[Home] [Help]
[Dependency Information]
| Object Name: | MSC_BOM_COMPONENTS |
|---|---|
| Object Type: | TABLE |
| Owner: | MSC |
| FND Design Data: | MSC.MSC_BOM_COMPONENTS
|
| Subobject Name: | |
| Status: | VALID |
This table stores the components used in a bill of material created at source applications.
This table is also used to store bill of material information for production sequencing on the supply chain hub.
| Tablespace: | ![]() |
|---|---|
| PCT Free: | |
| PCT Used: |
| Index | Type | Uniqueness | Tablespace | Column |
|---|---|---|---|---|
| MSC_BOM_COMPONENTS_U1 | NORMAL | UNIQUE |
|
PLAN_ID
SR_INSTANCE_ID
BILL_SEQUENCE_ID
COMPONENT_SEQUENCE_ID
|
| MSC_BOM_COMPONENTS_N3 | NORMAL | NONUNIQUE |
|
PLAN_ID
BILL_SEQUENCE_ID
INVENTORY_ITEM_ID
FROM_UNIT_NUMBER
SR_INSTANCE_ID
|
| MSC_BOM_COMPONENTS_N4 | NORMAL | NONUNIQUE |
|
PLAN_ID
BILL_SEQUENCE_ID
SR_INSTANCE_ID
INVENTORY_ITEM_ID
EFFECTIVITY_DATE
FROM_UNIT_NUMBER
|
| MSC_BOM_COMPONENTS_N5 | NORMAL | NONUNIQUE |
|
PLAN_ID
SR_INSTANCE_ID
INVENTORY_ITEM_ID
ORGANIZATION_ID
|
| Name | Datatype | Length | Mandatory | Comments |
|---|---|---|---|---|
| PLAN_ID | NUMBER | Yes | Plan identifier | |
| COMPONENT_SEQUENCE_ID | NUMBER | Yes | Component identifier on the source application instance | |
| BILL_SEQUENCE_ID | NUMBER | Yes | Identifier of the BOM | |
| SR_INSTANCE_ID | NUMBER | Yes | Source application instance identifier | |
| ORGANIZATION_ID | NUMBER | Yes | Organization identifier | |
| INVENTORY_ITEM_ID | NUMBER | Yes | Identifier of the component item | |
| USING_ASSEMBLY_ID | NUMBER | Identifier of the item being assembled | ||
| COMPONENT_TYPE | NUMBER | Component (1), Ingredient component (-1), by-product (2) | ||
| SCALING_TYPE | NUMBER | Scaling type | ||
| CHANGE_NOTICE | VARCHAR2 | (10) | Code for ECO. Use for UI and reporting | |
| REVISION | VARCHAR2 | (3) | Inventory item revision code | |
| UOM_CODE | VARCHAR2 | (3) | Unit of measure code | |
| USAGE_QUANTITY | NUMBER | Quantity of the component to build one unit of item | ||
| EFFECTIVITY_DATE | DATE | Date of effectivity for this component | ||
| DISABLE_DATE | DATE | End of effectivity | ||
| FROM_UNIT_NUMBER | VARCHAR2 | (30) | Effective from this unit number | |
| TO_UNIT_NUMBER | VARCHAR2 | (30) | Effective up to this unit number | |
| USE_UP_CODE | NUMBER | Yes/No flag - if yes this component is effective until the available quantity becomes null | ||
| SUGGESTED_EFFECTIVITY_DATE | DATE | Calculated use-up-date (if Use-up-code is yes) | ||
| DRIVING_ITEM_ID | NUMBER | Item which consumption determine the switch to this component | ||
| OPERATION_OFFSET_PERCENT | NUMBER | Operation offset percent | ||
| OPTIONAL_COMPONENT | NUMBER | Yes/No flag if optional use planning factor to determine demand | ||
| OLD_EFFECTIVITY_DATE | DATE | Old effectivity date | ||
| WIP_SUPPLY_TYPE | NUMBER | Used mainly for phantoms | ||
| PLANNING_FACTOR | NUMBER | Planning factor for this component (percent) | ||
| ATP_FLAG | NUMBER | Yes/No flag used for ATP | ||
| COMPONENT_YIELD_FACTOR | NUMBER | Yes | Factor used to multiply component quantity with to obtain component quantity | |
| REFRESH_NUMBER | NUMBER | Refresh number populated by the collection program | ||
| LAST_UPDATE_DATE | DATE | Yes | Standard Who column | |
| LAST_UPDATED_BY | NUMBER | Yes | Standard Who column | |
| CREATION_DATE | DATE | Yes | Standard Who column | |
| CREATED_BY | NUMBER | Yes | Standard Who column | |
| LAST_UPDATE_LOGIN | NUMBER | Standard Who column | ||
| REQUEST_ID | NUMBER | Concurrent Who column | ||
| PROGRAM_APPLICATION_ID | NUMBER | Concurrent Who column | ||
| PROGRAM_ID | NUMBER | Concurrent Who column | ||
| PROGRAM_UPDATE_DATE | DATE | Concurrent Who column | ||
| ATTRIBUTE_CATEGORY | VARCHAR2 | (30) | Descriptive Flexfield structure defining column | |
| ATTRIBUTE1 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE2 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE3 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE4 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE5 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE6 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE7 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE8 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE9 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE10 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE11 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE12 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE13 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE14 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| ATTRIBUTE15 | VARCHAR2 | (150) | Descriptive Flexfield segment | |
| SCALE_MULTIPLE | NUMBER | Scale Multiple | ||
| SCALE_ROUNDING_VARIANCE | NUMBER | Scale Rounding Variance | ||
| ROUNDING_DIRECTION | NUMBER | Rounding Direction | ||
| PRIMARY_FLAG | NUMBER | This Flag Indicates if this is a Primary Co-product in a Group. | ||
| CONTRIBUTE_TO_STEP_QTY | NUMBER | 1 yes, 2 No. Indicates whether component contributes to step quantity calculations | ||
| OLD_COMPONENT_SEQUENCE_ID | NUMBER | |||
| OPERATION_SEQ_NUM | NUMBER |
Cut, paste (and edit) the following text to query this object:
SELECT PLAN_ID
, COMPONENT_SEQUENCE_ID
, BILL_SEQUENCE_ID
, SR_INSTANCE_ID
, ORGANIZATION_ID
, INVENTORY_ITEM_ID
, USING_ASSEMBLY_ID
, COMPONENT_TYPE
, SCALING_TYPE
, CHANGE_NOTICE
, REVISION
, UOM_CODE
, USAGE_QUANTITY
, EFFECTIVITY_DATE
, DISABLE_DATE
, FROM_UNIT_NUMBER
, TO_UNIT_NUMBER
, USE_UP_CODE
, SUGGESTED_EFFECTIVITY_DATE
, DRIVING_ITEM_ID
, OPERATION_OFFSET_PERCENT
, OPTIONAL_COMPONENT
, OLD_EFFECTIVITY_DATE
, WIP_SUPPLY_TYPE
, PLANNING_FACTOR
, ATP_FLAG
, COMPONENT_YIELD_FACTOR
, REFRESH_NUMBER
, LAST_UPDATE_DATE
, LAST_UPDATED_BY
, CREATION_DATE
, CREATED_BY
, LAST_UPDATE_LOGIN
, REQUEST_ID
, PROGRAM_APPLICATION_ID
, PROGRAM_ID
, PROGRAM_UPDATE_DATE
, ATTRIBUTE_CATEGORY
, ATTRIBUTE1
, ATTRIBUTE2
, ATTRIBUTE3
, ATTRIBUTE4
, ATTRIBUTE5
, ATTRIBUTE6
, ATTRIBUTE7
, ATTRIBUTE8
, ATTRIBUTE9
, ATTRIBUTE10
, ATTRIBUTE11
, ATTRIBUTE12
, ATTRIBUTE13
, ATTRIBUTE14
, ATTRIBUTE15
, SCALE_MULTIPLE
, SCALE_ROUNDING_VARIANCE
, ROUNDING_DIRECTION
, PRIMARY_FLAG
, CONTRIBUTE_TO_STEP_QTY
, OLD_COMPONENT_SEQUENCE_ID
, OPERATION_SEQ_NUM
FROM MSC.MSC_BOM_COMPONENTS;
MSC.MSC_BOM_COMPONENTS does not reference any database object
MSC.MSC_BOM_COMPONENTS is referenced by following:
APPS
MSC_BOM_COMPONENTS
|
|
|
|