DBA Data[Home] [Help]

APPS.PER_RI_CONFIG_UTILITIES dependencies on PER_RI_CONFIG_TECH_SUMMARY

Line 168: per_ri_config_tech_summary.int_hrms_setup_tab);

164: ,retcode out nocopy number
165: ,p_country_tab in per_ri_config_datapump_entity.country_tab
166: ,p_technical_summary_mode in boolean default FALSE
167: ,p_int_hrms_setup_tab in out nocopy
168: per_ri_config_tech_summary.int_hrms_setup_tab);
169:
170: PROCEDURE create_security_profile_assign(
171: p_security_profile_tab in per_ri_config_fnd_hr_entity.security_profile_tab);
172:

Line 202: ,p_hrms_misc_resp_tab in out nocopy per_ri_config_tech_summary.hrms_misc_resp_tab);

198:
199: PROCEDURE assign_misc_responsibility
200: (p_configuration_code in varchar2
201: ,p_technical_summary_mode in boolean default FALSE
202: ,p_hrms_misc_resp_tab in out nocopy per_ri_config_tech_summary.hrms_misc_resp_tab);
203:
204: FUNCTION return_config_entity_name(entity_name in varchar2)
205: RETURN varchar2;
206:

Line 221: per_ri_config_tech_summary.valueset_tab);

217: ,p_segment_name in varchar2
218: ,p_segment_number in varchar2
219: ,p_fed_seg_attribute in varchar2 default 'N'
220: ,p_valueset_tab in out nocopy
221: per_ri_config_tech_summary.valueset_tab);
222: PROCEDURE create_responsibility
223: (p_app_short_name in fnd_application.application_short_name%type
224: ,p_resp_key in fnd_responsibility_vl.responsibility_name%type
225: ,p_responsibility_id in fnd_responsibility.responsibility_id%type

Line 245: ,p_hrms_resp_main_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab

241: (p_configuration_code in varchar2
242: ,p_security_profile_tab in per_ri_config_fnd_hr_entity.security_profile_tab
243: ,p_int_bg_resp_tab in per_ri_config_fnd_hr_entity.int_bg_resp_tab
244: ,p_technical_summary_mode in boolean default FALSE
245: ,p_hrms_resp_main_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab
246: ,p_more_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab
247: ,p_more_int_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab);
248:
249: PROCEDURE create_resp_and_profile

Line 246: ,p_more_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab

242: ,p_security_profile_tab in per_ri_config_fnd_hr_entity.security_profile_tab
243: ,p_int_bg_resp_tab in per_ri_config_fnd_hr_entity.int_bg_resp_tab
244: ,p_technical_summary_mode in boolean default FALSE
245: ,p_hrms_resp_main_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab
246: ,p_more_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab
247: ,p_more_int_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab);
248:
249: PROCEDURE create_resp_and_profile
250: (p_configuration_code in varchar2

Line 247: ,p_more_int_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab);

243: ,p_int_bg_resp_tab in per_ri_config_fnd_hr_entity.int_bg_resp_tab
244: ,p_technical_summary_mode in boolean default FALSE
245: ,p_hrms_resp_main_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab
246: ,p_more_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab
247: ,p_more_int_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab);
248:
249: PROCEDURE create_resp_and_profile
250: (p_configuration_code in varchar2
251: ,p_security_profile_name in varchar2

Line 254: ,p_bg_sg_ut_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab

250: (p_configuration_code in varchar2
251: ,p_security_profile_name in varchar2
252: ,p_responsibility_key in varchar2
253: ,p_technical_summary_mode in boolean default FALSE
254: ,p_bg_sg_ut_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab
255: ,p_hrms_resp_one_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab);
256:
257: FUNCTION get_responsibility_name (p_responsibility_key in varchar2)
258: RETURN varchar2;

Line 255: ,p_hrms_resp_one_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab);

251: ,p_security_profile_name in varchar2
252: ,p_responsibility_key in varchar2
253: ,p_technical_summary_mode in boolean default FALSE
254: ,p_bg_sg_ut_profile_resp_tab in out nocopy per_ri_config_tech_summary.profile_resp_tab
255: ,p_hrms_resp_one_tab in out nocopy per_ri_config_tech_summary.hrms_resp_tab);
256:
257: FUNCTION get_responsibility_name (p_responsibility_key in varchar2)
258: RETURN varchar2;
259: