DBA Data[Home] [Help]

APPS.AHL_ENIGMA_IPC_PROCS_PVT dependencies on AHL_MC_POS_STACK

Line 708: -- 3) AHL_MC_POS_STACK

704:
705: -- Following three object types have been defined in the DB. For details, please refer their XDFs.
706: -- 1) AHL_MC_POS_REF
707: -- 2) AHL_MC_POS_DETAIL
708: -- 3) AHL_MC_POS_STACK
709:
710: l_mc_header_rec AHL_MC_MasterConfig_PVT.Header_Rec_Type DEFAULT p_mc_header_rec;
711: l_nodes_tbl AHL_MC_Node_PVT.Node_Tbl_Type DEFAULT p_nodes_tbl;
712:

Line 713: l_mc_pos_stack AHL_MC_POS_STACK := AHL_MC_POS_STACK(NULL, NULL, NULL);

709:
710: l_mc_header_rec AHL_MC_MasterConfig_PVT.Header_Rec_Type DEFAULT p_mc_header_rec;
711: l_nodes_tbl AHL_MC_Node_PVT.Node_Tbl_Type DEFAULT p_nodes_tbl;
712:
713: l_mc_pos_stack AHL_MC_POS_STACK := AHL_MC_POS_STACK(NULL, NULL, NULL);
714: l_mc_pos_ref AHL_MC_POS_REF := AHL_MC_POS_REF(NULL, NULL);
715: l_stack_data AHL_MC_POS_REF := NULL;
716:
717: l_dummy VARCHAR2(1);

Line 944: -- Position stack AHL_MC_POS_STACK object has exceeded its max_size. Please increase it to an appropriate value. (new message)

940: l_mc_pos_ref.put(l_nodes_tbl(i).position_ref_code, l_nodes_tbl(i).relationship_id);
941: IF (NOT l_mc_pos_stack.over_flow) THEN
942: l_mc_pos_stack.push(l_mc_pos_ref);
943: ELSE
944: -- Position stack AHL_MC_POS_STACK object has exceeded its max_size. Please increase it to an appropriate value. (new message)
945: FND_MESSAGE.Set_Name('AHL', 'AHL_MC_ENIGMA_STACK_OVRFLW');
946: FND_MSG_PUB.ADD;
947: RAISE FND_API.G_EXC_UNEXPECTED_ERROR;
948: END IF;