DBA Data[Home] [Help]

APPS.OTA_LPM_SHD dependencies on FND_MESSAGE

Line 22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');

18: --
19: Begin
20: --
21: If (p_constraint_name = 'OTA_LEARNING_PATH_MEMBERS_UK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else

Line 23: fnd_message.set_token('PROCEDURE', l_proc);

19: Begin
20: --
21: If (p_constraint_name = 'OTA_LEARNING_PATH_MEMBERS_UK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');

Line 24: fnd_message.set_token('STEP','5');

20: --
21: If (p_constraint_name = 'OTA_LEARNING_PATH_MEMBERS_UK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);

Line 25: fnd_message.raise_error;

21: If (p_constraint_name = 'OTA_LEARNING_PATH_MEMBERS_UK1') Then
22: fnd_message.set_name('PAY', 'HR_6153_ALL_PROCEDURE_FAIL');
23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);

Line 27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');

23: fnd_message.set_token('PROCEDURE', l_proc);
24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;

Line 28: fnd_message.set_token('PROCEDURE', l_proc);

24: fnd_message.set_token('STEP','5');
25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;
32: --

Line 29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);

25: fnd_message.raise_error;
26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;
32: --
33: End constraint_error;

Line 30: fnd_message.raise_error;

26: Else
27: fnd_message.set_name('PAY', 'HR_7877_API_INVALID_CONSTRAINT');
28: fnd_message.set_token('PROCEDURE', l_proc);
29: fnd_message.set_token('CONSTRAINT_NAME', p_constraint_name);
30: fnd_message.raise_error;
31: End If;
32: --
33: End constraint_error;
34: --

Line 117: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');

113: Close C_Sel1;
114: --
115: -- The primary key is invalid therefore we must error
116: --
117: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
118: fnd_message.raise_error;
119: End If;
120: Close C_Sel1;
121: If (p_object_version_number

Line 118: fnd_message.raise_error;

114: --
115: -- The primary key is invalid therefore we must error
116: --
117: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
118: fnd_message.raise_error;
119: End If;
120: Close C_Sel1;
121: If (p_object_version_number
122: <> ota_lpm_shd.g_old_rec.object_version_number) Then

Line 123: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');

119: End If;
120: Close C_Sel1;
121: If (p_object_version_number
122: <> ota_lpm_shd.g_old_rec.object_version_number) Then
123: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
124: fnd_message.raise_error;
125: End If;
126: l_fct_ret := true;
127: End If;

Line 124: fnd_message.raise_error;

120: Close C_Sel1;
121: If (p_object_version_number
122: <> ota_lpm_shd.g_old_rec.object_version_number) Then
123: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
124: fnd_message.raise_error;
125: End If;
126: l_fct_ret := true;
127: End If;
128: End If;

Line 204: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');

200: Close C_Sel1;
201: --
202: -- The primary key is invalid therefore we must error
203: --
204: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
205: fnd_message.raise_error;
206: End If;
207: Close C_Sel1;
208: If (p_object_version_number

Line 205: fnd_message.raise_error;

201: --
202: -- The primary key is invalid therefore we must error
203: --
204: fnd_message.set_name('PAY', 'HR_7220_INVALID_PRIMARY_KEY');
205: fnd_message.raise_error;
206: End If;
207: Close C_Sel1;
208: If (p_object_version_number
209: <> ota_lpm_shd.g_old_rec.object_version_number) Then

Line 210: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');

206: End If;
207: Close C_Sel1;
208: If (p_object_version_number
209: <> ota_lpm_shd.g_old_rec.object_version_number) Then
210: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
211: fnd_message.raise_error;
212: End If;
213: --
214: hr_utility.set_location(' Leaving:'||l_proc, 10);

Line 211: fnd_message.raise_error;

207: Close C_Sel1;
208: If (p_object_version_number
209: <> ota_lpm_shd.g_old_rec.object_version_number) Then
210: fnd_message.set_name('PAY', 'HR_7155_OBJECT_INVALID');
211: fnd_message.raise_error;
212: End If;
213: --
214: hr_utility.set_location(' Leaving:'||l_proc, 10);
215: --

Line 224: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');

220: --
221: -- The object is locked therefore we need to supply a meaningful
222: -- error message.
223: --
224: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');
225: fnd_message.set_token('TABLE_NAME', 'ota_learning_path_members');
226: fnd_message.raise_error;
227: End lck;
228: --

Line 225: fnd_message.set_token('TABLE_NAME', 'ota_learning_path_members');

221: -- The object is locked therefore we need to supply a meaningful
222: -- error message.
223: --
224: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');
225: fnd_message.set_token('TABLE_NAME', 'ota_learning_path_members');
226: fnd_message.raise_error;
227: End lck;
228: --
229: -- ----------------------------------------------------------------------------

Line 226: fnd_message.raise_error;

222: -- error message.
223: --
224: fnd_message.set_name('PAY', 'HR_7165_OBJECT_LOCKED');
225: fnd_message.set_token('TABLE_NAME', 'ota_learning_path_members');
226: fnd_message.raise_error;
227: End lck;
228: --
229: -- ----------------------------------------------------------------------------
230: -- |-----------------------------< convert_args >-----------------------------|