DBA Data[Home] [Help]

APPS.OKC_REP_UTIL_PVT dependencies on FND_FUNCTION

Line 553: IF ( p_function_name = G_UPDATE_ACCESS_LEVEL AND NOT( FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,'Y') OR FND_FUNCTION.TEST(G_FUNC_OKC_REP_USER_FUNC,'Y') ) ) THEN

549:
550: x_return_status := FND_API.G_RET_STS_SUCCESS;
551: x_has_access := FND_API.G_FALSE;
552:
553: IF ( p_function_name = G_UPDATE_ACCESS_LEVEL AND NOT( FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,'Y') OR FND_FUNCTION.TEST(G_FUNC_OKC_REP_USER_FUNC,'Y') ) ) THEN
554:
555: IF ( FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
556: FND_LOG.STRING( FND_LOG.LEVEL_STATEMENT ,G_MODULE||l_api_name,
557: 'returning FALSE, queried for UPDATE access, not an Admin, not a User, must be a Viewer');

Line 619: IF (FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,'Y')) THEN

615: FND_LOG.STRING( FND_LOG.LEVEL_STATEMENT ,G_MODULE||l_api_name,
616: 'checking OKC_REP_ADMINISTRATOR function: ' || G_FUNC_OKC_REP_ADMINISTRATOR);
617: END IF;
618:
619: IF (FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,'Y')) THEN
620:
621: x_has_access := FND_API.G_TRUE;
622:
623: IF ( FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

Line 625: 'IF (FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,''Y'')) THEN: TRUE: x_has_access = ' || x_has_access);

621: x_has_access := FND_API.G_TRUE;
622:
623: IF ( FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
624: FND_LOG.STRING( FND_LOG.LEVEL_STATEMENT ,G_MODULE||l_api_name,
625: 'IF (FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,''Y'')) THEN: TRUE: x_has_access = ' || x_has_access);
626: END IF;
627: ELSE
628:
629: -- Check if Use ACL flag is enabled for the current contract

Line 680: END IF; -- End of FND_FUNCTION.TEST() check

676: 'IF (l_use_acl_flag = ''Y'') THEN: FALSE: x_has_access = ' || x_has_access);
677: END IF;
678: END IF; -- End of Use ACL flag check
679:
680: END IF; -- End of FND_FUNCTION.TEST() check
681:
682: END IF; -- End of owner id check
683:
684: END IF; -- End of intent profile check

Line 6824: IF FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,'Y') OR FND_FUNCTION.TEST(G_FUNC_OKC_REP_USER_FUNC,'Y') THEN

6820: FND_LOG.STRING( FND_LOG.LEVEL_PROCEDURE ,G_MODULE||l_api_name,
6821: 'Entered Function OKC_REP_UTIL_PVT.can_update');
6822: END IF;
6823:
6824: IF FND_FUNCTION.TEST(G_FUNC_OKC_REP_ADMINISTRATOR,'Y') OR FND_FUNCTION.TEST(G_FUNC_OKC_REP_USER_FUNC,'Y') THEN
6825: l_can_update := 'Y';
6826: END IF;
6827:
6828: IF ( FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

Line 6878: IF FND_FUNCTION.TEST(G_FUNC_OKC_REP_SALES_WB_USER,'Y') THEN

6874: FND_LOG.STRING( FND_LOG.LEVEL_PROCEDURE ,G_MODULE||l_api_name,
6875: 'Entered Function OKC_REP_UTIL_PVT.is_sales_workbench');
6876: END IF;
6877:
6878: IF FND_FUNCTION.TEST(G_FUNC_OKC_REP_SALES_WB_USER,'Y') THEN
6879: l_is_sales_workbench := 'Y';
6880: END IF;
6881:
6882: IF ( FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN