DBA Data[Home] [Help]

APPS.CSFW_DEBRIEF_PUB dependencies on FND_MESSAGE

Line 209: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');

205: THEN
206: null;
207: ELSE
208: --convert the Server to Client time zone
209: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
210: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
211: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
212:
213: p_error := -21;

Line 210: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));

206: null;
207: ELSE
208: --convert the Server to Client time zone
209: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
210: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
211: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
212:
213: p_error := -21;
214: p_error := FND_MESSAGE.Get;

Line 211: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));

207: ELSE
208: --convert the Server to Client time zone
209: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
210: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
211: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
212:
213: p_error := -21;
214: p_error := FND_MESSAGE.Get;
215:

Line 214: p_error := FND_MESSAGE.Get;

210: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
211: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
212:
213: p_error := -21;
214: p_error := FND_MESSAGE.Get;
215:
216: RETURN ;
217: END IF;
218:

Line 225: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE_END');

221: THEN
222: null;
223: ELSE
224: --convert the Server to Client time zone
225: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE_END');
226: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
227: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
228:
229: p_error := -21;

Line 226: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));

222: null;
223: ELSE
224: --convert the Server to Client time zone
225: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE_END');
226: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
227: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
228:
229: p_error := -21;
230: p_error := FND_MESSAGE.Get;

Line 227: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));

223: ELSE
224: --convert the Server to Client time zone
225: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE_END');
226: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
227: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
228:
229: p_error := -21;
230: p_error := FND_MESSAGE.Get;
231:

Line 230: p_error := FND_MESSAGE.Get;

226: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
227: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
228:
229: p_error := -21;
230: p_error := FND_MESSAGE.Get;
231:
232: RETURN ;
233: END IF;
234: */

Line 237: FND_MESSAGE.Set_Name('CSF', 'CSFW_START_END_DATE_SAME');

233: END IF;
234: */
235:
236: IF (p_labor_start_date >= p_labor_end_date) THEN
237: FND_MESSAGE.Set_Name('CSF', 'CSFW_START_END_DATE_SAME');
238: p_error := -30;
239: p_error := FND_MESSAGE.Get;
240: RETURN;
241: END IF;

Line 239: p_error := FND_MESSAGE.Get;

235:
236: IF (p_labor_start_date >= p_labor_end_date) THEN
237: FND_MESSAGE.Set_Name('CSF', 'CSFW_START_END_DATE_SAME');
238: p_error := -30;
239: p_error := FND_MESSAGE.Get;
240: RETURN;
241: END IF;
242:
243: -- CALL THE VALIDATE FUNCTION

Line 707: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');

703: IF p_service_date between l_sr_date and sysdate
704: THEN
705: null;
706: ELSE
707: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
708: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(l_sr_date, l_dt_format));
709: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(sysdate, l_dt_format));
710: p_error := -21;
711: p_error := FND_MESSAGE.Get;

Line 708: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(l_sr_date, l_dt_format));

704: THEN
705: null;
706: ELSE
707: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
708: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(l_sr_date, l_dt_format));
709: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(sysdate, l_dt_format));
710: p_error := -21;
711: p_error := FND_MESSAGE.Get;
712: return;

Line 709: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(sysdate, l_dt_format));

705: null;
706: ELSE
707: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
708: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(l_sr_date, l_dt_format));
709: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(sysdate, l_dt_format));
710: p_error := -21;
711: p_error := FND_MESSAGE.Get;
712: return;
713:

Line 711: p_error := FND_MESSAGE.Get;

707: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
708: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(l_sr_date, l_dt_format));
709: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(sysdate, l_dt_format));
710: p_error := -21;
711: p_error := FND_MESSAGE.Get;
712: return;
713:
714: END IF;
715: */

Line 717: FND_MESSAGE.Set_Name('CSF', 'CSFW_START_END_DATE_SAME');

713:
714: END IF;
715: */
716: IF (p_labor_start_date >= p_labor_end_date) THEN
717: FND_MESSAGE.Set_Name('CSF', 'CSFW_START_END_DATE_SAME');
718: p_error := -30;
719: p_error := FND_MESSAGE.Get;
720: RETURN;
721: END IF;

Line 719: p_error := FND_MESSAGE.Get;

715: */
716: IF (p_labor_start_date >= p_labor_end_date) THEN
717: FND_MESSAGE.Set_Name('CSF', 'CSFW_START_END_DATE_SAME');
718: p_error := -30;
719: p_error := FND_MESSAGE.Get;
720: RETURN;
721: END IF;
722:
723: -- CALL THE VALIDATE FUNCTION

Line 1328: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');

1324:
1325: /* check in JSP only
1326: IF lp_servicedate not between l_sr_date and sysdate
1327: THEN
1328: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
1329: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
1330: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
1331:
1332:

Line 1329: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));

1325: /* check in JSP only
1326: IF lp_servicedate not between l_sr_date and sysdate
1327: THEN
1328: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
1329: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
1330: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
1331:
1332:
1333: p_error := -21;

Line 1330: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));

1326: IF lp_servicedate not between l_sr_date and sysdate
1327: THEN
1328: FND_MESSAGE.Set_Name('CSF', 'CSFW_SERVICE_DATE');
1329: FND_MESSAGE.Set_Token('P_SR_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(l_sr_date), l_dt_format||' HH24:MI'));
1330: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
1331:
1332:
1333: p_error := -21;
1334: p_error := FND_MESSAGE.Get;

Line 1334: p_error := FND_MESSAGE.Get;

1330: FND_MESSAGE.Set_Token('P_SYSTEM_DATE', to_char(CSFW_TIMEZONE_PUB.GET_CLIENT_TIME(sysdate), l_dt_format||' HH24:MI'));
1331:
1332:
1333: p_error := -21;
1334: p_error := FND_MESSAGE.Get;
1335: RETURN ;
1336: END IF;
1337:
1338: */