DBA Data[Home] [Help]

APPS.FND_OAM_DSCRAM_DIAG_PKG dependencies on FND_NUMBER

Line 429: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);

425: IF l_valid_value_flag IS NULL OR l_valid_value_flag <> FND_API.G_TRUE THEN
426: fnd_oam_debug.log(6, l_ctxt, 'Valid value flag of C2 Sum is incorrect: '||l_valid_value_flag);
427: RETURN FALSE;
428: END IF;
429: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);
430: END IF;
431: EXCEPTION
432: WHEN OTHERS THEN
433: fnd_oam_debug.log(6, l_ctxt, 'Failed to query arg value for C2 sum: (Code('||SQLCODE||'), Message("'||SQLERRM||'"))');

Line 459: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);

455: IF l_valid_value_flag IS NULL OR l_valid_value_flag <> FND_API.G_TRUE THEN
456: fnd_oam_debug.log(6, l_ctxt, 'Valid value flag of C3 Bad Count is incorrect: '||l_valid_value_flag);
457: RETURN FALSE;
458: END IF;
459: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);
460: END IF;
461: EXCEPTION
462: WHEN OTHERS THEN
463: fnd_oam_debug.log(6, l_ctxt, 'Failed to query arg value for C3 bad count: (Code('||SQLCODE||'), Message("'||SQLERRM||'"))');

Line 490: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);

486: IF l_valid_value_flag IS NULL OR l_valid_value_flag <> FND_API.G_TRUE THEN
487: fnd_oam_debug.log(6, l_ctxt, 'Valid value flag of C4 Bad Count is incorrect: '||l_valid_value_flag);
488: RETURN FALSE;
489: END IF;
490: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);
491: END IF;
492: EXCEPTION
493: WHEN OTHERS THEN
494: fnd_oam_debug.log(6, l_ctxt, 'Failed to query arg value for C4 bad count: (Code('||SQLCODE||'), Message("'||SQLERRM||'"))');

Line 3115: l_c2_final_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);

3111: IF l_valid_value_flag IS NULL OR l_valid_value_flag <> FND_API.G_TRUE THEN
3112: fnd_oam_debug.log(6, l_ctxt, 'Valid value flag of final C2 Sum for dml is incorrect: '||l_valid_value_flag);
3113: RAISE VALIDATE_FAILED;
3114: END IF;
3115: l_c2_final_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);
3116: IF l_c2_final_sum IS NULL OR l_c2_final_sum <> p_test_tab_num_rows THEN
3117: fnd_oam_debug.log(6, l_ctxt, 'Final C2 Sum('||l_c2_final_sum||') not equal to target value('||p_test_tab_num_rows||')');
3118: RAISE VALIDATE_FAILED;
3119: END IF;

Line 4432: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);

4428: IF l_valid_value_flag IS NULL OR l_valid_value_flag <> FND_API.G_TRUE THEN
4429: fnd_oam_debug.log(6, l_ctxt, 'Valid value flag of run C2 intermediate sum is incorrect: '||l_valid_value_flag);
4430: RAISE VALIDATE_FAILED;
4431: END IF;
4432: l_c2_sum := FND_NUMBER.CANONICAL_TO_NUMBER(l_canonical_value);
4433: EXCEPTION
4434: WHEN VALIDATE_FAILED THEN
4435: RAISE;
4436: WHEN OTHERS THEN