DBA Data[Home] [Help]

APPS.POR_RCV_ORD_SV dependencies on FND_MESSAGE

Line 1319: x_message := fnd_message.get;

1315: mo_global.set_policy_context(p_access_mode => 'S',
1316: p_org_id => x_user_org_id);
1317: end if;
1318: if (x_caller = 'WP4' OR x_caller ='WP4_CONFIRM') then
1319: x_message := fnd_message.get;
1320: if (x_message = '') THEN
1321: ERROR_STACK.PUSHMESSAGE(x_message,'ICX');
1322: asn_debug.put_line(x_message);
1323: ELSE

Line 1744: fnd_message.set_name('FND', 'TM-TIMEOUT');

1740: asn_debug.put_line(x_progress);
1741:
1742: if rc = 1 then
1743: if (por_rcv_ord_SV.check_group_id(X_group_id)) then
1744: fnd_message.set_name('FND', 'TM-TIMEOUT');
1745: x_str := fnd_message.get;
1746: fnd_message.clear;
1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');

Line 1745: x_str := fnd_message.get;

1741:
1742: if rc = 1 then
1743: if (por_rcv_ord_SV.check_group_id(X_group_id)) then
1744: fnd_message.set_name('FND', 'TM-TIMEOUT');
1745: x_str := fnd_message.get;
1746: fnd_message.clear;
1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');

Line 1746: fnd_message.clear;

1742: if rc = 1 then
1743: if (por_rcv_ord_SV.check_group_id(X_group_id)) then
1744: fnd_message.set_name('FND', 'TM-TIMEOUT');
1745: x_str := fnd_message.get;
1746: fnd_message.clear;
1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1750: fnd_message.set_token('REQUEST', X_group_id);

Line 1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');

1744: fnd_message.set_name('FND', 'TM-TIMEOUT');
1745: x_str := fnd_message.get;
1746: fnd_message.clear;
1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1750: fnd_message.set_token('REQUEST', X_group_id);
1751: fnd_message.set_token('REASON', x_str);
1752:

Line 1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');

1745: x_str := fnd_message.get;
1746: fnd_message.clear;
1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1750: fnd_message.set_token('REQUEST', X_group_id);
1751: fnd_message.set_token('REASON', x_str);
1752:
1753: htp.nl;

Line 1750: fnd_message.set_token('REQUEST', X_group_id);

1746: fnd_message.clear;
1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1750: fnd_message.set_token('REQUEST', X_group_id);
1751: fnd_message.set_token('REASON', x_str);
1752:
1753: htp.nl;
1754: x_output_message := fnd_message.get;

Line 1751: fnd_message.set_token('REASON', x_str);

1747:
1748: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1749: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1750: fnd_message.set_token('REQUEST', X_group_id);
1751: fnd_message.set_token('REASON', x_str);
1752:
1753: htp.nl;
1754: x_output_message := fnd_message.get;
1755:

Line 1754: x_output_message := fnd_message.get;

1750: fnd_message.set_token('REQUEST', X_group_id);
1751: fnd_message.set_token('REASON', x_str);
1752:
1753: htp.nl;
1754: x_output_message := fnd_message.get;
1755:
1756: if (X_caller <> 'WP4'OR x_caller <> 'WP4_CONFIRM') then
1757: htp.teletype(x_output_message);
1758: htp.nl;

Line 1769: fnd_message.set_name('FND', 'TM-SVC LOCK HANDLE FAILED');

1765: elsif rc = 2 then
1766: IF (por_rcv_ord_SV.check_group_id(X_group_id)) THEN
1767:
1768:
1769: fnd_message.set_name('FND', 'TM-SVC LOCK HANDLE FAILED');
1770: x_str := fnd_message.get;
1771:
1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1773:

Line 1770: x_str := fnd_message.get;

1766: IF (por_rcv_ord_SV.check_group_id(X_group_id)) THEN
1767:
1768:
1769: fnd_message.set_name('FND', 'TM-SVC LOCK HANDLE FAILED');
1770: x_str := fnd_message.get;
1771:
1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1773:
1774: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');

Line 1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');

1768:
1769: fnd_message.set_name('FND', 'TM-SVC LOCK HANDLE FAILED');
1770: x_str := fnd_message.get;
1771:
1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1773:
1774: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1775: fnd_message.set_token('REQUEST', X_group_id);
1776: fnd_message.set_token('REASON', x_str);

Line 1774: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');

1770: x_str := fnd_message.get;
1771:
1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1773:
1774: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1775: fnd_message.set_token('REQUEST', X_group_id);
1776: fnd_message.set_token('REASON', x_str);
1777:
1778:

Line 1775: fnd_message.set_token('REQUEST', X_group_id);

1771:
1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1773:
1774: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1775: fnd_message.set_token('REQUEST', X_group_id);
1776: fnd_message.set_token('REASON', x_str);
1777:
1778:
1779: x_output_message := fnd_message.get;

Line 1776: fnd_message.set_token('REASON', x_str);

1772: FND_MESSAGE.set_name('FND','CONC-Error running standalone');
1773:
1774: fnd_message.set_token('PROGRAM', 'Receiving Transaction Manager - RCVOLTM');
1775: fnd_message.set_token('REQUEST', X_group_id);
1776: fnd_message.set_token('REASON', x_str);
1777:
1778:
1779: x_output_message := fnd_message.get;
1780: ERROR_STACK.PUSHMESSAGE( x_output_message, 'ICX');

Line 1779: x_output_message := fnd_message.get;

1775: fnd_message.set_token('REQUEST', X_group_id);
1776: fnd_message.set_token('REASON', x_str);
1777:
1778:
1779: x_output_message := fnd_message.get;
1780: ERROR_STACK.PUSHMESSAGE( x_output_message, 'ICX');
1781: asn_debug.put_line('return 2, msg=' || x_output_message);
1782: end if;
1783: delete_rows := TRUE;

Line 1825: fnd_message.clear;

1821: */
1822: if (rc1 = 0 and outcome IN ('WARNING', 'ERROR')) then
1823: rc := 4;
1824: elsif rc=3 then
1825: fnd_message.clear;
1826: fnd_message.set_name('ICX','ICX_POR_RCV_TXN_MGR_DOWN_ERROR');
1827: x_output_message := fnd_message.get;
1828: ERROR_STACK.PUSHMESSAGE(x_output_message,'ICX');
1829: end if;

Line 1826: fnd_message.set_name('ICX','ICX_POR_RCV_TXN_MGR_DOWN_ERROR');

1822: if (rc1 = 0 and outcome IN ('WARNING', 'ERROR')) then
1823: rc := 4;
1824: elsif rc=3 then
1825: fnd_message.clear;
1826: fnd_message.set_name('ICX','ICX_POR_RCV_TXN_MGR_DOWN_ERROR');
1827: x_output_message := fnd_message.get;
1828: ERROR_STACK.PUSHMESSAGE(x_output_message,'ICX');
1829: end if;
1830:

Line 1827: x_output_message := fnd_message.get;

1823: rc := 4;
1824: elsif rc=3 then
1825: fnd_message.clear;
1826: fnd_message.set_name('ICX','ICX_POR_RCV_TXN_MGR_DOWN_ERROR');
1827: x_output_message := fnd_message.get;
1828: ERROR_STACK.PUSHMESSAGE(x_output_message,'ICX');
1829: end if;
1830:
1831: END IF;