DBA Data[Home] [Help]

APPS.PA_REPORT_UTIL dependencies on PA_UTILS

Line 83: PA_UTILS.Add_Message( p_app_short_name =>'PA',

79: from pa_implementations;
80: EXCEPTION
81: WHEN NO_DATA_FOUND THEN
82: x_return_status := FND_API.G_RET_STS_ERROR;
83: PA_UTILS.Add_Message( p_app_short_name =>'PA',
84: p_msg_name => 'PA_INCORRECT_MO_OPERATING_UNIT');
85:
86: l_msg_count := FND_MSG_PUB.count_msg;
87: IF l_msg_count > 0 then

Line 125: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_ORG_NAME');

121: the organization authorities on any organizations for the current Operatin Unit.
122: Note that no need to "return" here after populating the message, as further other
123: profile options are being checked that whether they have been populated or not*/
124:
125: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_ORG_NAME');
126: x_return_status := FND_API.G_RET_STS_ERROR;
127: x_msg_data := 'PA_UTIL_INVALID_ORG_NAME';
128: x_msg_count := 1;
129: IF x_msg_count = 1 THEN

Line 208: PA_UTILS.Add_Message( p_app_short_name =>'PA',

204: END IF;
205: END IF;
206:
207: IF x_return_status = FND_API.G_RET_STS_ERROR and l_err_msg is not null THEN
208: PA_UTILS.Add_Message( p_app_short_name =>'PA',
209: p_msg_name => 'PA_UNDEFINED_PROFILES',
210: p_token1 => 'PROFILES',
211: p_value1 => l_err_msg);
212:

Line 261: PA_UTILS.Add_Message( p_app_short_name =>'PA',

257: /* Bug2440313 Begin -- Undone the check for MO: Operating Unit here. The Operating Unit check
258: is now done above in this code. Here we do check for utilization options defined or not */
259:
260: x_return_status := FND_API.G_RET_STS_ERROR;
261: PA_UTILS.Add_Message( p_app_short_name =>'PA',
262: p_msg_name => 'PA_UNDEFINED_UTIL_OPTIONS');
263:
264: l_msg_count := FND_MSG_PUB.count_msg;
265: IF l_msg_count > 0 then

Line 341: PA_UTILS.Add_Message( p_app_short_name =>'PA',

337: /*NPE changes Begins */
338: EXCEPTION
339: WHEN NO_DATA_FOUND THEN
340: x_return_status := FND_API.G_RET_STS_ERROR;
341: PA_UTILS.Add_Message( p_app_short_name =>'PA',
342: p_msg_name => 'PA_PRD_NOT_DEFINED_FOR_DATE',
343: p_token1 => 'PA_DATE',
344: p_value1 => to_char(l_default_date,l_date_format));
345: l_msg_count := FND_MSG_PUB.count_msg;

Line 402: PA_UTILS.Add_Message( p_app_short_name =>'PA',

398: /*NPE changes starts */
399: EXCEPTION
400: WHEN NO_DATA_FOUND THEN
401: x_return_status := FND_API.G_RET_STS_ERROR;
402: PA_UTILS.Add_Message( p_app_short_name =>'PA',
403: p_msg_name => 'PA_GL_PRD_NOT_DEFINED_FOR_DATE',
404: p_token1 => 'GL_DATE',
405: p_value1 => to_char(l_default_date,l_date_format));
406: l_msg_count := FND_MSG_PUB.count_msg;

Line 431: PA_UTILS.Add_Message( p_app_short_name =>'PA',

427: ELSIF ( l_period_type = 'GE') THEN
428: /* NPE Changes Begins */
429: IF l_global_week_start_day IS NULL THEN
430: x_return_status := FND_API.G_RET_STS_ERROR;
431: PA_UTILS.Add_Message( p_app_short_name =>'PA',
432: p_msg_name => 'PA_UNDEFINED_PROFILES',
433: p_token1 => 'PROFILES',
434: p_value1 => l_user_profile_option_name3);
435:

Line 570: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_ORG_NAME');

566: END IF;
567:
568: EXCEPTION
569: WHEN NO_DATA_FOUND THEN
570: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_ORG_NAME');
571: x_return_status := FND_API.G_RET_STS_ERROR;
572: x_msg_data := 'PA_UTIL_INVALID_ORG_NAME';
573: x_msg_count := 1;
574: IF x_msg_count = 1 THEN

Line 596: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_TYPE');

592: x_period_type := l_period_type;
593:
594: EXCEPTION
595: WHEN NO_DATA_FOUND THEN
596: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_TYPE');
597: x_return_status := FND_API.G_RET_STS_ERROR;
598: x_msg_data := 'PA_UTIL_INVALID_PRD_TYPE';
599: x_msg_count := 1;
600: IF x_msg_count = 1 THEN

Line 621: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');

617: AND period_year = p_select_yr
618: AND ROWNUM = 1;
619: EXCEPTION
620: WHEN NO_DATA_FOUND THEN
621: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');
622: x_return_status := FND_API.G_RET_STS_ERROR;
623: x_msg_data := 'PA_UTIL_INVALID_PRD_YEAR';
624: x_msg_count := 1;
625: IF x_msg_count = 1 THEN

Line 645: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');

641: AND period_year = p_select_yr
642: AND ROWNUM = 1;
643: EXCEPTION
644: WHEN NO_DATA_FOUND THEN
645: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');
646: x_return_status := FND_API.G_RET_STS_ERROR;
647: x_msg_data := 'PA_UTIL_INVALID_PRD_YEAR';
648: x_msg_count := 1;
649: IF x_msg_count = 1 THEN

Line 682: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_NAME');

678: AND period_year = p_select_yr;
679: END IF;
680: EXCEPTION
681: WHEN NO_DATA_FOUND THEN
682: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_NAME');
683: x_return_status := FND_API.G_RET_STS_ERROR;
684: x_msg_data := 'PA_UTIL_INVALID_PRD_NAME';
685: x_msg_count := 1;
686: IF x_msg_count = 1 THEN

Line 800: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_TYPE');

796: WHERE period_type_desc = p_period_type_desc;
797:
798: EXCEPTION
799: WHEN NO_DATA_FOUND THEN
800: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_TYPE');
801: x_return_status := FND_API.G_RET_STS_ERROR;
802: x_msg_data := 'PA_UTIL_INVALID_PRD_TYPE';
803: x_msg_count := 1;
804: IF x_msg_count = 1 THEN

Line 830: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');

826: AND ROWNUM =1;
827:
828: EXCEPTION
829: WHEN NO_DATA_FOUND THEN
830: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');
831: x_return_status := FND_API.G_RET_STS_ERROR;
832: x_msg_data := 'PA_UTIL_INVALID_PRD_YEAR';
833: x_msg_count := 1;
834: IF x_msg_count = 1 THEN

Line 855: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');

851: AND ROWNUM =1;
852:
853: EXCEPTION
854: WHEN NO_DATA_FOUND THEN
855: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_YEAR');
856: x_return_status := FND_API.G_RET_STS_ERROR;
857: x_msg_data := 'PA_UTIL_INVALID_PRD_YEAR';
858: x_msg_count := 1;
859: IF x_msg_count = 1 THEN

Line 883: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_NAME');

879: AND period_year = p_period_year;
880:
881: EXCEPTION
882: WHEN NO_DATA_FOUND THEN
883: PA_UTILS.Add_Message( 'PA', 'PA_UTIL_INVALID_PRD_NAME');
884: x_return_status := FND_API.G_RET_STS_ERROR;
885: x_msg_data := 'PA_UTIL_INVALID_PRD_NAME';
886: x_msg_count := 1;
887: IF x_msg_count = 1 THEN

Line 1094: PA_UTILS.Add_Message( p_app_short_name =>'PA',

1090: from pa_implementations;
1091: EXCEPTION
1092: WHEN NO_DATA_FOUND THEN
1093: x_return_status := FND_API.G_RET_STS_ERROR;
1094: PA_UTILS.Add_Message( p_app_short_name =>'PA',
1095: p_msg_name => 'PA_INCORRECT_MO_OPERATING_UNIT');
1096:
1097: l_msg_count := FND_MSG_PUB.count_msg;
1098: IF l_msg_count > 0 then

Line 1159: PA_UTILS.Add_Message( p_app_short_name =>'PA',

1155: END IF;
1156: END IF;
1157:
1158: IF x_return_status = FND_API.G_RET_STS_ERROR and l_err_msg is not null THEN
1159: PA_UTILS.Add_Message( p_app_short_name =>'PA',
1160: p_msg_name => 'PA_UNDEFINED_PROFILES',
1161: p_token1 => 'PROFILES',
1162: p_value1 => l_err_msg);
1163:

Line 1216: PA_UTILS.Add_Message( p_app_short_name =>'PA',

1212: /* Bug2440313 Begin -- Undone the check for MO: Operating Unit here. The Operating Unit check
1213: is now done above in this code. Here we do check for utilization options defined or not */
1214:
1215: x_return_status := FND_API.G_RET_STS_ERROR;
1216: PA_UTILS.Add_Message( p_app_short_name =>'PA',
1217: p_msg_name => 'PA_UNDEFINED_UTIL_OPTIONS');
1218:
1219: l_msg_count := FND_MSG_PUB.count_msg;
1220: IF l_msg_count > 0 then

Line 1295: PA_UTILS.Add_Message( p_app_short_name =>'PA',

1291: /*NPE changes Begins */
1292: EXCEPTION
1293: WHEN NO_DATA_FOUND THEN
1294: x_return_status := FND_API.G_RET_STS_ERROR;
1295: PA_UTILS.Add_Message( p_app_short_name =>'PA',
1296: p_msg_name => 'PA_PRD_NOT_DEFINED_FOR_DATE',
1297: p_token1 => 'PA_DATE',
1298: p_value1 => to_char(l_default_date,l_date_format));
1299: l_msg_count := FND_MSG_PUB.count_msg;

Line 1362: PA_UTILS.Add_Message( p_app_short_name =>'PA',

1358: /*NPE changes starts */
1359: EXCEPTION
1360: WHEN NO_DATA_FOUND THEN
1361: x_return_status := FND_API.G_RET_STS_ERROR;
1362: PA_UTILS.Add_Message( p_app_short_name =>'PA',
1363: p_msg_name => 'PA_GL_PRD_NOT_DEFINED_FOR_DATE',
1364: p_token1 => 'GL_DATE',
1365: p_value1 => to_char(l_default_date,l_date_format));
1366: l_msg_count := FND_MSG_PUB.count_msg;

Line 1391: PA_UTILS.Add_Message( p_app_short_name =>'PA',

1387: ELSIF ( l_period_type = 'GE') THEN
1388: /* NPE Changes Begins */
1389: IF l_global_week_start_day IS NULL THEN
1390: x_return_status := FND_API.G_RET_STS_ERROR;
1391: PA_UTILS.Add_Message( p_app_short_name =>'PA',
1392: p_msg_name => 'PA_UNDEFINED_PROFILES',
1393: p_token1 => 'PROFILES',
1394: p_value1 => l_user_profile_option_name3);
1395: