DBA Data[Home] [Help]

APPS.CSD_OM_INTERFACE_PVT dependencies on FND_LOG

Line 12: G_debug_level number := FND_LOG.G_CURRENT_RUNTIME_LEVEL;

8: G_PKG_NAME CONSTANT VARCHAR2(30) := 'CSD_OM_INTERFACE_PVT';
9: G_FILE_NAME CONSTANT VARCHAR2(30) := 'csdvomtb.pls';
10:
11: -- Global variable for storing the debug level
12: G_debug_level number := FND_LOG.G_CURRENT_RUNTIME_LEVEL;
13:
14: /*-------------------------------------------------------------------------------------*/
15: /* Function name: DEBUG */
16: /* Description : Logs the debug message */

Line 38: -- Variables used in FND Log

34: p_mod_name in varchar2,
35: p_severity_level in number
36: ) IS
37:
38: -- Variables used in FND Log
39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;
40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;

Line 39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;

35: p_severity_level in number
36: ) IS
37:
38: -- Variables used in FND Log
39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;
40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;
43: l_error_level number := FND_LOG.LEVEL_ERROR;

Line 40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;

36: ) IS
37:
38: -- Variables used in FND Log
39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;
40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;
43: l_error_level number := FND_LOG.LEVEL_ERROR;
44: l_unexp_level number := FND_LOG.LEVEL_UNEXPECTED;

Line 41: l_event_level number := FND_LOG.LEVEL_EVENT;

37:
38: -- Variables used in FND Log
39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;
40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;
43: l_error_level number := FND_LOG.LEVEL_ERROR;
44: l_unexp_level number := FND_LOG.LEVEL_UNEXPECTED;
45:

Line 42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;

38: -- Variables used in FND Log
39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;
40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;
43: l_error_level number := FND_LOG.LEVEL_ERROR;
44: l_unexp_level number := FND_LOG.LEVEL_UNEXPECTED;
45:
46: BEGIN

Line 43: l_error_level number := FND_LOG.LEVEL_ERROR;

39: l_stat_level number := FND_LOG.LEVEL_STATEMENT;
40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;
43: l_error_level number := FND_LOG.LEVEL_ERROR;
44: l_unexp_level number := FND_LOG.LEVEL_UNEXPECTED;
45:
46: BEGIN
47:

Line 44: l_unexp_level number := FND_LOG.LEVEL_UNEXPECTED;

40: l_proc_level number := FND_LOG.LEVEL_PROCEDURE;
41: l_event_level number := FND_LOG.LEVEL_EVENT;
42: l_excep_level number := FND_LOG.LEVEL_EXCEPTION;
43: l_error_level number := FND_LOG.LEVEL_ERROR;
44: l_unexp_level number := FND_LOG.LEVEL_UNEXPECTED;
45:
46: BEGIN
47:
48: IF p_severity_level = 1 THEN

Line 50: FND_LOG.STRING(l_stat_level,p_mod_name,p_message);

46: BEGIN
47:
48: IF p_severity_level = 1 THEN
49: IF ( l_stat_level >= G_debug_level) THEN
50: FND_LOG.STRING(l_stat_level,p_mod_name,p_message);
51: END IF;
52: ELSIF p_severity_level = 2 THEN
53: IF ( l_proc_level >= G_debug_level) THEN
54: FND_LOG.STRING(l_proc_level,p_mod_name,p_message);

Line 54: FND_LOG.STRING(l_proc_level,p_mod_name,p_message);

50: FND_LOG.STRING(l_stat_level,p_mod_name,p_message);
51: END IF;
52: ELSIF p_severity_level = 2 THEN
53: IF ( l_proc_level >= G_debug_level) THEN
54: FND_LOG.STRING(l_proc_level,p_mod_name,p_message);
55: END IF;
56: ELSIF p_severity_level = 3 THEN
57: IF ( l_event_level >= G_debug_level) THEN
58: FND_LOG.STRING(l_event_level,p_mod_name,p_message);

Line 58: FND_LOG.STRING(l_event_level,p_mod_name,p_message);

54: FND_LOG.STRING(l_proc_level,p_mod_name,p_message);
55: END IF;
56: ELSIF p_severity_level = 3 THEN
57: IF ( l_event_level >= G_debug_level) THEN
58: FND_LOG.STRING(l_event_level,p_mod_name,p_message);
59: END IF;
60: ELSIF p_severity_level = 4 THEN
61: IF ( l_excep_level >= G_debug_level) THEN
62: FND_LOG.STRING(l_excep_level,p_mod_name,p_message);

Line 62: FND_LOG.STRING(l_excep_level,p_mod_name,p_message);

58: FND_LOG.STRING(l_event_level,p_mod_name,p_message);
59: END IF;
60: ELSIF p_severity_level = 4 THEN
61: IF ( l_excep_level >= G_debug_level) THEN
62: FND_LOG.STRING(l_excep_level,p_mod_name,p_message);
63: END IF;
64: ELSIF p_severity_level = 5 THEN
65: IF ( l_error_level >= G_debug_level) THEN
66: FND_LOG.STRING(l_error_level,p_mod_name,p_message);

Line 66: FND_LOG.STRING(l_error_level,p_mod_name,p_message);

62: FND_LOG.STRING(l_excep_level,p_mod_name,p_message);
63: END IF;
64: ELSIF p_severity_level = 5 THEN
65: IF ( l_error_level >= G_debug_level) THEN
66: FND_LOG.STRING(l_error_level,p_mod_name,p_message);
67: END IF;
68: ELSIF p_severity_level = 6 THEN
69: IF ( l_unexp_level >= G_debug_level) THEN
70: FND_LOG.STRING(l_unexp_level,p_mod_name,p_message);

Line 70: FND_LOG.STRING(l_unexp_level,p_mod_name,p_message);

66: FND_LOG.STRING(l_error_level,p_mod_name,p_message);
67: END IF;
68: ELSIF p_severity_level = 6 THEN
69: IF ( l_unexp_level >= G_debug_level) THEN
70: FND_LOG.STRING(l_unexp_level,p_mod_name,p_message);
71: END IF;
72: END IF;
73:
74: END DEBUG;

Line 108: -- Variables used in FND Log

104:
105: l_party_site_id NUMBER;
106: l_party_site_use_id NUMBER;
107:
108: -- Variables used in FND Log
109: l_error_level number := FND_LOG.LEVEL_ERROR;
110: l_mod_name varchar2(2000) := 'csd.plsql.csd_om_interface_pvt.get_party_site_id';
111:
112: BEGIN

Line 109: l_error_level number := FND_LOG.LEVEL_ERROR;

105: l_party_site_id NUMBER;
106: l_party_site_use_id NUMBER;
107:
108: -- Variables used in FND Log
109: l_error_level number := FND_LOG.LEVEL_ERROR;
110: l_mod_name varchar2(2000) := 'csd.plsql.csd_om_interface_pvt.get_party_site_id';
111:
112: BEGIN
113: -- Initialize the return status

Line 132: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

128: When No_Data_found then
129: IF ( l_error_level >= G_debug_level) THEN
130: fnd_message.set_name('CSD','CSD_INV_PTY_SITE_USE_ID');
131: fnd_message.set_token('CUST_SITE_USE_ID',p_cust_site_use_id );
132: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
133: ELSE
134: fnd_message.set_name('CSD','CSD_INV_PTY_SITE_USE_ID');
135: fnd_message.set_token('CUST_SITE_USE_ID',p_cust_site_use_id );
136: fnd_msg_pub.add;

Line 159: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

155: When No_Data_found then
156: IF ( l_error_level >= G_debug_level) THEN
157: fnd_message.set_name('CSD','CSD_INV_PTY_SITE_ID');
158: fnd_message.set_token('PTY_SITE_ID',l_party_site_id);
159: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
160: ELSE
161: fnd_message.set_name('CSD','CSD_INV_PTY_SITE_ID');
162: fnd_message.set_token('PTY_SITE_ID',l_party_site_id);
163: fnd_msg_pub.add;

Line 171: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

167: When TOO_MANY_ROWS then
168: IF ( l_error_level >= G_debug_level) THEN
169: fnd_message.set_name('CSD','CSD_INV_PTY_SITE_ID');
170: fnd_message.set_token('PTY_SITE_ID',l_party_site_id);
171: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
172: ELSE
173: fnd_message.set_name('CSD','CSD_INV_PTY_SITE_ID');
174: fnd_message.set_token('PTY_SITE_ID',l_party_site_id);
175: fnd_msg_pub.add;

Line 335: -- Variables used in FND Log

331: SELECT serial_num
332: from rcv_serial_transactions
333: where transaction_id = p_txn_id;
334:
335: -- Variables used in FND Log
336: l_error_level number := FND_LOG.LEVEL_ERROR;
337: l_mod_name varchar2(2000) := 'csd.plsql.csd_om_interface_pvt.process_rma';
338:
339: BEGIN

Line 336: l_error_level number := FND_LOG.LEVEL_ERROR;

332: from rcv_serial_transactions
333: where transaction_id = p_txn_id;
334:
335: -- Variables used in FND Log
336: l_error_level number := FND_LOG.LEVEL_ERROR;
337: l_mod_name varchar2(2000) := 'csd.plsql.csd_om_interface_pvt.process_rma';
338:
339: BEGIN
340:

Line 363: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

359: IF p_inventory_org_id is NULL OR
360: p_subinventory_name is NULL then
361: IF ( l_error_level >= G_debug_level) THEN
362: fnd_message.set_name('CSD','CSD_PARAMETERS_MISSING');
363: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
364: ELSE
365: fnd_message.set_name('CSD','CSD_PARAMETERS_MISSING');
366: fnd_msg_pub.add;
367: END IF;

Line 400: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

396: l_inc_urgency_id is NULL OR
397: l_inc_work_summary is NULL THEN
398: IF ( l_error_level >= G_debug_level) THEN
399: fnd_message.set_name('CSD','CSD_PROF_SETUP_MISSING');
400: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
401: ELSE
402: fnd_message.set_name('CSD','CSD_PROF_SETUP_MISSING');
403: fnd_msg_pub.add;
404: END IF;

Line 425: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

421: Exception
422: When No_Data_found then
423: IF ( l_error_level >= G_debug_level) THEN
424: fnd_message.set_name('CSD','CSD_STD_REP_TYPE_MISSING');
425: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
426: ELSE
427: fnd_message.set_name('CSD','CSD_STD_REP_TYPE_MISSING');
428: fnd_msg_pub.add;
429: END IF;

Line 435: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

431: Raise FND_API.G_EXC_ERROR ;
432: When TOO_MANY_ROWS then
433: IF ( l_error_level >= G_debug_level) THEN
434: fnd_message.set_name('CSD','CSD_STD_REP_TYPE_MISSING');
435: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
436: ELSE
437: fnd_message.set_name('CSD','CSD_STD_REP_TYPE_MISSING');
438: fnd_msg_pub.add;
439: END IF;

Line 456: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

452: When No_Data_found then
453: IF ( l_error_level >= G_debug_level) THEN
454: fnd_message.set_name('CSD','CSD_INVALID_INV_ORG_ID');
455: fnd_message.set_token('INV_ORG_ID',p_inventory_org_id);
456: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
457: ELSE
458: fnd_message.set_name('CSD','CSD_INVALID_INV_ORG_ID');
459: fnd_message.set_token('INV_ORG_ID',p_inventory_org_id);
460: fnd_msg_pub.add;

Line 468: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

464: When TOO_MANY_ROWS then
465: IF ( l_error_level >= G_debug_level) THEN
466: fnd_message.set_name('CSD','CSD_INVALID_INV_ORG_ID');
467: fnd_message.set_token('INV_ORG_ID',p_inventory_org_id);
468: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
469: ELSE
470: fnd_message.set_name('CSD','CSD_INVALID_INV_ORG_ID');
471: fnd_message.set_token('INV_ORG_ID',p_inventory_org_id);
472: fnd_msg_pub.add;

Line 491: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

487: When No_Data_found then
488: IF ( l_error_level >= G_debug_level) THEN
489: fnd_message.set_name('CSD','CSD_INVALID_SUB_INV');
490: fnd_message.set_token('SUB_INV',p_subinventory_name );
491: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
492: ELSE
493: fnd_message.set_name('CSD','CSD_INVALID_SUB_INV');
494: fnd_message.set_token('SUB_INV',p_subinventory_name );
495: fnd_msg_pub.add;

Line 503: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

499: When TOO_MANY_ROWS then
500: IF ( l_error_level >= G_debug_level) THEN
501: fnd_message.set_name('CSD','CSD_INVALID_SUB_INV');
502: fnd_message.set_token('SUB_INV',p_subinventory_name );
503: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
504: ELSE
505: fnd_message.set_name('CSD','CSD_INVALID_SUB_INV');
506: fnd_message.set_token('SUB_INV',p_subinventory_name );
507: fnd_msg_pub.add;

Line 734: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

730: When No_Data_Found then
731: IF ( l_error_level >= G_debug_level) THEN
732: fnd_message.set_name('CSD','CSD_INV_ITEM_ID');
733: fnd_message.set_token('ITEM_ID',c1.inventory_item_id);
734: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
735: ELSE
736: fnd_message.set_name('CSD','CSD_INV_ITEM_ID');
737: fnd_message.set_token('ITEM_ID',c1.inventory_item_id);
738: fnd_msg_pub.add;

Line 798: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);

794: When No_Data_Found then
795: IF ( l_error_level >= G_debug_level) THEN
796: fnd_message.set_name('CSD','CSD_IB_INSTANCE_MISSING');
797: fnd_message.set_token('SERIAL_NUM', C2.serial_num);
798: FND_LOG.MESSAGE(l_error_level,l_mod_name, FALSE);
799: ELSE
800: fnd_message.set_name('CSD','CSD_IB_INSTANCE_MISSING');
801: fnd_message.set_token('SERIAL_NUM', C2.serial_num);
802: fnd_msg_pub.add;

Line 1114: -- Variables used in FND Log

1110:
1111: l_contacts_table CS_ServiceRequest_PUB.contacts_table;
1112: i NUMBER;
1113:
1114: -- Variables used in FND Log
1115: l_error_level number := FND_LOG.LEVEL_ERROR;
1116: l_mod_name varchar2(2000) := 'csd.plsql.csd_om_interface_pvt.get_sr_contacts';
1117:
1118: BEGIN

Line 1115: l_error_level number := FND_LOG.LEVEL_ERROR;

1111: l_contacts_table CS_ServiceRequest_PUB.contacts_table;
1112: i NUMBER;
1113:
1114: -- Variables used in FND Log
1115: l_error_level number := FND_LOG.LEVEL_ERROR;
1116: l_mod_name varchar2(2000) := 'csd.plsql.csd_om_interface_pvt.get_sr_contacts';
1117:
1118: BEGIN
1119: Debug( 'At the Beginning of GET_SR_CONTACTS',l_mod_name,1);