DBA Data[Home] [Help]

APPS.PER_SLS_SHD dependencies on PER_SLS_SHD

Line 1: Package Body per_sls_shd as

1: Package Body per_sls_shd as
2: /* $Header: peslsrhi.pkb 115.2 2003/08/07 23:58:22 vkonda noship $ */
3: --
4: -- ----------------------------------------------------------------------------
5: -- | Private Global Definitions |

Line 8: g_package varchar2(33) := ' per_sls_shd.'; -- Global package name

4: -- ----------------------------------------------------------------------------
5: -- | Private Global Definitions |
6: -- ----------------------------------------------------------------------------
7: --
8: g_package varchar2(33) := ' per_sls_shd.'; -- Global package name
9: --
10: -- ----------------------------------------------------------------------------
11: -- |---------------------------< constraint_error >---------------------------|
12: -- ----------------------------------------------------------------------------

Line 75: = per_sls_shd.g_old_rec.solution_set_name and

71: --
72: l_fct_ret := false;
73: Else
74: If (p_solution_set_name
75: = per_sls_shd.g_old_rec.solution_set_name and
76: p_user_id
77: = per_sls_shd.g_old_rec.user_id and
78: p_object_version_number
79: = per_sls_shd.g_old_rec.object_version_number

Line 77: = per_sls_shd.g_old_rec.user_id and

73: Else
74: If (p_solution_set_name
75: = per_sls_shd.g_old_rec.solution_set_name and
76: p_user_id
77: = per_sls_shd.g_old_rec.user_id and
78: p_object_version_number
79: = per_sls_shd.g_old_rec.object_version_number
80: ) Then
81: --

Line 79: = per_sls_shd.g_old_rec.object_version_number

75: = per_sls_shd.g_old_rec.solution_set_name and
76: p_user_id
77: = per_sls_shd.g_old_rec.user_id and
78: p_object_version_number
79: = per_sls_shd.g_old_rec.object_version_number
80: ) Then
81: --
82: -- The g_old_rec is current therefore we must
83: -- set the returning function to true

Line 91: Fetch C_Sel1 Into per_sls_shd.g_old_rec;

87: --
88: -- Select the current row into g_old_rec
89: --
90: Open C_Sel1;
91: Fetch C_Sel1 Into per_sls_shd.g_old_rec;
92: If C_Sel1%notfound Then
93: Close C_Sel1;
94: --
95: -- The primary key is invalid therefore we must error

Line 102: <> per_sls_shd.g_old_rec.object_version_number) Then

98: fnd_message.raise_error;
99: End If;
100: Close C_Sel1;
101: If (p_object_version_number
102: <> per_sls_shd.g_old_rec.object_version_number) Then
103: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
104: fnd_message.raise_error;
105: End If;
106: l_fct_ret := true;

Line 161: Fetch C_Sel1 Into per_sls_shd.g_old_rec;

157: ,p_argument_value => p_object_version_number
158: );
159: --
160: Open C_Sel1;
161: Fetch C_Sel1 Into per_sls_shd.g_old_rec;
162: If C_Sel1%notfound then
163: Close C_Sel1;
164: --
165: -- The primary key is invalid therefore we must error

Line 172: <> per_sls_shd.g_old_rec.object_version_number) Then

168: fnd_message.raise_error;
169: End If;
170: Close C_Sel1;
171: If (p_object_version_number
172: <> per_sls_shd.g_old_rec.object_version_number) Then
173: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
174: fnd_message.raise_error;
175: End If;
176: --

Line 224: end per_sls_shd;

220: Return(l_rec);
221: --
222: End convert_args;
223: --
224: end per_sls_shd;