRIBUTE20
,P_PTP_ATTRIBUTE21
,P_PTP_ATTRIBUTE22
,P_PTP_ATTRIBUTE23
,P_PTP_ATTRIBUTE24
,P_PTP_ATTRIBUTE25
,P_PTP_ATTRIBUTE26
,P_PTP_ATTRIBUTE27
,P_PTP_ATTRIBUTE28
,P_PTP_ATTRIBUTE29
,P_PTP_ATTRIBUTE30
,dc(P_EFFECTIVE_DATE)
,P_DATETRACK_MODE
,P_SHORT_NAME
,P_SHORT_CODE
,P_LEGISLATION_CODE
,P_LEGISLATION_SUBGROUP
,P_PLAN_TYPE);
Line: 251

end insert_batch_lines;
Line: 257

select l.rowid myrowid,
decode(l.pval001,cn,dn,d(l.pval001)) p1,
decode(l.pval002,cn,dn,d(l.pval002)) p2,
decode(l.pval003,cn,vn,vn,vh,l.pval003) p3,
l.pval003 d3,
decode(l.pval004,cn,nn,vn,nh,n(l.pval004)) p4,
l.pval004 d4,
decode(l.pval005,cn,nn,vn,nh,n(l.pval005)) p5,
l.pval005 d5,
decode(l.pval006,cn,vn,vn,vh,
 hr_pump_get.gl(l.pval006,'BEN_STAT',d(l.pval044),vn)) p6,
l.pval006 d6,
decode(l.pval007,cn,vn,vn,vh,
 hr_pump_get.gl(l.pval007,'BEN_OPT_TYP',d(l.pval044),vn)) p7,
l.pval007 d7,
decode(l.pval008,cn,vn,vn,vh,
 hr_pump_get.gl(l.pval008,'BEN_OPT_DSPLY_FMT',d(l.pval044),vn)) p8,
l.pval008 d8,
decode(l.pval009,cn,vn,vn,vh,
 hr_pump_get.gl(l.pval009,'BEN_COMP_TYP',d(l.pval044),vn)) p9,
l.pval009 d9,
decode(l.pval010,cn,vn,vn,vh,l.pval010) p10,
l.pval010 d10,
decode(l.pval011,cn,vn,vn,vh,
 hr_pump_get.gl(l.pval011,'YES_NO',d(l.pval044),vn)) p11,
l.pval011 d11,
decode(l.pval012,cn,vn,vn,vh,
 hr_pump_get.gl(l.pval012,'YES_NO',d(l.pval044),vn)) p12,
l.pval012 d12,
decode(l.pval013,cn,vn,vn,vh,l.pval013) p13,
l.pval013 d13,
decode(l.pval014,cn,vn,vn,vh,l.pval014) p14,
l.pval014 d14,
decode(l.pval015,cn,vn,vn,vh,l.pval015) p15,
l.pval015 d15,
decode(l.pval016,cn,vn,vn,vh,l.pval016) p16,
l.pval016 d16,
decode(l.pval017,cn,vn,vn,vh,l.pval017) p17,
l.pval017 d17,
decode(l.pval018,cn,vn,vn,vh,l.pval018) p18,
l.pval018 d18,
decode(l.pval019,cn,vn,vn,vh,l.pval019) p19,
l.pval019 d19,
decode(l.pval020,cn,vn,vn,vh,l.pval020) p20,
l.pval020 d20,
decode(l.pval021,cn,vn,vn,vh,l.pval021) p21,
l.pval021 d21,
decode(l.pval022,cn,vn,vn,vh,l.pval022) p22,
l.pval022 d22,
decode(l.pval023,cn,vn,vn,vh,l.pval023) p23,
l.pval023 d23,
decode(l.pval024,cn,vn,vn,vh,l.pval024) p24,
l.pval024 d24,
decode(l.pval025,cn,vn,vn,vh,l.pval025) p25,
l.pval025 d25,
decode(l.pval026,cn,vn,vn,vh,l.pval026) p26,
l.pval026 d26,
decode(l.pval027,cn,vn,vn,vh,l.pval027) p27,
l.pval027 d27,
decode(l.pval028,cn,vn,vn,vh,l.pval028) p28,
l.pval028 d28,
decode(l.pval029,cn,vn,vn,vh,l.pval029) p29,
l.pval029 d29,
decode(l.pval030,cn,vn,vn,vh,l.pval030) p30,
l.pval030 d30,
decode(l.pval031,cn,vn,vn,vh,l.pval031) p31,
l.pval031 d31,
decode(l.pval032,cn,vn,vn,vh,l.pval032) p32,
l.pval032 d32,
decode(l.pval033,cn,vn,vn,vh,l.pval033) p33,
l.pval033 d33,
decode(l.pval034,cn,vn,vn,vh,l.pval034) p34,
l.pval034 d34,
decode(l.pval035,cn,vn,vn,vh,l.pval035) p35,
l.pval035 d35,
decode(l.pval036,cn,vn,vn,vh,l.pval036) p36,
l.pval036 d36,
decode(l.pval037,cn,vn,vn,vh,l.pval037) p37,
l.pval037 d37,
decode(l.pval038,cn,vn,vn,vh,l.pval038) p38,
l.pval038 d38,
decode(l.pval039,cn,vn,vn,vh,l.pval039) p39,
l.pval039 d39,
decode(l.pval040,cn,vn,vn,vh,l.pval040) p40,
l.pval040 d40,
decode(l.pval041,cn,vn,vn,vh,l.pval041) p41,
l.pval041 d41,
decode(l.pval042,cn,vn,vn,vh,l.pval042) p42,
l.pval042 d42,
decode(l.pval043,cn,vn,vn,vh,l.pval043) p43,
l.pval043 d43,
decode(l.pval044,cn,dn,d(l.pval044)) p44,
decode(l.pval045,cn,vn,l.pval045) p45,
decode(l.pval046,cn,vn,vn,vh,l.pval046) p46,
l.pval046 d46,
decode(l.pval047,cn,vn,vn,vh,l.pval047) p47,
l.pval047 d47,
decode(l.pval048,cn,vn,vn,vh,l.pval048) p48,
l.pval048 d48,
decode(l.pval049,cn,vn,vn,vh,l.pval049) p49,
l.pval049 d49,
decode(l.pval050,cn,vn,l.pval050) p50
from hr_pump_batch_lines l
where l.batch_line_id = p_batch_line_id;
Line: 402

ben_plan_type_api.UPDATE_PLAN_TYPE
(p_validate => l_validate
,P_PL_TYP_ID => L_PL_TYP_ID
,P_EFFECTIVE_START_DATE => c.p1
,P_EFFECTIVE_END_DATE => c.p2
,P_NAME => c.p3
,P_MX_ENRL_ALWD_NUM => c.p4
,P_MN_ENRL_RQD_NUM => c.p5
,P_PL_TYP_STAT_CD => c.p6
,P_OPT_TYP_CD => c.p7
,P_OPT_DSPLY_FMT_CD => c.p8
,P_COMP_TYP_CD => c.p9
,P_IVR_IDENT => c.p10
,P_NO_MX_ENRL_NUM_DFND_FLAG => c.p11
,P_NO_MN_ENRL_NUM_DFND_FLAG => c.p12
,p_business_group_id => p_business_group_id
,P_PTP_ATTRIBUTE_CATEGORY => c.p13
,P_PTP_ATTRIBUTE1 => c.p14
,P_PTP_ATTRIBUTE2 => c.p15
,P_PTP_ATTRIBUTE3 => c.p16
,P_PTP_ATTRIBUTE4 => c.p17
,P_PTP_ATTRIBUTE5 => c.p18
,P_PTP_ATTRIBUTE6 => c.p19
,P_PTP_ATTRIBUTE7 => c.p20
,P_PTP_ATTRIBUTE8 => c.p21
,P_PTP_ATTRIBUTE9 => c.p22
,P_PTP_ATTRIBUTE10 => c.p23
,P_PTP_ATTRIBUTE11 => c.p24
,P_PTP_ATTRIBUTE12 => c.p25
,P_PTP_ATTRIBUTE13 => c.p26
,P_PTP_ATTRIBUTE14 => c.p27
,P_PTP_ATTRIBUTE15 => c.p28
,P_PTP_ATTRIBUTE16 => c.p29
,P_PTP_ATTRIBUTE17 => c.p30
,P_PTP_ATTRIBUTE18 => c.p31
,P_PTP_ATTRIBUTE19 => c.p32
,P_PTP_ATTRIBUTE20 => c.p33
,P_PTP_ATTRIBUTE21 => c.p34
,P_PTP_ATTRIBUTE22 => c.p35
,P_PTP_ATTRIBUTE23 => c.p36
,P_PTP_ATTRIBUTE24 => c.p37
,P_PTP_ATTRIBUTE25 => c.p38
,P_PTP_ATTRIBUTE26 => c.p39
,P_PTP_ATTRIBUTE27 => c.p40
,P_PTP_ATTRIBUTE28 => c.p41
,P_PTP_ATTRIBUTE29 => c.p42
,P_PTP_ATTRIBUTE30 => c.p43
,P_OBJECT_VERSION_NUMBER => L_OBJECT_VERSION_NUMBER
,P_EFFECTIVE_DATE => c.p44
,P_DATETRACK_MODE => c.p45
,P_SHORT_NAME => c.p46
,P_SHORT_CODE => c.p47
,P_LEGISLATION_CODE => c.p48
,P_LEGISLATION_SUBGROUP => c.p49);
Line: 459

update hr_pump_batch_lines l set
l.pval001 = decode(c.p1,null,cn,dc(c.p1)),
l.pval002 = decode(c.p2,null,cn,dc(c.p2))
where l.rowid = c.myrowid;