DBA Data[Home] [Help]

APPS.ENG_VALIDATE_REVISED_ITEM dependencies on FND_PROFILE

Line 2068: (FND_PROFILE.VALUE('ENG:ECO_REVISED_ITEM_REVISION'));

2064: l_Token_Tbl(1).Token_name := 'REVISED_ITEM_NAME';
2065: l_Token_Tbl(1).Token_Value := p_revised_item_Rec.revised_item_name;
2066:
2067: BOM_Globals.Set_Require_Item_Rev
2068: (FND_PROFILE.VALUE('ENG:ECO_REVISED_ITEM_REVISION'));
2069:
2070: IF (Bom_globals.Get_Caller_Type = BOM_GLOBALS.G_MASS_CHANGE) THEN
2071: Null;
2072: ELSE

Line 3514: l_allow_expense_to_asset := fnd_profile.value

3510: ) ;
3511:
3512: ELSE
3513:
3514: l_allow_expense_to_asset := fnd_profile.value
3515: ('INV:EXPENSE_TO_ASSET_TRANSFER');
3516:
3517:
3518: Get_SubInv_Flag

Line 6293: l_profile_exist := FND_PROFILE.DEFINED ( 'EGO_ITEM_RESTRICT_INV_ACTIONS' );

6289: END IF;
6290: --Start of changes Bug no:3034642
6291:
6292: x_disable_revision :=2;
6293: l_profile_exist := FND_PROFILE.DEFINED ( 'EGO_ITEM_RESTRICT_INV_ACTIONS' );
6294: if (l_profile_exist = TRUE) then
6295: FND_PROFILE.GET ( 'EGO_ITEM_RESTRICT_INV_ACTIONS', l_profile_val );
6296: if ( l_profile_val = '2') then
6297: FOR sc IN c_get_default_life(p_rev_item_unexp_rec.Revised_Item_Id , p_rev_item_unexp_rec.Organization_Id)

Line 6295: FND_PROFILE.GET ( 'EGO_ITEM_RESTRICT_INV_ACTIONS', l_profile_val );

6291:
6292: x_disable_revision :=2;
6293: l_profile_exist := FND_PROFILE.DEFINED ( 'EGO_ITEM_RESTRICT_INV_ACTIONS' );
6294: if (l_profile_exist = TRUE) then
6295: FND_PROFILE.GET ( 'EGO_ITEM_RESTRICT_INV_ACTIONS', l_profile_val );
6296: if ( l_profile_val = '2') then
6297: FOR sc IN c_get_default_life(p_rev_item_unexp_rec.Revised_Item_Id , p_rev_item_unexp_rec.Organization_Id)
6298: LOOP
6299: l_Old_Phase_Id := sc.current_phase_id;

Line 6560: IF (NVL(fnd_profile.value('ENG:ENG_ITEM_ECN_ACCESS'), 1) = 2)

6556: );
6557: ***********************************/
6558:
6559: ---Check if user has access to Engineering item or not bug:4942705
6560: IF (NVL(fnd_profile.value('ENG:ENG_ITEM_ECN_ACCESS'), 1) = 2)
6561: THEN
6562: FOR revised_item IN c_RevItemType
6563: LOOP
6564: IF revised_item.eng_item_flag = 'Y' THEN

Line 6673: IF NVL(fnd_profile.value('ENG:STANDARD_ITEM_ECN_ACCESS'), 1) = 1

6669:
6670: --
6671: -- Get respective profile values
6672: --
6673: IF NVL(fnd_profile.value('ENG:STANDARD_ITEM_ECN_ACCESS'), 1) = 1
6674: THEN
6675: BOM_Globals.Set_STD_Item_Access
6676: ( p_std_item_access => 4);
6677: ELSE

Line 6683: IF fnd_profile.value('ENG:MODEL_ITEM_ECN_ACCESS') = '1'

6679: BOM_Globals.Set_STD_Item_Access
6680: (p_std_item_access => NULL);
6681: END IF;
6682:
6683: IF fnd_profile.value('ENG:MODEL_ITEM_ECN_ACCESS') = '1'
6684: THEN
6685: BOM_Globals.Set_MDL_Item_Access
6686: ( p_mdl_item_access => 1);
6687: BOM_Globals.Set_OC_Item_Access

Line 6696: IF fnd_profile.value('ENG:PLANNING_ITEM_ECN_ACCESS') = '1'

6692: BOM_Globals.Set_OC_Item_Access
6693: ( p_oc_item_access => NULL);
6694: END IF;
6695:
6696: IF fnd_profile.value('ENG:PLANNING_ITEM_ECN_ACCESS') = '1'
6697: THEN
6698: BOM_Globals.Set_PLN_Item_Access
6699: ( p_pln_item_access => 3);
6700: ELSE

Line 7166: BOM_Globals.Set_Require_Item_Rev(FND_PROFILE.VALUE('ENG:ECO_REVISED_ITEM_REVISION'));

7162: BOM_Globals.Set_Unit_Controlled_Item(
7163: p_inventory_item_id => p_revised_item_id
7164: , p_organization_id => p_organization_id
7165: );
7166: BOM_Globals.Set_Require_Item_Rev(FND_PROFILE.VALUE('ENG:ECO_REVISED_ITEM_REVISION'));
7167: Eng_Globals.Set_Bo_Identifier( p_bo_identifier => p_bo_identifier);
7168: Eng_Globals.Set_Org_Id( p_org_id => p_organization_id);
7169:
7170: -- Bug 12310735. If alternate designator is Primary, set it to NULL.