DBA Data[Home] [Help]

APPS.AS_UTILITY_PVT dependencies on FND_LOG

Line 48: l_level := FND_LOG.LEVEL_ERROR;

44: FUNCTION translate_log_level(p_old_level NUMBER) RETURN NUMBER IS
45: l_level NUMBER;
46: BEGIN
47: if p_old_level = FND_MSG_PUB.G_MSG_LVL_ERROR then
48: l_level := FND_LOG.LEVEL_ERROR;
49: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
50: l_level := FND_LOG.LEVEL_UNEXPECTED;
51: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
52: l_level := FND_LOG.LEVEL_EVENT;

Line 50: l_level := FND_LOG.LEVEL_UNEXPECTED;

46: BEGIN
47: if p_old_level = FND_MSG_PUB.G_MSG_LVL_ERROR then
48: l_level := FND_LOG.LEVEL_ERROR;
49: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
50: l_level := FND_LOG.LEVEL_UNEXPECTED;
51: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
52: l_level := FND_LOG.LEVEL_EVENT;
53: else
54: l_level := FND_LOG.LEVEL_STATEMENT;

Line 52: l_level := FND_LOG.LEVEL_EVENT;

48: l_level := FND_LOG.LEVEL_ERROR;
49: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
50: l_level := FND_LOG.LEVEL_UNEXPECTED;
51: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
52: l_level := FND_LOG.LEVEL_EVENT;
53: else
54: l_level := FND_LOG.LEVEL_STATEMENT;
55: end if;
56:

Line 54: l_level := FND_LOG.LEVEL_STATEMENT;

50: l_level := FND_LOG.LEVEL_UNEXPECTED;
51: elsif p_old_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
52: l_level := FND_LOG.LEVEL_EVENT;
53: else
54: l_level := FND_LOG.LEVEL_STATEMENT;
55: end if;
56:
57: RETURN l_level;
58: END;

Line 64: if FND_LOG.LEVEL_ERROR >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

60: -- The following procedure have added for common logging enhancement
61: PROCEDURE SET_LOG(p_module VARCHAR2, p_level NUMBER) is
62: BEGIN
63: if p_level = FND_MSG_PUB.G_MSG_LVL_ERROR then
64: if FND_LOG.LEVEL_ERROR >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
65: fnd_log.message(FND_LOG.LEVEL_ERROR,p_module,TRUE);
66: end if;
67: elsif p_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
68: if FND_LOG.LEVEL_UNEXPECTED >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

Line 65: fnd_log.message(FND_LOG.LEVEL_ERROR,p_module,TRUE);

61: PROCEDURE SET_LOG(p_module VARCHAR2, p_level NUMBER) is
62: BEGIN
63: if p_level = FND_MSG_PUB.G_MSG_LVL_ERROR then
64: if FND_LOG.LEVEL_ERROR >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
65: fnd_log.message(FND_LOG.LEVEL_ERROR,p_module,TRUE);
66: end if;
67: elsif p_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
68: if FND_LOG.LEVEL_UNEXPECTED >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
69: fnd_log.message(FND_LOG.LEVEL_UNEXPECTED,p_module,TRUE);

Line 68: if FND_LOG.LEVEL_UNEXPECTED >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

64: if FND_LOG.LEVEL_ERROR >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
65: fnd_log.message(FND_LOG.LEVEL_ERROR,p_module,TRUE);
66: end if;
67: elsif p_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
68: if FND_LOG.LEVEL_UNEXPECTED >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
69: fnd_log.message(FND_LOG.LEVEL_UNEXPECTED,p_module,TRUE);
70: end if;
71: elsif p_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
72: if FND_LOG.LEVEL_EVENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

Line 69: fnd_log.message(FND_LOG.LEVEL_UNEXPECTED,p_module,TRUE);

65: fnd_log.message(FND_LOG.LEVEL_ERROR,p_module,TRUE);
66: end if;
67: elsif p_level = FND_MSG_PUB.G_MSG_LVL_UNEXP_ERROR then
68: if FND_LOG.LEVEL_UNEXPECTED >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
69: fnd_log.message(FND_LOG.LEVEL_UNEXPECTED,p_module,TRUE);
70: end if;
71: elsif p_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
72: if FND_LOG.LEVEL_EVENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
73: fnd_log.message(FND_LOG.LEVEL_EVENT,p_module,TRUE);

Line 72: if FND_LOG.LEVEL_EVENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

68: if FND_LOG.LEVEL_UNEXPECTED >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
69: fnd_log.message(FND_LOG.LEVEL_UNEXPECTED,p_module,TRUE);
70: end if;
71: elsif p_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
72: if FND_LOG.LEVEL_EVENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
73: fnd_log.message(FND_LOG.LEVEL_EVENT,p_module,TRUE);
74: end if;
75: else
76: if FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

Line 73: fnd_log.message(FND_LOG.LEVEL_EVENT,p_module,TRUE);

69: fnd_log.message(FND_LOG.LEVEL_UNEXPECTED,p_module,TRUE);
70: end if;
71: elsif p_level = FND_MSG_PUB.G_MSG_LVL_SUCCESS then
72: if FND_LOG.LEVEL_EVENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
73: fnd_log.message(FND_LOG.LEVEL_EVENT,p_module,TRUE);
74: end if;
75: else
76: if FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
77: fnd_log.message(FND_LOG.LEVEL_STATEMENT,p_module,TRUE);

Line 76: if FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then

72: if FND_LOG.LEVEL_EVENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
73: fnd_log.message(FND_LOG.LEVEL_EVENT,p_module,TRUE);
74: end if;
75: else
76: if FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
77: fnd_log.message(FND_LOG.LEVEL_STATEMENT,p_module,TRUE);
78: end if;
79: end if;
80: END SET_LOG;

Line 77: fnd_log.message(FND_LOG.LEVEL_STATEMENT,p_module,TRUE);

73: fnd_log.message(FND_LOG.LEVEL_EVENT,p_module,TRUE);
74: end if;
75: else
76: if FND_LOG.LEVEL_STATEMENT >= FND_LOG.G_CURRENT_RUNTIME_LEVEL then
77: fnd_log.message(FND_LOG.LEVEL_STATEMENT,p_module,TRUE);
78: end if;
79: end if;
80: END SET_LOG;
81:

Line 167: IF l_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL THEN

163: THEN
164: x_return_status := FND_API.G_RET_STS_UNEXP_ERROR;
165:
166: l_log_level := translate_log_level(p_exception_level);
167: IF l_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL THEN
168: FND_MESSAGE.Set_Name('AS', 'Error number ' || to_char(P_SQLCODE));
169: FND_MSG_PUB.Add;
170: FND_MESSAGE.Set_Name('AS', 'Error number ' || to_char(P_SQLCODE));
171: SET_LOG(p_module, p_exception_level);

Line 492: IF l_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL THEN

488: FND_MSG_PUB.Add;
489:
490: */
491: l_log_level := translate_log_level(p_msg_level);
492: IF l_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL THEN
493: l_length := length(p_msg);
494:
495: -- FND_MESSAGE doesn't allow application name to be over 30 chars
496: -- chop message name if length > 30