DBA Data[Home] [Help]

APPS.BIS_PMF_GET_DIMLEVELS_PVT dependencies on BIS_UTILITIES_PVT

Line 706: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_source => p_source);

702: END;
703: l_valuename := 'NAME';
704: END IF;
705: IF p_source IS NOT NULL THEN -- 2617369
706: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_source => p_source);
707: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>l_dimshortname
708: ,p_source => p_source
709: );
710: ELSE

Line 707: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>l_dimshortname

703: l_valuename := 'NAME';
704: END IF;
705: IF p_source IS NOT NULL THEN -- 2617369
706: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_source => p_source);
707: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>l_dimshortname
708: ,p_source => p_source
709: );
710: ELSE
711: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL

Line 711: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL

707: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>l_dimshortname
708: ,p_source => p_source
709: );
710: ELSE
711: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL
712: ,p_DimLevelName =>l_lvlshortname
713: );
714: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME(p_dim_short_name=>l_dimshortname
715: ,p_DimLevelId => NULL

Line 714: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME(p_dim_short_name=>l_dimshortname

710: ELSE
711: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL
712: ,p_DimLevelName =>l_lvlshortname
713: );
714: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME(p_dim_short_name=>l_dimshortname
715: ,p_DimLevelId => NULL
716: ,p_DimLevelName => l_lvlshortname
717: );
718: END IF;

Line 903: l_Is_Rolling_Period_Level := BIS_UTILITIES_PVT.Is_Rolling_Period_Level( -- 2408906

899: FND_MSG_PUB.ADD;
900: RAISE FND_API.G_EXC_ERROR;
901: END IF;
902: CLOSE c_dimlvls;
903: l_Is_Rolling_Period_Level := BIS_UTILITIES_PVT.Is_Rolling_Period_Level( -- 2408906
904: p_level_short_name => l_lvlshortname);
905:
906: IF ( l_Is_Rolling_Period_Level = 1 ) THEN -- 2408906
907:

Line 910: || BIS_UTILITIES_PVT.GET_FND_MESSAGE( 'BIS_ALL_VALUE_ROLLING' )

906: IF ( l_Is_Rolling_Period_Level = 1 ) THEN -- 2408906
907:
908: x_bis_select_string := ' select -1 Id, '
909: || ''''
910: || BIS_UTILITIES_PVT.GET_FND_MESSAGE( 'BIS_ALL_VALUE_ROLLING' )
911: || ''''
912: || ' Value, sysdate start_date, sysdate end_date from dual ' ;
913: -- ' select -1 Id, ' || '''All''' || ' Value from dual ' ;
914: -- ' select id, value, start_date, end_date from BIS_ROLLING_LEVEL_002 ' ;

Line 926: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_Source => p_source);

922:
923: ELSE
924:
925: IF p_source IS NOT NULL THEN -- 2617369
926: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_Source => p_source);
927: ELSE
928: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL
929: , p_DimLevelName => l_lvlshortname);
930: END IF;

Line 928: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL

924:
925: IF p_source IS NOT NULL THEN -- 2617369
926: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_Source => p_source);
927: ELSE
928: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL
929: , p_DimLevelName => l_lvlshortname);
930: END IF;
931:
932: -- Added condition to check if it is a Periodicity time Dimension Object

Line 1886: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_source => p_source);

1882: l_dimshortname_time bis_dimensions.short_name%TYPE;
1883: l_lvlshortname_total bis_levels.short_name%TYPE;
1884: BEGIN
1885: IF p_source IS NOT NULL THEN
1886: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_source => p_source);
1887:
1888: IF ((p_source = 'EDW') AND (p_data_source IS NULL)) THEN
1889: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>p_dimshortname
1890: ,p_source => p_source

Line 1889: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>p_dimshortname

1885: IF p_source IS NOT NULL THEN
1886: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME_SRC(p_source => p_source);
1887:
1888: IF ((p_source = 'EDW') AND (p_data_source IS NULL)) THEN
1889: l_lvlshortname_total := BIS_UTILITIES_PVT.GET_TOTAL_DIMLEVEL_NAME_SRC(p_dim_short_name=>p_dimshortname
1890: ,p_source => p_source
1891: );
1892: END IF;
1893: ELSE -- if source is null, it is oltp case

Line 1894: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL

1890: ,p_source => p_source
1891: );
1892: END IF;
1893: ELSE -- if source is null, it is oltp case
1894: l_dimshortname_time := BIS_UTILITIES_PVT.GET_TIME_DIMENSION_NAME(p_DimLevelId => NULL
1895: ,p_DimLevelName =>p_lvlshortname
1896: );
1897: END IF;
1898: