DBA Data[Home] [Help]

APPS.AMS_UTILITY_PVT dependencies on FND_LOG

Line 102: --IF( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

98: IS
99: l_pLog BOOLEAN;
100:
101: BEGIN
102: --IF( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
103:
104: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
105: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
106: FND_LOG.STRING(p_log_level, p_module_name, p_text);

Line 104: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);

100:
101: BEGIN
102: --IF( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
103:
104: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
105: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
106: FND_LOG.STRING(p_log_level, p_module_name, p_text);
107: END IF;
108: END debug_message;

Line 105: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

101: BEGIN
102: --IF( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
103:
104: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
105: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
106: FND_LOG.STRING(p_log_level, p_module_name, p_text);
107: END IF;
108: END debug_message;
109:

Line 106: FND_LOG.STRING(p_log_level, p_module_name, p_text);

102: --IF( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
103:
104: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
105: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
106: FND_LOG.STRING(p_log_level, p_module_name, p_text);
107: END IF;
108: END debug_message;
109:
110:

Line 125: -- FND_LOG.MESSAGE(..., FALSE); -- Log message

121: -- displayed to the user later.
122: -- Example usage:
123: -- FND_MESSAGE.SET_NAME(...); -- Set message
124: -- FND_MESSAGE.SET_TOKEN(...); -- Set token in message
125: -- FND_LOG.MESSAGE(..., FALSE); -- Log message
126: -- FND_MESSAGE.ERROR; -- Display message
127: --
128: -- HISTORY
129: -- 01-Oct-2003 huili Create.

Line 141: --IF ( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

137:
138: l_pLog BOOLEAN;
139:
140: BEGIN
141: --IF ( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
142:
143: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
144:
145: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

Line 143: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);

139:
140: BEGIN
141: --IF ( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
142:
143: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
144:
145: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
146: IF p_RCS_ID IS NOT NULL THEN
147: FND_MESSAGE.SET_TOKEN(G_RCS_ID, p_RCS_ID);

Line 145: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN

141: --IF ( p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
142:
143: l_pLog := (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
144:
145: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
146: IF p_RCS_ID IS NOT NULL THEN
147: FND_MESSAGE.SET_TOKEN(G_RCS_ID, p_RCS_ID);
148: END IF;
149: FND_LOG.MESSAGE(p_log_level, p_module_name, p_pop_message);

Line 149: FND_LOG.MESSAGE(p_log_level, p_module_name, p_pop_message);

145: IF (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL) THEN
146: IF p_RCS_ID IS NOT NULL THEN
147: FND_MESSAGE.SET_TOKEN(G_RCS_ID, p_RCS_ID);
148: END IF;
149: FND_LOG.MESSAGE(p_log_level, p_module_name, p_pop_message);
150: END IF;
151: END log_message;
152:
153: --======================================================================

Line 167: RETURN (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);

163: FUNCTION logging_enabled (p_log_level IN NUMBER)
164: RETURN BOOLEAN
165: IS
166: BEGIN
167: RETURN (p_log_level >= FND_LOG.G_CURRENT_RUNTIME_LEVEL);
168: END;
169:
170:
171: