DBA Data[Home] [Help]

APPS.OTA_TAV_SHD dependencies on OTA_ACTIVITY_VERSIONS

Line 36: If (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK1') Then

32: --
33: Begin
34: hr_utility.set_location('Entering:'||l_proc, 5);
35: --
36: If (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK1') Then
37: fnd_message.set_name('OTA', 'OTA_13292_TAV_NO_TAD');
38: fnd_message.raise_error;
39: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK2') Then
40: fnd_message.set_name('OTA', 'OTA_13293_TAV_NO_SUP');

Line 39: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK2') Then

35: --
36: If (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK1') Then
37: fnd_message.set_name('OTA', 'OTA_13292_TAV_NO_TAD');
38: fnd_message.raise_error;
39: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK2') Then
40: fnd_message.set_name('OTA', 'OTA_13293_TAV_NO_SUP');
41: fnd_message.raise_error;
42: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK3') Then
43: fnd_message.set_name('OTA', 'OTA_13294_TAV_NO_DEV');

Line 42: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK3') Then

38: fnd_message.raise_error;
39: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK2') Then
40: fnd_message.set_name('OTA', 'OTA_13293_TAV_NO_SUP');
41: fnd_message.raise_error;
42: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_FK3') Then
43: fnd_message.set_name('OTA', 'OTA_13294_TAV_NO_DEV');
44: fnd_message.raise_error;
45: ElsIf (p_constraint_name = 'OTA_TAV_MAX_INTERNAL_MAX_ORDER') Then
46: fnd_message.set_name('OTA', 'OTA_13385_TAV_MAX_INT_ATTS');

Line 71: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_PK') Then

67: fnd_message.raise_error;
68: ElsIf (p_constraint_name = 'OTA_TAV_VERS_START_END_ORDER') Then
69: fnd_message.set_name('OTA', 'OTA_13312_GEN_DATE_ORDER');
70: fnd_message.raise_error;
71: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_PK') Then
72: hr_utility.set_message(801, 'HR_6153_ALL_PROCEDURE_FAIL');
73: hr_utility.set_message_token('PROCEDURE', l_proc);
74: hr_utility.set_message_token('STEP','5');
75: hr_utility.raise_error;

Line 76: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK2') Then

72: hr_utility.set_message(801, 'HR_6153_ALL_PROCEDURE_FAIL');
73: hr_utility.set_message_token('PROCEDURE', l_proc);
74: hr_utility.set_message_token('STEP','5');
75: hr_utility.raise_error;
76: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK2') Then
77: fnd_message.set_name('OTA', 'OTA_13301_TAV_DUPLICATE');
78: fnd_message.raise_error;
79: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK4') Then
80: fnd_message.set_name('OTA', 'OTA_13694_TAV_DUPLICATE');

Line 79: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK4') Then

75: hr_utility.raise_error;
76: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK2') Then
77: fnd_message.set_name('OTA', 'OTA_13301_TAV_DUPLICATE');
78: fnd_message.raise_error;
79: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK4') Then
80: fnd_message.set_name('OTA', 'OTA_13694_TAV_DUPLICATE');
81: fnd_message.raise_error;
82: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK5') Then
83: fnd_message.set_name('OTA', 'OTA_TAV_DUPLICATE_RCO');

Line 82: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK5') Then

78: fnd_message.raise_error;
79: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK4') Then
80: fnd_message.set_name('OTA', 'OTA_13694_TAV_DUPLICATE');
81: fnd_message.raise_error;
82: ElsIf (p_constraint_name = 'OTA_ACTIVITY_VERSIONS_UK5') Then
83: fnd_message.set_name('OTA', 'OTA_TAV_DUPLICATE_RCO');
84: fnd_message.raise_error;
85: Else
86: fnd_message.set_name('OTA','OTA_GEN_UNKN_CONSTRAINT');

Line 165: from ota_activity_versions

161: business_group_id,
162: data_source
163: ,competency_update_level
164:
165: from ota_activity_versions
166: where activity_version_id = p_activity_version_id;
167: --
168: l_proc varchar2(72) := g_package||'api_updating';
169: l_fct_ret boolean;

Line 291: from ota_activity_versions

287: business_group_id,
288: data_source
289: ,competency_update_level
290:
291: from ota_activity_versions
292: where activity_version_id = p_activity_version_id
293: for update nowait;
294: --
295: l_proc varchar2(72) := g_package||'lck';

Line 334: hr_utility.set_message_token('TABLE_NAME', 'ota_activity_versions');

330: -- The object is locked therefore we need to supply a meaningful
331: -- error message.
332: --
333: hr_utility.set_message(801, 'HR_7165_OBJECT_LOCKED');
334: hr_utility.set_message_token('TABLE_NAME', 'ota_activity_versions');
335: hr_utility.raise_error;
336: End lck;
337: --
338: -- ----------------------------------------------------------------------------