DBA Data[Home] [Help]

APPS.AHL_UMP_SR_PVT dependencies on AHL_UNIT_EFFECTIVITIES_PKG

Line 432: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY , ' BEFORE Calling TABLE HANDLER AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row' );

428: END IF;
429: END IF;
430:
431: IF (FND_LOG.LEVEL_PROCEDURE >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
432: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY , ' BEFORE Calling TABLE HANDLER AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row' );
433: END IF;
434:
435:
436: --******************************

Line 439: AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row (

435:
436: --******************************
437: -- Call Table Handler.
438: --******************************
439: AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row (
440: X_ROWID => l_rowid,
441: X_UNIT_EFFECTIVITY_ID => l_unit_effectivity_id,
442: X_MANUALLY_PLANNED_FLAG => 'Y',
443: X_LOG_SERIES_CODE => null,

Line 504: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY , ' AFTER Calling TABLE HANDLER AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row' );

500: X_LAST_UPDATED_BY => fnd_global.user_id,
501: X_LAST_UPDATE_LOGIN => fnd_global.login_id );
502:
503: IF (FND_LOG.LEVEL_PROCEDURE >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
504: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY , ' AFTER Calling TABLE HANDLER AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row' );
505: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY , ' Unit Effectivity ID:' || l_unit_effectivity_id);
506: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY , ' Return Status:' || x_return_status);
507: END IF;
508:

Line 1367: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => l_rel_dtls_rec.RELATED_UE_ID);

1363:
1364: IF (FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
1365: FND_LOG.STRING(FND_LOG.LEVEL_STATEMENT, L_DEBUG_KEY, 'About to Delete Unit Effectivity with UNIT_EFFECTIVITY_ID = ' || l_rel_dtls_rec.RELATED_UE_ID || ' for a Group MR');
1366: END IF;
1367: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => l_rel_dtls_rec.RELATED_UE_ID);
1368: END LOOP;
1369: -- Delete the MR Relationship and UE
1370: IF (FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
1371: FND_LOG.STRING(FND_LOG.LEVEL_STATEMENT, L_DEBUG_KEY, 'About to Delete Relationship with RELATIONSHIP_ID = ' || l_relationship_id);

Line 1378: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => p_sr_mr_association_tbl(i).UNIT_EFFECTIVITY_ID);

1374:
1375: IF (FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
1376: FND_LOG.STRING(FND_LOG.LEVEL_STATEMENT, L_DEBUG_KEY, 'About to Delete Unit Effectivity with UNIT_EFFECTIVITY_ID = ' || p_sr_mr_association_tbl(i).UNIT_EFFECTIVITY_ID);
1377: END IF;
1378: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => p_sr_mr_association_tbl(i).UNIT_EFFECTIVITY_ID);
1379:
1380: END IF; -- Disassociation Record
1381: END LOOP; -- All Association/Disassociation Records
1382:

Line 1739: AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row (

1735: IF (FND_LOG.LEVEL_PROCEDURE >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
1736: FND_LOG.STRING(FND_LOG.LEVEL_PROCEDURE, L_DEBUG_KEY || '.begin', 'Entering Procedure');
1737: END IF;
1738:
1739: AHL_UNIT_EFFECTIVITIES_PKG.Insert_Row (
1740: X_ROWID => l_temp_row_id,
1741: X_UNIT_EFFECTIVITY_ID => x_ue_id,
1742: X_MANUALLY_PLANNED_FLAG => 'Y',
1743: X_LOG_SERIES_CODE => null,

Line 2140: AHL_UNIT_EFFECTIVITIES_PKG.UPDATE_ROW(

2136: ELSE
2137: l_temp_tolerance_flag := l_curr_ue_rec.TOLERANCE_FLAG;
2138: END IF;
2139: -- Update the unit effectivity
2140: AHL_UNIT_EFFECTIVITIES_PKG.UPDATE_ROW(
2141: X_UNIT_EFFECTIVITY_ID => l_curr_ue_rec.UNIT_EFFECTIVITY_ID,
2142: X_MANUALLY_PLANNED_FLAG => l_curr_ue_rec.MANUALLY_PLANNED_FLAG,
2143: X_LOG_SERIES_CODE => l_curr_ue_rec.LOG_SERIES_CODE,
2144: X_LOG_SERIES_NUMBER => l_curr_ue_rec.LOG_SERIES_NUMBER,

Line 2320: AHL_UNIT_EFFECTIVITIES_PKG.UPDATE_ROW(

2316: l_temp_tolerance_flag := l_curr_ue_rec.TOLERANCE_FLAG;
2317: END IF;
2318:
2319: -- Update the unit effectivity
2320: AHL_UNIT_EFFECTIVITIES_PKG.UPDATE_ROW(
2321: X_UNIT_EFFECTIVITY_ID => l_curr_ue_rec.UNIT_EFFECTIVITY_ID,
2322: X_MANUALLY_PLANNED_FLAG => l_curr_ue_rec.MANUALLY_PLANNED_FLAG,
2323: X_LOG_SERIES_CODE => l_curr_ue_rec.LOG_SERIES_CODE,
2324: X_LOG_SERIES_NUMBER => l_curr_ue_rec.LOG_SERIES_NUMBER,

Line 2542: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => rel_and_ue_id_rec.RELATED_UE_ID);

2538: IF (FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
2539: FND_LOG.STRING(FND_LOG.LEVEL_STATEMENT, L_DEBUG_KEY, 'Deleted Relationship with UE_RELATIONSHIP_ID = ' || rel_and_ue_id_rec.UE_RELATIONSHIP_ID);
2540: END IF;
2541: -- Next delete the unit effectivity
2542: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => rel_and_ue_id_rec.RELATED_UE_ID);
2543: IF (FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
2544: FND_LOG.STRING(FND_LOG.LEVEL_STATEMENT, L_DEBUG_KEY, 'Deleted Unit Effectivity with UNIT_EFFECTIVITY_ID = ' || rel_and_ue_id_rec.RELATED_UE_ID);
2545: END IF;
2546: END LOOP;

Line 2549: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => p_sr_ue_id);

2545: END IF;
2546: END LOOP;
2547:
2548: -- Delete the SR's Unit Effectivity
2549: AHL_UNIT_EFFECTIVITIES_PKG.DELETE_ROW(X_UNIT_EFFECTIVITY_ID => p_sr_ue_id);
2550: IF (FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
2551: FND_LOG.STRING(FND_LOG.LEVEL_STATEMENT, L_DEBUG_KEY, 'Deleted Unit Effectivity with UNIT_EFFECTIVITY_ID = ' || p_sr_ue_id);
2552: END IF;
2553: END IF; -- Planned or Not