DBA Data[Home] [Help]

APPS.OTA_CCI_BUS dependencies on FND_MESSAGE

Line 74: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');

70: close csr_sec_grp;
71: --
72: -- The primary key is invalid therefore we must error
73: --
74: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');
75: hr_multi_message.add
76: (p_associated_column1
77: => nvl(p_associated_column1,'CATEGORY_USAGE_ID')
78: ,p_associated_column2

Line 168: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');

164: --
165: -- The primary key is invalid therefore we must error
166: --
167: close csr_leg_code;
168: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');
169: fnd_message.raise_error;
170: end if;
171: hr_utility.set_location(l_proc,30);
172: --

Line 169: fnd_message.raise_error;

165: -- The primary key is invalid therefore we must error
166: --
167: close csr_leg_code;
168: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');
169: fnd_message.raise_error;
170: end if;
171: hr_utility.set_location(l_proc,30);
172: --
173: -- Set the global variables so the values are

Line 368: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');

364: (p_category_usage_id => p_rec.category_usage_id
365: ,p_certification_id => p_rec.certification_id
366: ,p_object_version_number => p_rec.object_version_number
367: ) THEN
368: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
369: fnd_message.set_token('PROCEDURE ', l_proc);
370: fnd_message.set_token('STEP ', '5');
371: fnd_message.raise_error;
372: END IF;

Line 369: fnd_message.set_token('PROCEDURE ', l_proc);

365: ,p_certification_id => p_rec.certification_id
366: ,p_object_version_number => p_rec.object_version_number
367: ) THEN
368: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
369: fnd_message.set_token('PROCEDURE ', l_proc);
370: fnd_message.set_token('STEP ', '5');
371: fnd_message.raise_error;
372: END IF;
373: --

Line 370: fnd_message.set_token('STEP ', '5');

366: ,p_object_version_number => p_rec.object_version_number
367: ) THEN
368: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
369: fnd_message.set_token('PROCEDURE ', l_proc);
370: fnd_message.set_token('STEP ', '5');
371: fnd_message.raise_error;
372: END IF;
373: --
374: -- EDIT_HERE: Add checks to ensure non-updateable args have

Line 371: fnd_message.raise_error;

367: ) THEN
368: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
369: fnd_message.set_token('PROCEDURE ', l_proc);
370: fnd_message.set_token('STEP ', '5');
371: fnd_message.raise_error;
372: END IF;
373: --
374: -- EDIT_HERE: Add checks to ensure non-updateable args have
375: -- not been updated.

Line 442: fnd_message.set_name ( 'OTA','OTA_443896_CRT_OUT_OF_CAT_DATE');

438: IF ( l_cat_start_date > l_cert_start_date
439: or l_cat_end_date < l_cert_end_date
440: ) THEN
441: --
442: fnd_message.set_name ( 'OTA','OTA_443896_CRT_OUT_OF_CAT_DATE');
443: fnd_message.raise_error;
444: --
445: End IF;
446: ELSE

Line 443: fnd_message.raise_error;

439: or l_cat_end_date < l_cert_end_date
440: ) THEN
441: --
442: fnd_message.set_name ( 'OTA','OTA_443896_CRT_OUT_OF_CAT_DATE');
443: fnd_message.raise_error;
444: --
445: End IF;
446: ELSE
447: CLOSE csr_cat_start_end_date;

Line 621: fnd_message.set_name('OTA', 'OTA_13676_DCI_DUPLICATE');

617: --
618: if sel_multiple_primary%found then
619: close sel_multiple_primary;
620:
621: fnd_message.set_name('OTA', 'OTA_13676_DCI_DUPLICATE');
622: fnd_message.raise_error;
623: end if;
624: close sel_multiple_primary;
625: --

Line 622: fnd_message.raise_error;

618: if sel_multiple_primary%found then
619: close sel_multiple_primary;
620:
621: fnd_message.set_name('OTA', 'OTA_13676_DCI_DUPLICATE');
622: fnd_message.raise_error;
623: end if;
624: close sel_multiple_primary;
625: --
626: hr_utility.set_location(' Leaving:'|| v_proc, 10);

Line 675: fnd_message.set_name('OTA', 'OTA_443266_DCI_DEL_PRIMARY');

671: --
672: if sel_primary_category%found then
673: close sel_primary_category;
674:
675: fnd_message.set_name('OTA', 'OTA_443266_DCI_DEL_PRIMARY');
676: fnd_message.raise_error;
677: end if;
678: close sel_primary_category;
679: --

Line 676: fnd_message.raise_error;

672: if sel_primary_category%found then
673: close sel_primary_category;
674:
675: fnd_message.set_name('OTA', 'OTA_443266_DCI_DEL_PRIMARY');
676: fnd_message.raise_error;
677: end if;
678: close sel_primary_category;
679: --
680: hr_utility.set_location(' Leaving:'|| v_proc, 10);

Line 772: fnd_message.set_name('OTA', 'OTA_13676_DCI_DUPLICATE');

768: --
769: if sel_unique_key%found then
770: close sel_unique_key;
771:
772: fnd_message.set_name('OTA', 'OTA_13676_DCI_DUPLICATE');
773: fnd_message.raise_error;
774: end if;
775: close sel_unique_key;
776: --

Line 773: fnd_message.raise_error;

769: if sel_unique_key%found then
770: close sel_unique_key;
771:
772: fnd_message.set_name('OTA', 'OTA_13676_DCI_DUPLICATE');
773: fnd_message.raise_error;
774: end if;
775: close sel_unique_key;
776: --
777: hr_utility.set_location(' Leaving:'|| v_proc, 10);