DBA Data[Home] [Help]

APPS.OTA_RUD_BUS dependencies on FND_MESSAGE

Line 65: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');

61: close csr_sec_grp;
62: --
63: -- The primary key is invalid therefore we must error
64: --
65: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');
66: hr_multi_message.add
67: (p_associated_column1
68: => nvl(p_associated_column1,'RESOURCE_USAGE_ID')
69: );

Line 148: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');

144: --
145: -- The primary key is invalid therefore we must error
146: --
147: close csr_leg_code;
148: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');
149: fnd_message.raise_error;
150: end if;
151: hr_utility.set_location(l_proc,30);
152: --

Line 149: fnd_message.raise_error;

145: -- The primary key is invalid therefore we must error
146: --
147: close csr_leg_code;
148: fnd_message.set_name('PAY','HR_7220_INVALID_PRIMARY_KEY');
149: fnd_message.raise_error;
150: end if;
151: hr_utility.set_location(l_proc,30);
152: --
153: -- Set the global variables so the values are

Line 493: fnd_message.set_name ( 'OTA', 'OTA_13265_TRB_QUANTITY_ENTERED');

489: If p_resource_type = 'V' or p_resource_type = 'T' Then
490: --
491: If p_quantity is null or p_quantity <> 1 Then
492: --
493: fnd_message.set_name ( 'OTA', 'OTA_13265_TRB_QUANTITY_ENTERED');
494: fnd_message.raise_error;
495: --
496: End If;
497: ElsIf p_quantity < 1 Then

Line 494: fnd_message.raise_error;

490: --
491: If p_quantity is null or p_quantity <> 1 Then
492: --
493: fnd_message.set_name ( 'OTA', 'OTA_13265_TRB_QUANTITY_ENTERED');
494: fnd_message.raise_error;
495: --
496: End If;
497: ElsIf p_quantity < 1 Then
498: --

Line 499: fnd_message.set_name ( 'OTA', 'OTA_443369_POSITIVE_WHL_NUMBER');

495: --
496: End If;
497: ElsIf p_quantity < 1 Then
498: --
499: fnd_message.set_name ( 'OTA', 'OTA_443369_POSITIVE_WHL_NUMBER');
500: fnd_message.raise_error;
501: --
502: End If;
503: --

Line 500: fnd_message.raise_error;

496: End If;
497: ElsIf p_quantity < 1 Then
498: --
499: fnd_message.set_name ( 'OTA', 'OTA_443369_POSITIVE_WHL_NUMBER');
500: fnd_message.raise_error;
501: --
502: End If;
503: --
504: hr_utility.set_location ('Leaving:' || l_proc, 20);

Line 807: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');

803: IF NOT ota_rud_shd.api_updating
804: (p_resource_usage_id => p_rec.resource_usage_id
805: ,p_object_version_number => p_rec.object_version_number
806: ) THEN
807: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
808: fnd_message.set_token('PROCEDURE ', l_proc);
809: fnd_message.set_token('STEP ', '5');
810: fnd_message.raise_error;
811: END IF;

Line 808: fnd_message.set_token('PROCEDURE ', l_proc);

804: (p_resource_usage_id => p_rec.resource_usage_id
805: ,p_object_version_number => p_rec.object_version_number
806: ) THEN
807: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
808: fnd_message.set_token('PROCEDURE ', l_proc);
809: fnd_message.set_token('STEP ', '5');
810: fnd_message.raise_error;
811: END IF;
812: --

Line 809: fnd_message.set_token('STEP ', '5');

805: ,p_object_version_number => p_rec.object_version_number
806: ) THEN
807: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
808: fnd_message.set_token('PROCEDURE ', l_proc);
809: fnd_message.set_token('STEP ', '5');
810: fnd_message.raise_error;
811: END IF;
812: --
813: -- EDIT_HERE: Add checks to ensure non-updateable args have

Line 810: fnd_message.raise_error;

806: ) THEN
807: fnd_message.set_name('PER', 'HR_6153_ALL_PROCEDURE_FAIL');
808: fnd_message.set_token('PROCEDURE ', l_proc);
809: fnd_message.set_token('STEP ', '5');
810: fnd_message.raise_error;
811: END IF;
812: --
813: -- EDIT_HERE: Add checks to ensure non-updateable args have
814: -- not been updated.