DBA Data[Home] [Help]

APPS.BSC_DIMENSION_SETS_PUB dependencies on FND_MESSAGE

Line 156: FND_MESSAGE.SET_NAME('BSC','BSC_KPI_COMMON_DIM_OBJS');

152: AND KPI_GROUP.Indicator = l_Dim_Set_Rec.Bsc_Kpi_Id
153: AND KPI_GROUP.Dim_Set_Id = l_Dim_Set_Rec.Bsc_Dim_Set_Id
154: GROUP BY SYS_DIM_LEL.Dim_Level_Id);
155: IF (l_count > 1) THEN
156: FND_MESSAGE.SET_NAME('BSC','BSC_KPI_COMMON_DIM_OBJS');
157: FND_MSG_PUB.ADD;
158: RAISE FND_API.G_EXC_ERROR;
159: END IF;
160: END IF;

Line 424: FND_MESSAGE.SET_NAME('BSC','BSC_KPI_COMMON_DIM_OBJS');

420: AND KPI_GROUP.Indicator = p_Dim_Set_Rec.Bsc_Kpi_Id
421: AND KPI_GROUP.Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
422: GROUP BY SYS_DIM_LEL.Dim_Level_Id);
423: IF (l_count > 1) THEN
424: FND_MESSAGE.SET_NAME('BSC','BSC_KPI_COMMON_DIM_OBJS');
425: FND_MSG_PUB.ADD;
426: RAISE FND_API.G_EXC_ERROR;
427: END IF;
428: IF (p_create_Dim_Lev_Grp) THEN

Line 1796: FND_MESSAGE.SET_NAME('BSC','BSC_DIM_SET_OVERFLOW');

1792: WHERE Indicator = p_Dim_Set_Rec.Bsc_Kpi_Id
1793: AND Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
1794: AND Level_Source = 'BSC';
1795: IF (l_count > BSC_UTILITY.MAX_DIM_IN_DIM_SET) THEN
1796: FND_MESSAGE.SET_NAME('BSC','BSC_DIM_SET_OVERFLOW');
1797: FND_MSG_PUB.ADD;
1798: RAISE FND_API.G_EXC_ERROR;
1799: END IF;
1800:

Line 1812: FND_MESSAGE.SET_NAME('BSC','BSC_NO_MIX_DIM_SET_SOURCE');

1808: WHERE Indicator = p_Dim_Set_Rec.Bsc_Kpi_Id
1809: AND Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
1810: AND Level_Source IS NOT NULL;
1811: IF (l_count > 1) THEN
1812: FND_MESSAGE.SET_NAME('BSC','BSC_NO_MIX_DIM_SET_SOURCE');
1813: FND_MSG_PUB.ADD;
1814: RAISE FND_API.G_EXC_ERROR;
1815: END IF;
1816: END IF;

Line 1826: FND_MESSAGE.SET_NAME('BSC','BSC_D_ONE_DIM_IN_COMPARISON');

1822: AND Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
1823: AND DEFAULT_VALUE = 'C'
1824: AND Level_Source = 'BSC';
1825: IF (l_count > 1) THEN -- not more that 1 DimObj can be in comparison within a Dimension Set.
1826: FND_MESSAGE.SET_NAME('BSC','BSC_D_ONE_DIM_IN_COMPARISON');
1827: FND_MSG_PUB.ADD;
1828: RAISE FND_API.G_EXC_ERROR;
1829: END IF;
1830: END IF;

Line 1973: FND_MESSAGE.SET_NAME('BSC','BSC_NO_MIX_DIM_SET_SOURCE');

1969: WHERE Indicator = p_Dim_Set_Rec.Bsc_Kpi_Id
1970: AND Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
1971: AND Level_Source IS NOT NULL;
1972: IF (l_count > 1) THEN
1973: FND_MESSAGE.SET_NAME('BSC','BSC_NO_MIX_DIM_SET_SOURCE');
1974: FND_MSG_PUB.ADD;
1975: RAISE FND_API.G_EXC_ERROR;
1976: END IF;
1977: END IF;

Line 1986: FND_MESSAGE.SET_NAME('BSC','BSC_DIM_SET_OVERFLOW');

1982: WHERE Indicator = p_Dim_Set_Rec.Bsc_Kpi_Id
1983: AND Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
1984: AND Level_Source = 'BSC';
1985: IF (l_count > BSC_UTILITY.MAX_DIM_IN_DIM_SET) THEN
1986: FND_MESSAGE.SET_NAME('BSC','BSC_DIM_SET_OVERFLOW');
1987: x_msg_data := x_msg_data || bsc_apps.get_message('BSC_DIM_SET_OVERFLOW');
1988: FND_MSG_PUB.ADD;
1989: RAISE FND_API.G_EXC_ERROR;
1990: END IF;

Line 1998: FND_MESSAGE.SET_NAME('BSC','BSC_ONE_DIM_OBJ_IN_COMPARISON'); -- Need to change to a better meaning,

1994: WHERE Indicator = p_Dim_Set_Rec.Bsc_Kpi_Id
1995: AND Dim_Set_Id = p_Dim_Set_Rec.Bsc_Dim_Set_Id
1996: AND DEFAULT_VALUE= 'C';
1997: IF (l_count > 1) THEN -- not more that 1 DimObj can be in comparison within a Dimension Set.
1998: FND_MESSAGE.SET_NAME('BSC','BSC_ONE_DIM_OBJ_IN_COMPARISON'); -- Need to change to a better meaning,
1999: x_msg_data := x_msg_data || bsc_apps.get_message('BSC_ONE_DIM_OBJ_IN_COMPARISON');
2000: FND_MSG_PUB.ADD;
2001: RAISE FND_API.G_EXC_ERROR;
2002: END IF;