DBA Data[Home] [Help]

APPS.AHL_WARRANTY_ENTL_PVT dependencies on FND_LOG

Line 10: l_log_current_level NUMBER := FND_LOG.g_current_runtime_level;

6:
7: ------------------------------------------------------------------------------------
8: -- Common constants and variables
9: ------------------------------------------------------------------------------------
10: l_log_current_level NUMBER := FND_LOG.g_current_runtime_level;
11: l_log_statement NUMBER := FND_LOG.level_statement;
12: l_log_procedure NUMBER := FND_LOG.level_procedure;
13: l_log_error NUMBER := FND_LOG.level_error;
14: l_log_exception NUMBER := FND_LOG.level_exception;

Line 11: l_log_statement NUMBER := FND_LOG.level_statement;

7: ------------------------------------------------------------------------------------
8: -- Common constants and variables
9: ------------------------------------------------------------------------------------
10: l_log_current_level NUMBER := FND_LOG.g_current_runtime_level;
11: l_log_statement NUMBER := FND_LOG.level_statement;
12: l_log_procedure NUMBER := FND_LOG.level_procedure;
13: l_log_error NUMBER := FND_LOG.level_error;
14: l_log_exception NUMBER := FND_LOG.level_exception;
15: l_log_unexpected NUMBER := FND_LOG.level_unexpected;

Line 12: l_log_procedure NUMBER := FND_LOG.level_procedure;

8: -- Common constants and variables
9: ------------------------------------------------------------------------------------
10: l_log_current_level NUMBER := FND_LOG.g_current_runtime_level;
11: l_log_statement NUMBER := FND_LOG.level_statement;
12: l_log_procedure NUMBER := FND_LOG.level_procedure;
13: l_log_error NUMBER := FND_LOG.level_error;
14: l_log_exception NUMBER := FND_LOG.level_exception;
15: l_log_unexpected NUMBER := FND_LOG.level_unexpected;
16: ------------------------------------------------------------------------------------

Line 13: l_log_error NUMBER := FND_LOG.level_error;

9: ------------------------------------------------------------------------------------
10: l_log_current_level NUMBER := FND_LOG.g_current_runtime_level;
11: l_log_statement NUMBER := FND_LOG.level_statement;
12: l_log_procedure NUMBER := FND_LOG.level_procedure;
13: l_log_error NUMBER := FND_LOG.level_error;
14: l_log_exception NUMBER := FND_LOG.level_exception;
15: l_log_unexpected NUMBER := FND_LOG.level_unexpected;
16: ------------------------------------------------------------------------------------
17:

Line 14: l_log_exception NUMBER := FND_LOG.level_exception;

10: l_log_current_level NUMBER := FND_LOG.g_current_runtime_level;
11: l_log_statement NUMBER := FND_LOG.level_statement;
12: l_log_procedure NUMBER := FND_LOG.level_procedure;
13: l_log_error NUMBER := FND_LOG.level_error;
14: l_log_exception NUMBER := FND_LOG.level_exception;
15: l_log_unexpected NUMBER := FND_LOG.level_unexpected;
16: ------------------------------------------------------------------------------------
17:
18: ------------------------------------------------------------------------------------

Line 15: l_log_unexpected NUMBER := FND_LOG.level_unexpected;

11: l_log_statement NUMBER := FND_LOG.level_statement;
12: l_log_procedure NUMBER := FND_LOG.level_procedure;
13: l_log_error NUMBER := FND_LOG.level_error;
14: l_log_exception NUMBER := FND_LOG.level_exception;
15: l_log_unexpected NUMBER := FND_LOG.level_unexpected;
16: ------------------------------------------------------------------------------------
17:
18: ------------------------------------------------------------------------------------
19: -- Private procedure prototypes

Line 97: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'At the start of the API');

93: --
94:
95: BEGIN
96: IF (l_log_procedure >= l_log_current_level) THEN
97: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'At the start of the API');
98: END IF;
99:
100: -- Standard start of API savepoint
101: SAVEPOINT Process_Warranty_Entl_Pub;

Line 118: FND_LOG.string(l_log_statement, l_full_name, 'l_warranty_entl_tbl.COUNT = '|| l_warranty_entl_tbl.COUNT);

114: -- Initialize Procedure return status to success
115: x_return_status := FND_API.G_RET_STS_SUCCESS;
116:
117: IF (l_log_statement >= l_log_current_level) THEN
118: FND_LOG.string(l_log_statement, l_full_name, 'l_warranty_entl_tbl.COUNT = '|| l_warranty_entl_tbl.COUNT);
119: END IF;
120:
121: -- Get the error message count till this point
122: l_msg_count := FND_MSG_PUB.count_msg;

Line 129: FND_LOG.string(l_log_statement, l_full_name, 'operation '||l_warranty_entl_tbl(i).operation_flag||

125: IF (l_warranty_entl_tbl.COUNT >= 1) THEN
126: FOR i IN l_warranty_entl_tbl.FIRST..l_warranty_entl_tbl.LAST LOOP
127:
128: IF (l_log_statement >= l_log_current_level) THEN
129: FND_LOG.string(l_log_statement, l_full_name, 'operation '||l_warranty_entl_tbl(i).operation_flag||
130: ' for record# '||i);
131: END IF;
132:
133: -- Check for the operation associated to the record.

Line 170: FND_LOG.string(l_log_statement, l_full_name, 'Process_Warranty_Entitlements errored out');

166:
167: -- If any errors occured, then raise them
168: IF (l_msg_count < FND_MSG_PUB.count_msg) THEN
169: IF (l_log_statement >= l_log_current_level) THEN
170: FND_LOG.string(l_log_statement, l_full_name, 'Process_Warranty_Entitlements errored out');
171: END IF;
172: RAISE FND_API.G_EXC_ERROR;
173: END IF;
174:

Line 181: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'At the end of the API');

177: COMMIT WORK;
178: END IF;
179:
180: IF (l_log_procedure >= l_log_current_level) THEN
181: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'At the end of the API');
182: END IF;
183:
184: EXCEPTION
185: WHEN FND_API.G_EXC_ERROR THEN

Line 192: FND_LOG.string(l_log_exception, l_full_name, 'Execution Error: ' || x_msg_data);

188: FND_MSG_PUB.count_and_get( p_count => x_msg_count,
189: p_data => x_msg_data,
190: p_encoded => FND_API.G_FALSE);
191: IF (l_log_exception >= l_log_current_level) THEN
192: FND_LOG.string(l_log_exception, l_full_name, 'Execution Error: ' || x_msg_data);
193: END IF;
194:
195: WHEN FND_API.G_EXC_UNEXPECTED_ERROR THEN
196: ROLLBACK TO Process_Warranty_Entl_Pub;

Line 202: FND_LOG.string(l_log_unexpected, l_full_name, 'Unexpected Exception: ' || x_msg_data);

198: FND_MSG_PUB.count_and_get( p_count => x_msg_count,
199: p_data => x_msg_data,
200: p_encoded => FND_API.G_FALSE);
201: IF (l_log_unexpected >= l_log_current_level) THEN
202: FND_LOG.string(l_log_unexpected, l_full_name, 'Unexpected Exception: ' || x_msg_data);
203: END IF;
204:
205: WHEN OTHERS THEN
206: ROLLBACK TO Process_Warranty_Entl_Pub;

Line 217: FND_LOG.string(l_log_unexpected, l_full_name, 'Other Exception: ' || x_msg_data);

213: FND_MSG_PUB.count_and_get(p_count => x_msg_count,
214: p_data => x_msg_data,
215: p_encoded => fnd_api.G_FALSE);
216: IF (l_log_unexpected >= l_log_current_level) THEN
217: FND_LOG.string(l_log_unexpected, l_full_name, 'Other Exception: ' || x_msg_data);
218: END IF;
219:
220: END Process_Warranty_Entitlements;
221: ------------------------------------------------------------------------------------

Line 331: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'At the start of the API');

327: --
328:
329: BEGIN
330: IF (l_log_procedure >= l_log_current_level) THEN
331: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'At the start of the API');
332: END IF;
333:
334: -- initialize procedure return status to success
335: x_return_status := FND_API.G_RET_STS_SUCCESS;

Line 338: FND_LOG.string(l_log_statement, l_full_name, 'the arguments: '||

334: -- initialize procedure return status to success
335: x_return_status := FND_API.G_RET_STS_SUCCESS;
336:
337: IF (l_log_statement >= l_log_current_level) THEN
338: FND_LOG.string(l_log_statement, l_full_name, 'the arguments: '||
339: ' p_entitlement_id > '||p_entitlement_id||
340: ', p_commit > '||p_commit);
341: END IF;
342:

Line 363: FND_LOG.string(l_log_statement, l_full_name, 'the returned values from AHL_UTILITY_PVT.Get_WF_Process_Name : '||

359: x_msg_data => l_msg_data,
360: x_return_status => x_return_status);
361:
362: IF (l_log_statement >= l_log_current_level) THEN
363: FND_LOG.string(l_log_statement, l_full_name, 'the returned values from AHL_UTILITY_PVT.Get_WF_Process_Name : '||
364: ' l_active_flag > '||l_active_flag||
365: ', l_process_name > '||l_process_name||
366: ', l_item_type > '||l_item_type||
367: ', x_return_status > '||x_return_status);

Line 381: FND_LOG.string(l_log_statement, l_full_name,

377: -- get the subject text
378: l_subject := FND_MESSAGE.GET_STRING(G_APP_NAME, G_WARRANTY_ENTL_SBJ);
379:
380: IF (l_log_statement >= l_log_current_level) THEN
381: FND_LOG.string(l_log_statement, l_full_name,
382: 'before calling AHL_WF_NOTIFICATION_PVT.Launch_OA_Notification with arguments: '||
383: ' p_object > '||G_WF_ENTL_OBJ||
384: ', p_process_name > '||l_process_name||
385: ', p_item_type > '||l_item_type||

Line 405: FND_LOG.string(l_log_statement, l_full_name,

401: x_item_key => x_item_key,
402: x_return_status => x_return_status);
403:
404: IF (l_log_statement >= l_log_current_level) THEN
405: FND_LOG.string(l_log_statement, l_full_name,
406: 'after calling AHL_WF_NOTIFICATION_PVT.Launch_OA_Notification, '||
407: ' x_item_key > '||x_item_key||
408: ', x_return_status > '||x_return_status);
409: END IF;

Line 423: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'At the end of the API');

419: COMMIT WORK;
420: END IF;
421:
422: IF (l_log_procedure >= l_log_current_level) THEN
423: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'At the end of the API');
424: END IF;
425:
426: END Launch_Entl_Notification;
427: ------------------------------------------------------------------------------------

Line 777: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

773: --
774:
775: BEGIN
776: IF (l_log_procedure >= l_log_current_level) THEN
777: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
778: END IF;
779:
780: IF (l_log_statement >= l_log_current_level) THEN
781: FND_LOG.string(l_log_statement, l_full_name, 'p_entitlement_id > '||p_entitlement_id);

Line 781: FND_LOG.string(l_log_statement, l_full_name, 'p_entitlement_id > '||p_entitlement_id);

777: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
778: END IF;
779:
780: IF (l_log_statement >= l_log_current_level) THEN
781: FND_LOG.string(l_log_statement, l_full_name, 'p_entitlement_id > '||p_entitlement_id);
782: END IF;
783:
784: -- get the instance id from the visit task id
785: OPEN get_visit_task_inst_csr(p_entitlement_id);

Line 790: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);

786: FETCH get_visit_task_inst_csr INTO l_ret_val;
787: CLOSE get_visit_task_inst_csr;
788:
789: IF (l_log_statement >= l_log_current_level) THEN
790: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
791: END IF;
792:
793: -- if not found, then get the instance id from the OSP order line id
794: IF (l_ret_val IS NULL) THEN

Line 801: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);

797: CLOSE get_osp_line_inst_csr;
798: END IF;
799:
800: IF (l_log_statement >= l_log_current_level) THEN
801: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
802: END IF;
803:
804: IF (l_log_procedure >= l_log_current_level) THEN
805: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

Line 805: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

801: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
802: END IF;
803:
804: IF (l_log_procedure >= l_log_current_level) THEN
805: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
806: END IF;
807:
808: RETURN l_ret_val;
809:

Line 848: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

844: --
845:
846: BEGIN
847: IF (l_log_procedure >= l_log_current_level) THEN
848: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
849: END IF;
850:
851: IF (l_log_statement >= l_log_current_level) THEN
852: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);

Line 852: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);

848: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
849: END IF;
850:
851: IF (l_log_statement >= l_log_current_level) THEN
852: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);
853: END IF;
854:
855: -- get the OSP order number for the given OSP line id
856: OPEN get_osp_order_number_csr(p_osp_line_id);

Line 861: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);

857: FETCH get_osp_order_number_csr INTO l_ret_val;
858: CLOSE get_osp_order_number_csr;
859:
860: IF (l_log_statement >= l_log_current_level) THEN
861: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
862: END IF;
863:
864: IF (l_log_procedure >= l_log_current_level) THEN
865: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

Line 865: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

861: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
862: END IF;
863:
864: IF (l_log_procedure >= l_log_current_level) THEN
865: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
866: END IF;
867:
868: RETURN l_ret_val;
869:

Line 907: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

903: --
904:
905: BEGIN
906: IF (l_log_procedure >= l_log_current_level) THEN
907: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
908: END IF;
909:
910: IF (l_log_statement >= l_log_current_level) THEN
911: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);

Line 911: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);

907: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
908: END IF;
909:
910: IF (l_log_statement >= l_log_current_level) THEN
911: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);
912: END IF;
913:
914: -- get the OSP line number for the given OSP line id
915: OPEN get_osp_line_number_csr(p_osp_line_id);

Line 920: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);

916: FETCH get_osp_line_number_csr INTO l_ret_val;
917: CLOSE get_osp_line_number_csr;
918:
919: IF (l_log_statement >= l_log_current_level) THEN
920: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
921: END IF;
922:
923: IF (l_log_procedure >= l_log_current_level) THEN
924: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

Line 924: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

920: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
921: END IF;
922:
923: IF (l_log_procedure >= l_log_current_level) THEN
924: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
925: END IF;
926:
927: RETURN l_ret_val;
928:

Line 968: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

964: --
965:
966: BEGIN
967: IF (l_log_procedure >= l_log_current_level) THEN
968: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
969: END IF;
970:
971: IF (l_log_statement >= l_log_current_level) THEN
972: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);

Line 972: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);

968: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
969: END IF;
970:
971: IF (l_log_statement >= l_log_current_level) THEN
972: FND_LOG.string(l_log_statement, l_full_name, 'p_osp_line_id > '||p_osp_line_id);
973: END IF;
974:
975: -- get the OSP line status for the given OSP line id
976: OPEN get_osp_line_status_csr(p_osp_line_id);

Line 981: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);

977: FETCH get_osp_line_status_csr INTO l_ret_val;
978: CLOSE get_osp_line_status_csr;
979:
980: IF (l_log_statement >= l_log_current_level) THEN
981: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
982: END IF;
983:
984: IF (l_log_procedure >= l_log_current_level) THEN
985: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

Line 985: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

981: FND_LOG.string(l_log_statement, l_full_name, 'l_ret_val > '||l_ret_val);
982: END IF;
983:
984: IF (l_log_procedure >= l_log_current_level) THEN
985: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
986: END IF;
987:
988: RETURN l_ret_val;
989:

Line 1017: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

1013: --
1014:
1015: BEGIN
1016: IF (l_log_procedure >= l_log_current_level) THEN
1017: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
1018: END IF;
1019:
1020: -- module type check commented for present requirements. can be used in future
1021: -- IF (p_module_type = 'JSP') THEN

Line 1117: FND_LOG.string(l_log_statement, l_full_name, 'Validate_Warranty_Entitlement for create had errors');

1113:
1114: -- if any errors occured, then don't proceed any further
1115: IF (l_msg_count < FND_MSG_PUB.count_msg) THEN
1116: IF (l_log_statement >= l_log_current_level) THEN
1117: FND_LOG.string(l_log_statement, l_full_name, 'Validate_Warranty_Entitlement for create had errors');
1118: END IF;
1119: RETURN;
1120: END IF;
1121:

Line 1141: FND_LOG.string(l_log_statement, l_full_name, 'Before Insert_Row');

1137: l_contract_id := NULL;
1138: END IF;
1139:
1140: IF (l_log_statement >= l_log_current_level) THEN
1141: FND_LOG.string(l_log_statement, l_full_name, 'Before Insert_Row');
1142: END IF;
1143:
1144: AHL_WARRANTY_ENTITLEMENTS_PKG.Insert_Row(
1145: x_row_id => l_dummy_char,

Line 1184: FND_LOG.string(l_log_statement, l_full_name, 'After Insert_Row');

1180: x_last_update_login => p_x_warranty_entl_rec.last_update_login
1181: );
1182:
1183: IF (l_log_statement >= l_log_current_level) THEN
1184: FND_LOG.string(l_log_statement, l_full_name, 'After Insert_Row');
1185: END IF;
1186:
1187: -- for non-planner user and Approval Pending status creation, launch the notification
1188: IF (NVL(p_user_role, 'X') = G_USER_NONPLANNER AND

Line 1191: FND_LOG.string(l_log_statement, l_full_name,

1187: -- for non-planner user and Approval Pending status creation, launch the notification
1188: IF (NVL(p_user_role, 'X') = G_USER_NONPLANNER AND
1189: NVL(p_x_warranty_entl_rec.entitlement_status_code, 'X') = 'APPROVAL_PENDING') THEN
1190: IF (l_log_statement >= l_log_current_level) THEN
1191: FND_LOG.string(l_log_statement, l_full_name,
1192: 'before calling Launch_Entl_Notification with arguments: '||
1193: ' p_entitlement_id > '||p_x_warranty_entl_rec.warranty_entitlement_id);
1194: END IF;
1195:

Line 1205: FND_LOG.string(l_log_statement, l_full_name,

1201: x_item_key => l_item_key,
1202: x_return_status => l_return_status);
1203:
1204: IF (l_log_statement >= l_log_current_level) THEN
1205: FND_LOG.string(l_log_statement, l_full_name,
1206: 'after calling Launch_Entl_Notification, '||
1207: ' l_item_key > '||l_item_key||
1208: ', l_return_status'||l_return_status);
1209: END IF;

Line 1213: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

1209: END IF;
1210: END IF;
1211:
1212: IF (l_log_procedure >= l_log_current_level) THEN
1213: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
1214: END IF;
1215: END Create_Warranty_Entitlement;
1216: ------------------------------------------------------------------------------------
1217:

Line 1243: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

1239: --
1240:
1241: BEGIN
1242: IF (l_log_procedure >= l_log_current_level) THEN
1243: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
1244: END IF;
1245:
1246: OPEN warranty_entl_csr(p_x_warranty_entl_rec.warranty_entitlement_id);
1247: FETCH warranty_entl_csr INTO l_warranty_entl_rec;

Line 1251: FND_LOG.string(l_log_statement, l_full_name, 'invalid entitlement id for update');

1247: FETCH warranty_entl_csr INTO l_warranty_entl_rec;
1248: IF (warranty_entl_csr%NOTFOUND) THEN
1249: -- invalid entitlement id
1250: IF (l_log_statement >= l_log_current_level) THEN
1251: FND_LOG.string(l_log_statement, l_full_name, 'invalid entitlement id for update');
1252: END IF;
1253: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_ENTL_ID_INVLD'); -- Warranty entitlement id ENTL_ID is invalid.
1254: FND_MESSAGE.Set_Token('ENTL_ID', p_x_warranty_entl_rec.warranty_entitlement_id);
1255: FND_MSG_PUB.ADD;

Line 1263: FND_LOG.string(l_log_statement, l_full_name, 'object_version_number mismatch');

1259:
1260: -- check for object_version_number
1261: IF (p_x_warranty_entl_rec.object_version_number <> l_warranty_entl_rec.object_version_number) THEN
1262: IF (l_log_statement >= l_log_current_level) THEN
1263: FND_LOG.string(l_log_statement, l_full_name, 'object_version_number mismatch');
1264: END IF;
1265: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_COM_RECORD_CHANGED'); -- Record has been modified by another user.
1266: FND_MSG_PUB.ADD;
1267: RETURN;

Line 1421: FND_LOG.string(l_log_statement, l_full_name, 'Validate_Warranty_Entitlement for update had errors');

1417:
1418: -- if any errors occured, then don't proceed any further
1419: IF (l_msg_count < FND_MSG_PUB.count_msg) THEN
1420: IF (l_log_statement >= l_log_current_level) THEN
1421: FND_LOG.string(l_log_statement, l_full_name, 'Validate_Warranty_Entitlement for update had errors');
1422: END IF;
1423: RETURN;
1424: END IF;
1425:

Line 1441: FND_LOG.string(l_log_statement, l_full_name, 'Before Update_Row');

1437: l_contract_id := l_warranty_entl_rec.old_warranty_contract_id;
1438: END IF;
1439:
1440: IF (l_log_statement >= l_log_current_level) THEN
1441: FND_LOG.string(l_log_statement, l_full_name, 'Before Update_Row');
1442: END IF;
1443:
1444: AHL_WARRANTY_ENTITLEMENTS_PKG.Update_Row(
1445: x_warranty_entitlement_id => p_x_warranty_entl_rec.warranty_entitlement_id,

Line 1481: FND_LOG.string(l_log_statement, l_full_name, 'After Update_Row');

1477: x_last_update_login => p_x_warranty_entl_rec.last_update_login
1478: );
1479:
1480: IF (l_log_statement >= l_log_current_level) THEN
1481: FND_LOG.string(l_log_statement, l_full_name, 'After Update_Row');
1482: END IF;
1483:
1484: -- for non-planner user and Approval Pending status update, launch the notification
1485: IF (NVL(p_user_role, 'X') = G_USER_NONPLANNER AND

Line 1488: FND_LOG.string(l_log_statement, l_full_name,

1484: -- for non-planner user and Approval Pending status update, launch the notification
1485: IF (NVL(p_user_role, 'X') = G_USER_NONPLANNER AND
1486: NVL(p_x_warranty_entl_rec.entitlement_status_code, 'X') = 'APPROVAL_PENDING') THEN
1487: IF (l_log_statement >= l_log_current_level) THEN
1488: FND_LOG.string(l_log_statement, l_full_name,
1489: 'before calling Launch_Entl_Notification with arguments: '||
1490: ' p_entitlement_id > '||p_x_warranty_entl_rec.warranty_entitlement_id);
1491: END IF;
1492:

Line 1502: FND_LOG.string(l_log_statement, l_full_name,

1498: x_item_key => l_item_key,
1499: x_return_status => l_return_status);
1500:
1501: IF (l_log_statement >= l_log_current_level) THEN
1502: FND_LOG.string(l_log_statement, l_full_name,
1503: 'after calling Launch_Entl_Notification, '||
1504: ' l_item_key > '||l_item_key||
1505: ', l_return_status'||l_return_status);
1506: END IF;

Line 1510: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

1506: END IF;
1507: END IF;
1508:
1509: IF (l_log_procedure >= l_log_current_level) THEN
1510: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
1511: END IF;
1512: END Update_Warranty_Entitlement;
1513: ------------------------------------------------------------------------------------
1514:

Line 1529: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

1525: --
1526:
1527: BEGIN
1528: IF (l_log_procedure >= l_log_current_level) THEN
1529: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
1530: END IF;
1531:
1532: -- check if the user is planner or not
1533: IF (NVL(p_user_role, 'X') <> G_USER_PLANNER) THEN

Line 1535: FND_LOG.string(l_log_statement, l_full_name, 'deletion permitted only to planner user');

1531:
1532: -- check if the user is planner or not
1533: IF (NVL(p_user_role, 'X') <> G_USER_PLANNER) THEN
1534: IF (l_log_statement >= l_log_current_level) THEN
1535: FND_LOG.string(l_log_statement, l_full_name, 'deletion permitted only to planner user');
1536: END IF;
1537: -- Warranty entitlement deletion is allowed only to the planner or the administrator.
1538: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_DEL_NOT_ALWD');
1539: FND_MSG_PUB.ADD;

Line 1544: FND_LOG.string(l_log_statement, l_full_name, 'Before Delete_Row');

1540: RETURN;
1541: END IF;
1542:
1543: IF (l_log_statement >= l_log_current_level) THEN
1544: FND_LOG.string(l_log_statement, l_full_name, 'Before Delete_Row');
1545: END IF;
1546:
1547: -- delete row
1548: AHL_WARRANTY_ENTITLEMENTS_PKG.Delete_Row(

Line 1553: FND_LOG.string(l_log_statement, l_full_name, 'After Delete_Row');

1549: x_warranty_entitlement_id => p_x_warranty_entl_rec.warranty_entitlement_id
1550: );
1551:
1552: IF (l_log_statement >= l_log_current_level) THEN
1553: FND_LOG.string(l_log_statement, l_full_name, 'After Delete_Row');
1554: END IF;
1555:
1556: IF (l_log_procedure >= l_log_current_level) THEN
1557: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

Line 1557: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

1553: FND_LOG.string(l_log_statement, l_full_name, 'After Delete_Row');
1554: END IF;
1555:
1556: IF (l_log_procedure >= l_log_current_level) THEN
1557: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
1558: END IF;
1559: END Delete_Warranty_Entitlement;
1560: ------------------------------------------------------------------------------------
1561:

Line 1594: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

1590: --
1591:
1592: BEGIN
1593: IF (l_log_procedure >= l_log_current_level) THEN
1594: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
1595: END IF;
1596:
1597: -- get the error message count till this point
1598: l_msg_count := FND_MSG_PUB.count_msg;

Line 1606: FND_LOG.string(l_log_statement, l_full_name,

1602: FETCH warranty_entl_csr INTO l_warranty_entl_rec;
1603: IF (warranty_entl_csr%NOTFOUND) THEN
1604: -- invalid entitlement id
1605: IF (l_log_statement >= l_log_current_level) THEN
1606: FND_LOG.string(l_log_statement, l_full_name,
1607: 'invalid entitlement id for approve '||p_x_warranty_entl_rec.warranty_entitlement_id);
1608: END IF;
1609: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_ENTL_ID_INVLD'); -- Warranty entitlement id ENTL_ID is invalid.
1610: FND_MESSAGE.Set_Token('ENTL_ID', p_x_warranty_entl_rec.warranty_entitlement_id);

Line 1619: FND_LOG.string(l_log_statement, l_full_name,

1615: -- check for the user
1616: IF (NVL(p_user_role, 'X') <> G_USER_PLANNER) THEN
1617: -- invalid user
1618: IF (l_log_statement >= l_log_current_level) THEN
1619: FND_LOG.string(l_log_statement, l_full_name,
1620: 'invalid user for approve '||p_user_role);
1621: END IF;
1622: -- Warranty entitlement approval is allowed only to the administrator.
1623: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_APPR_USER_INVLD');

Line 1631: FND_LOG.string(l_log_statement, l_full_name,

1627: -- check for the approval action
1628: IF (NVL(p_appr_action, 'X') NOT IN (G_APPR_ACCEPT, G_APPR_REJECT)) THEN
1629: -- invalid approval action
1630: IF (l_log_statement >= l_log_current_level) THEN
1631: FND_LOG.string(l_log_statement, l_full_name,
1632: 'invalid approval action '||p_appr_action);
1633: END IF;
1634: -- Warranty entitlement approval action can only be Accept or Reject.
1635: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_APPR_ACTION_INVLD');

Line 1643: FND_LOG.string(l_log_statement, l_full_name,

1639: -- check for the entitlement status
1640: IF (NVL(p_x_warranty_entl_rec.entitlement_status_code, 'X') <> 'APPROVAL_PENDING') THEN
1641: -- invalid entitlement status
1642: IF (l_log_statement >= l_log_current_level) THEN
1643: FND_LOG.string(l_log_statement, l_full_name,
1644: 'invalid entitlement status for approve '||p_x_warranty_entl_rec.entitlement_status_code);
1645: END IF;
1646: -- For approval operation, the warranty entitlement status can only be Approval Pending.
1647: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_APPR_STS_INVLD');

Line 1660: FND_LOG.string(l_log_statement, l_full_name,

1656: IF ((NVL(p_appr_action, 'X') = G_APPR_ACCEPT AND p_x_warranty_entl_rec.warranty_contract_id IS NULL) OR
1657: (NVL(p_appr_action, 'X') = G_APPR_REJECT AND l_warranty_entl_rec.old_warranty_contract_id IS NULL)) THEN
1658: -- use Not Applicable button instead
1659: IF (l_log_statement >= l_log_current_level) THEN
1660: FND_LOG.string(l_log_statement, l_full_name,
1661: 'Not Applicable button should be used instead');
1662: END IF;
1663: -- For dis-associating the warranty entitlement from a contract, use the Not Applicable action.
1664: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_APPR_USE_NA');

Line 1674: FND_LOG.string(l_log_statement, l_full_name, 'approval errored out, no need to validate contract id');

1670: -- 2) for Reject, validate the old contract
1671: -- NOTE: point 2 above is not needed, but retaining it for code consistency
1672: IF (l_msg_count < FND_MSG_PUB.count_msg) THEN
1673: IF (l_log_statement >= l_log_current_level) THEN
1674: FND_LOG.string(l_log_statement, l_full_name, 'approval errored out, no need to validate contract id');
1675: END IF;
1676: RETURN;
1677: END IF;
1678: IF (p_appr_action = G_APPR_ACCEPT) THEN

Line 1687: FND_LOG.string(l_log_statement, l_full_name,

1683: OPEN chk_war_cont_id_csr (l_contract_id);
1684: FETCH chk_war_cont_id_csr INTO l_dummy;
1685: IF (chk_war_cont_id_csr%NOTFOUND) THEN
1686: IF (l_log_statement >= l_log_current_level) THEN
1687: FND_LOG.string(l_log_statement, l_full_name,
1688: 'invalid contract id '||l_contract_id);
1689: END IF;
1690: -- Warranty contract id CONT_ID is invalid.
1691: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_CONT_ID_INVLD');

Line 1701: FND_LOG.string(l_log_statement, l_full_name, 'approval status transition errored out');

1697:
1698: -- if any errors occured, then don't proceed any further
1699: IF (l_msg_count < FND_MSG_PUB.count_msg) THEN
1700: IF (l_log_statement >= l_log_current_level) THEN
1701: FND_LOG.string(l_log_statement, l_full_name, 'approval status transition errored out');
1702: END IF;
1703: RETURN;
1704: END IF;
1705:

Line 1707: FND_LOG.string(l_log_statement, l_full_name, 'Before approval update');

1703: RETURN;
1704: END IF;
1705:
1706: IF (l_log_statement >= l_log_current_level) THEN
1707: FND_LOG.string(l_log_statement, l_full_name, 'Before approval update');
1708: END IF;
1709:
1710: -- update the warranty contract id, old contract id and the status
1711: UPDATE AHL_WARRANTY_ENTITLEMENTS SET

Line 1718: FND_LOG.string(l_log_statement, l_full_name, 'After approval update');

1714: entitlement_status_code = l_entl_status
1715: WHERE warranty_entitlement_id = p_x_warranty_entl_rec.warranty_entitlement_id;
1716:
1717: IF (l_log_statement >= l_log_current_level) THEN
1718: FND_LOG.string(l_log_statement, l_full_name, 'After approval update');
1719: END IF;
1720:
1721: IF (l_log_procedure >= l_log_current_level) THEN
1722: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

Line 1722: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

1718: FND_LOG.string(l_log_statement, l_full_name, 'After approval update');
1719: END IF;
1720:
1721: IF (l_log_procedure >= l_log_current_level) THEN
1722: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
1723: END IF;
1724: END Approve_Warranty_Entitlement;
1725: ------------------------------------------------------------------------------------
1726:

Line 1783: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');

1779: --
1780:
1781: BEGIN
1782: IF (l_log_procedure >= l_log_current_level) THEN
1783: FND_LOG.string(l_log_procedure, l_full_name || '.begin', 'Entering Procedure');
1784: END IF;
1785:
1786: -- Check: Non-planner user can create or update entitlement only in Approval Pending status
1787: IF (NVL(p_user_role, 'X') = G_USER_NONPLANNER AND

Line 1790: FND_LOG.string(l_log_statement, l_full_name,

1786: -- Check: Non-planner user can create or update entitlement only in Approval Pending status
1787: IF (NVL(p_user_role, 'X') = G_USER_NONPLANNER AND
1788: NVL(p_warranty_entl_rec.entitlement_status_code, 'X') <> 'APPROVAL_PENDING') THEN
1789: IF (l_log_statement >= l_log_current_level) THEN
1790: FND_LOG.string(l_log_statement, l_full_name,
1791: 'non-planner with incorrect status '||p_warranty_entl_rec.entitlement_status_code);
1792: END IF;
1793: -- Non-planner or non-administrator can create or update warranty entitlement only in Approval Pending status.
1794: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_NP_STS_INVLD');

Line 1802: FND_LOG.string(l_log_statement, l_full_name,

1798: -- Check: Not Applicable or Review status is allowed only for NULL contract id
1799: IF (NVL(p_warranty_entl_rec.entitlement_status_code, 'X') IN ('NOT_APPLICABLE', 'REVIEW') AND
1800: p_warranty_entl_rec.warranty_contract_id IS NOT NULL) THEN
1801: IF (l_log_statement >= l_log_current_level) THEN
1802: FND_LOG.string(l_log_statement, l_full_name,
1803: 'Not Applicable or Review status is allowed only for NULL contract id');
1804: END IF;
1805: -- Warranty entitlement can have status Not Applicable or Review only if it has no contract associated to it.
1806: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_NAR_STS_INVLD');

Line 1814: FND_LOG.string(l_log_statement, l_full_name,

1810: -- Check: Approved status is allowed only for non-NULL contract id
1811: IF (NVL(p_warranty_entl_rec.entitlement_status_code, 'X') = 'APPROVED' AND
1812: p_warranty_entl_rec.warranty_contract_id IS NULL) THEN
1813: IF (l_log_statement >= l_log_current_level) THEN
1814: FND_LOG.string(l_log_statement, l_full_name,
1815: 'Approved status is allowed only for non-NULL contract id');
1816: END IF;
1817: -- Warranty entitlement can have status Approved only if it has a valid contract associated to it.
1818: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_APRD_STS_INVLD');

Line 1830: FND_LOG.string(l_log_statement, l_full_name,

1826: OPEN chk_war_cont_id_csr (p_warranty_entl_rec.warranty_contract_id);
1827: FETCH chk_war_cont_id_csr INTO l_dummy;
1828: IF (chk_war_cont_id_csr%NOTFOUND) THEN
1829: IF (l_log_statement >= l_log_current_level) THEN
1830: FND_LOG.string(l_log_statement, l_full_name,
1831: 'invalid contract id '||p_warranty_entl_rec.warranty_contract_id);
1832: END IF;
1833: -- Warranty contract id CONT_ID is invalid.
1834: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_CONT_ID_INVLD');

Line 1847: FND_LOG.string(l_log_statement, l_full_name,

1843: OPEN chk_entl_sts_code_csr (p_warranty_entl_rec.entitlement_status_code);
1844: FETCH chk_entl_sts_code_csr INTO l_dummy;
1845: IF (chk_entl_sts_code_csr%NOTFOUND) THEN
1846: IF (l_log_statement >= l_log_current_level) THEN
1847: FND_LOG.string(l_log_statement, l_full_name,
1848: 'invalid entitlement status code '||p_warranty_entl_rec.entitlement_status_code);
1849: END IF;
1850: -- Warranty entitlement status code ENTL_STS is invalid.
1851: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_ENTL_STS_INVLD');

Line 1864: FND_LOG.string(l_log_statement, l_full_name,

1860: OPEN chk_claim_id_csr (p_warranty_entl_rec.warranty_claim_id);
1861: FETCH chk_claim_id_csr INTO l_dummy;
1862: IF (chk_claim_id_csr%NOTFOUND) THEN
1863: IF (l_log_statement >= l_log_current_level) THEN
1864: FND_LOG.string(l_log_statement, l_full_name,
1865: 'invalid claim id '||p_warranty_entl_rec.warranty_claim_id);
1866: END IF;
1867: -- Warranty entitlement claim id CLAIM_ID is invalid.
1868: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_CLAIM_ID_INVLD');

Line 1881: FND_LOG.string(l_log_statement, l_full_name,

1877: OPEN chk_incident_id_csr (p_warranty_entl_rec.sr_incident_id);
1878: FETCH chk_incident_id_csr INTO l_dummy;
1879: IF (chk_incident_id_csr%NOTFOUND) THEN
1880: IF (l_log_statement >= l_log_current_level) THEN
1881: FND_LOG.string(l_log_statement, l_full_name,
1882: 'invalid SR id '||p_warranty_entl_rec.sr_incident_id);
1883: END IF;
1884: -- The incident id 'INCIDENT_ID' is not valid.
1885: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_UMP_INVALID_INCIDENT_ID');

Line 1898: FND_LOG.string(l_log_statement, l_full_name,

1894: OPEN chk_visit_tsk_id_csr (p_warranty_entl_rec.visit_task_id);
1895: FETCH chk_visit_tsk_id_csr INTO l_dummy;
1896: IF (chk_visit_tsk_id_csr%NOTFOUND) THEN
1897: IF (l_log_statement >= l_log_current_level) THEN
1898: FND_LOG.string(l_log_statement, l_full_name,
1899: 'invalid visit task id '||p_warranty_entl_rec.visit_task_id);
1900: END IF;
1901: -- Visit task TASK_ID is invalid.
1902: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_LTP_TASK_ID_INVALID');

Line 1915: FND_LOG.string(l_log_statement, l_full_name,

1911: OPEN chk_workorder_id_csr (p_warranty_entl_rec.workorder_id);
1912: FETCH chk_workorder_id_csr INTO l_dummy;
1913: IF (chk_workorder_id_csr%NOTFOUND) THEN
1914: IF (l_log_statement >= l_log_current_level) THEN
1915: FND_LOG.string(l_log_statement, l_full_name,
1916: 'invalid workorder id '||p_warranty_entl_rec.workorder_id);
1917: END IF;
1918: -- Workorder id FIELD1 invalid.
1919: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_PRD_WORKORDER_ID_INVALID');

Line 1932: FND_LOG.string(l_log_statement, l_full_name,

1928: OPEN chk_osp_line_id_csr (p_warranty_entl_rec.osp_order_line_id);
1929: FETCH chk_osp_line_id_csr INTO l_dummy;
1930: IF (chk_osp_line_id_csr%NOTFOUND) THEN
1931: IF (l_log_statement >= l_log_current_level) THEN
1932: FND_LOG.string(l_log_statement, l_full_name,
1933: 'invalid OSP order line id '||p_warranty_entl_rec.osp_order_line_id);
1934: END IF;
1935: -- OSP order line id OLINE_ID is invalid.
1936: FND_MESSAGE.Set_Name(G_APP_NAME, 'AHL_WARRANTY_OLINE_ID_INVLD');

Line 1945: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');

1941: END IF;
1942: -- ***************************************
1943:
1944: IF (l_log_procedure >= l_log_current_level) THEN
1945: FND_LOG.string(l_log_procedure, l_full_name || '.end', 'Exiting Procedure');
1946: END IF;
1947: END Validate_Warranty_Entitlement;
1948: ------------------------------------------------------------------------------------
1949: