DBA Data[Home] [Help]

APPS.BSC_DIM_FILTERS_PVT dependencies on FND_API

Line 84: x_return_status := FND_API.G_RET_STS_SUCCESS;

80: SAVEPOINT CheckFiltersNotApplyPvt;
81: --DBMS_OUTPUT.PUT_LINE('BEGIN Check_Filters_Not_Apply' );
82: ----DBMS_OUTPUT.PUT_LINE('Check_Filters_Not_Apply p_Tab_Id = ' || p_Tab_Id );
83:
84: x_return_status := FND_API.G_RET_STS_SUCCESS;
85:
86: IF (p_Tab_Id IS NOT NULL) THEN
87: -- Find Tab Dim Levels
88: OPEN c_Filters_Not_Apply;

Line 113: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN

109: CLOSE c_Filters_Not_Apply;
110: END IF;
111: ----DBMS_OUTPUT.PUT_LINE('END Check_Filters_Not_Apply' );
112: EXCEPTION
113: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
114: IF (c_Filters_Not_Apply%ISOPEN) THEN
115: CLOSE c_Filters_Not_Apply;
116: END IF;
117: ROLLBACK TO CheckFiltersNotApplyPvt;

Line 118: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

114: IF (c_Filters_Not_Apply%ISOPEN) THEN
115: CLOSE c_Filters_Not_Apply;
116: END IF;
117: ROLLBACK TO CheckFiltersNotApplyPvt;
118: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
119: FND_MSG_PUB.COUNT_And_Get
120: ( p_encoded => FND_API.G_FALSE
121: , p_COUNT => x_msg_COUNT
122: , p_data => x_msg_data

Line 120: ( p_encoded => FND_API.G_FALSE

116: END IF;
117: ROLLBACK TO CheckFiltersNotApplyPvt;
118: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
119: FND_MSG_PUB.COUNT_And_Get
120: ( p_encoded => FND_API.G_FALSE
121: , p_COUNT => x_msg_COUNT
122: , p_data => x_msg_data
123: );
124: RAISE;

Line 130: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

126: IF (c_Filters_Not_Apply%ISOPEN) THEN
127: CLOSE c_Filters_Not_Apply;
128: END IF;
129: ROLLBACK TO CheckFiltersNotApplyPvt;
130: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
131: FND_MSG_PUB.COUNT_And_Get
132: ( p_encoded => FND_API.G_FALSE
133: , p_COUNT => x_msg_COUNT
134: , p_data => x_msg_data

Line 132: ( p_encoded => FND_API.G_FALSE

128: END IF;
129: ROLLBACK TO CheckFiltersNotApplyPvt;
130: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
131: FND_MSG_PUB.COUNT_And_Get
132: ( p_encoded => FND_API.G_FALSE
133: , p_COUNT => x_msg_COUNT
134: , p_data => x_msg_data
135: );
136: RAISE;

Line 180: x_return_status := FND_API.G_RET_STS_SUCCESS;

176: --DBMS_OUTPUT.PUT_LINE('BEGIN Drop_Filter' );
177: --DBMS_OUTPUT.PUT_LINE('Drop_Filter p_Tab_Id = ' || p_Tab_Id );
178: --DBMS_OUTPUT.PUT_LINE('Drop_Filter p_Dim_Level_Id = ' || p_Dim_Level_Id );
179:
180: x_return_status := FND_API.G_RET_STS_SUCCESS;
181:
182: l_Filter_Level_View_Name := BSC_DIM_FILTERS_PVT.Get_Filter_View_Name(p_Tab_Id, p_Dim_Level_Id);
183:
184: --DBMS_OUTPUT.PUT_LINE(' Drop_Filter l_Filter_Level_View_Name = ' || l_Filter_Level_View_Name );

Line 235: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN

231: END IF;
232:
233: --DBMS_OUTPUT.PUT_LINE('END Drop_Filter p_Tab_Id = ' || p_Tab_Id || ' p_Dim_Level_Id = ' || p_Dim_Level_Id );
234: EXCEPTION
235: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
236: IF (c_child_dim_obj%ISOPEN) THEN
237: CLOSE c_child_dim_obj;
238: END IF;
239: ROLLBACK TO BcsFiltersPubDeleteFilterView;

Line 240: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

236: IF (c_child_dim_obj%ISOPEN) THEN
237: CLOSE c_child_dim_obj;
238: END IF;
239: ROLLBACK TO BcsFiltersPubDeleteFilterView;
240: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
241: FND_MSG_PUB.COUNT_And_Get
242: ( p_encoded => FND_API.G_FALSE
243: , p_COUNT => x_msg_COUNT
244: , p_data => x_msg_data

Line 242: ( p_encoded => FND_API.G_FALSE

238: END IF;
239: ROLLBACK TO BcsFiltersPubDeleteFilterView;
240: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
241: FND_MSG_PUB.COUNT_And_Get
242: ( p_encoded => FND_API.G_FALSE
243: , p_COUNT => x_msg_COUNT
244: , p_data => x_msg_data
245: );
246: RAISE;

Line 252: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

248: IF (c_child_dim_obj%ISOPEN) THEN
249: CLOSE c_child_dim_obj;
250: END IF;
251: ROLLBACK TO BcsFiltersPubDeleteFilterView;
252: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
253: IF (x_msg_data IS NOT NULL) THEN
254: x_msg_data := x_msg_data||' -> BSC_DIM_FILTERS_PVT.Drop_Filter';
255: ELSE
256: x_msg_data := SQLERRM||' at BSC_DIM_FILTERS_PVT.Drop_Filter';

Line 282: x_return_status := FND_API.G_RET_STS_SUCCESS;

278: ----DBMS_OUTPUT.PUT_LINE('BEGIN Drop_Filter' );
279: ----DBMS_OUTPUT.PUT_LINE('Drop_Filter p_Tab_Id = ' || p_Tab_Id );
280: ----DBMS_OUTPUT.PUT_LINE('Drop_Filter p_Dim_Level_Id = ' || p_Dim_Level_Id );
281:
282: x_return_status := FND_API.G_RET_STS_SUCCESS;
283: -- Save point for the current filters view
284: SAVEPOINT BcsFiltersPvtDeleteFilterView;
285:
286: l_Filter_Level_View_Name := Get_Filter_View_Name(p_Tab_Id, p_Dim_Level_Id);

Line 345: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN

341: END IF;
342:
343: ----DBMS_OUTPUT.PUT_LINE('END Drop_Filter p_Tab_Id = ' || p_Tab_Id || ' p_Dim_Level_Id = ' || p_Dim_Level_Id );
344: EXCEPTION
345: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
346: ROLLBACK TO BcsFiltersPvtDeleteFilterView;
347: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
348: FND_MSG_PUB.COUNT_And_Get
349: ( p_encoded => FND_API.G_FALSE

Line 347: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

343: ----DBMS_OUTPUT.PUT_LINE('END Drop_Filter p_Tab_Id = ' || p_Tab_Id || ' p_Dim_Level_Id = ' || p_Dim_Level_Id );
344: EXCEPTION
345: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
346: ROLLBACK TO BcsFiltersPvtDeleteFilterView;
347: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
348: FND_MSG_PUB.COUNT_And_Get
349: ( p_encoded => FND_API.G_FALSE
350: , p_COUNT => x_msg_COUNT
351: , p_data => x_msg_data

Line 349: ( p_encoded => FND_API.G_FALSE

345: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
346: ROLLBACK TO BcsFiltersPvtDeleteFilterView;
347: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
348: FND_MSG_PUB.COUNT_And_Get
349: ( p_encoded => FND_API.G_FALSE
350: , p_COUNT => x_msg_COUNT
351: , p_data => x_msg_data
352: );
353: RAISE;

Line 356: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

352: );
353: RAISE;
354: WHEN OTHERS THEN
355: ROLLBACK TO BcsFiltersPvtDeleteFilterView;
356: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
357: IF (x_msg_data IS NOT NULL) THEN
358: x_msg_data := x_msg_data||' -> BSC_DIM_FILTERS_PVT.Drop_Filter_Objects';
359: ELSE
360: x_msg_data := SQLERRM||' at BSC_DIM_FILTERS_PVT.Drop_Filter_Objects';

Line 422: x_return_status := FND_API.G_RET_STS_SUCCESS;

418: AND KD.Level_View_Name <> SD.Level_View_Name;
419:
420: BEGIN
421:
422: x_return_status := FND_API.G_RET_STS_SUCCESS;
423: SAVEPOINT BcsFiltersPvtSynchKpiDim;
424: ----DBMS_OUTPUT.PUT_LINE('BEGIN Synch_Fiters_And_Kpi_Dim' );
425:
426: IF p_Tab_Id IS NOT NULL THEN

Line 494: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN

490: END IF;
491:
492: ----DBMS_OUTPUT.PUT_LINE('END Synch_Fiters_And_Kpi_Dim' );
493: EXCEPTION
494: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
495: IF (c_Kpi_Dim_Obj_To_Synch%ISOPEN) THEN
496: CLOSE c_Kpi_Dim_Obj_To_Synch;
497: END IF;
498: IF (c_Kpi_Dim_Obj_To_Synch2%ISOPEN) THEN

Line 502: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

498: IF (c_Kpi_Dim_Obj_To_Synch2%ISOPEN) THEN
499: CLOSE c_Kpi_Dim_Obj_To_Synch;
500: END IF;
501: ROLLBACK TO BcsFiltersPvtSynchKpiDim;
502: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
503: FND_MSG_PUB.COUNT_And_Get
504: ( p_encoded => FND_API.G_FALSE
505: , p_COUNT => x_msg_COUNT
506: , p_data => x_msg_data

Line 504: ( p_encoded => FND_API.G_FALSE

500: END IF;
501: ROLLBACK TO BcsFiltersPvtSynchKpiDim;
502: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
503: FND_MSG_PUB.COUNT_And_Get
504: ( p_encoded => FND_API.G_FALSE
505: , p_COUNT => x_msg_COUNT
506: , p_data => x_msg_data
507: );
508: RAISE;

Line 517: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;

513: IF (c_Kpi_Dim_Obj_To_Synch%ISOPEN) THEN
514: CLOSE c_Kpi_Dim_Obj_To_Synch2;
515: END IF;
516: ROLLBACK TO BcsFiltersPvtSynchKpiDim;
517: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
518: IF (x_msg_data IS NOT NULL) THEN
519: x_msg_data := x_msg_data ||' -> BSC_DIM_FILTERS_PVT.Synch_Fiters_And_Kpi_Dim ';
520: ELSE
521: x_msg_data := SQLERRM ||' at BSC_DIM_FILTERS_PVT.Synch_Fiters_And_Kpi_Dim ';