[Home] [Help] [Dependency Information]
Object Name: | IEU_UWQ_RTNODE_BIND_VALS |
---|---|
Object Type: | TABLE |
Owner: | IEU |
FND Design Data: | IEU.IEU_UWQ_RTNODE_BIND_VALS |
Subobject Name: | |
Status: | VALID |
Oracle Corporation does not support access to Oracle
applications data using this object, except from standard Oracle Applications programs.
Tablespace: | APPS_TS_TX_DATA |
---|---|
PCT Free: | 10 |
PCT Used: |
Index | Type | Uniqueness | Tablespace | Column |
---|---|---|---|---|
IEU_UWQ_RTNODE_BIND_VALS_U1 | NORMAL | UNIQUE | APPS_TS_TX_IDX |
RESOURCE_ID
NODE_ID BIND_VAR_NAME |
IEU_UWQ_RTNODE_BIND_VALS_U2 | NORMAL | UNIQUE | APPS_TS_TX_IDX | RTNODE_BIND_VAR_ID |
IEU_UWQ_RTNODE_BIND_VALS_N1 | NORMAL | NONUNIQUE | APPS_TS_TX_IDX | SEL_RT_NODE_ID |
IEU_UWQ_RTNODE_BIND_VALS_N2 | NORMAL | NONUNIQUE | APPS_TS_TX_IDX |
RESOURCE_ID
NODE_ID NOT_VALID_FLAG |
Name | Datatype | Length | Mandatory | Comments |
---|---|---|---|---|
RTNODE_BIND_VAR_ID | NUMBER | (15) | Yes | Uniquely identifies the Bind variable in the selector node row. |
OBJECT_VERSION_NUMBER | NUMBER | Yes | Standard column used by HTML utilities. | |
CREATED_BY | NUMBER | (15) | Yes | Standard WHO columns. |
CREATION_DATE | DATE | Yes | Standard WHO columns. | |
LAST_UPDATED_BY | NUMBER | (15) | Yes | Standard WHO columns. |
LAST_UPDATE_DATE | DATE | Yes | Standard WHO columns. | |
LAST_UPDATE_LOGIN | NUMBER | (15) | Standard WHO columns. | |
SECURITY_GROUP_ID | NUMBER | Used in hosted environments | ||
SEL_RT_NODE_ID | NUMBER | (15) | Yes | Uniquely identifies selector node row. |
RESOURCE_ID | NUMBER | (15) | Yes | Identifies JTF resource ID of the agent. |
NODE_ID | NUMBER | (10) | Yes | Node ID. |
BIND_VAR_NAME | VARCHAR2 | (32) | Yes | Name of the Bind Variable for the node |
BIND_VAR_VALUE | VARCHAR2 | (1990) | Name of the Bind Variable for the node | |
BIND_VAR_DATATYPE | VARCHAR2 | (240) | Datatype of the Bind Variable for the node | |
NOT_VALID_FLAG | VARCHAR2 | (1) | Indicates if row is valid (or not). |
Cut, paste (and edit) the following text to query this object:
SELECT RTNODE_BIND_VAR_ID
, OBJECT_VERSION_NUMBER
, CREATED_BY
, CREATION_DATE
, LAST_UPDATED_BY
, LAST_UPDATE_DATE
, LAST_UPDATE_LOGIN
, SECURITY_GROUP_ID
, SEL_RT_NODE_ID
, RESOURCE_ID
, NODE_ID
, BIND_VAR_NAME
, BIND_VAR_VALUE
, BIND_VAR_DATATYPE
, NOT_VALID_FLAG
FROM IEU.IEU_UWQ_RTNODE_BIND_VALS;
IEU.IEU_UWQ_RTNODE_BIND_VALS does not reference any database object
IEU.IEU_UWQ_RTNODE_BIND_VALS is referenced by following:
|
|
|