DBA Data[Home] [Help]

APPS.PON_CLO_RENUMBER_PKG dependencies on PON_CLO_RENUMBER_PKG

Line 1: PACKAGE BODY pon_clo_renumber_pkg AS

1: PACKAGE BODY pon_clo_renumber_pkg AS
2: /* $Header: PONCLORNB.pls 120.27.12020000.2 2013/02/09 08:50:06 hvutukur ship $ */
3:
4: -----------------------------------------------------------------
5: FUNCTION sort_table(LineArray PO_TBL_VARCHAR100)

Line 468: next_clin := pon_clo_renumber_pkg.next_clin_num(tbl);

464: || ' order by line_num_display';
465: END IF;
466: EXECUTE IMMEDIATE line_num_tbl_qry BULK COLLECT INTO tbl;
467:
468: next_clin := pon_clo_renumber_pkg.next_clin_num(tbl);
469: RETURN next_clin;
470: END;
471:
472: FUNCTION ELIN_TO_DECIMAL(linNum VARCHAR2) RETURN NUMBER

Line 539: (SELECT pon_clo_renumber_pkg.ELIN_TO_DECIMAL(SubStr(line_num_display,exhibit_len+1,4-exhibit_len)) elin_decimal

535:
536: SELECT Nvl(Max(ROWNUM),0)+1
537: INTO lineNumber
538: FROM
539: (SELECT pon_clo_renumber_pkg.ELIN_TO_DECIMAL(SubStr(line_num_display,exhibit_len+1,4-exhibit_len)) elin_decimal
540: FROM
541: pon_auction_item_prices_all where auction_header_id = p_Document_ID
542: and exhibit_number = p_exhibit_number AND line_num_display IS NOT null order by elin_decimal)
543: WHERE ELIN_DECIMAL=rownum;

Line 592: line_num_tbl_qry := 'SELECT Nvl(Max(ROWNUM),0)+1 FROM (SELECT pon_clo_renumber_pkg.ELIN_TO_DECIMAL(SubStr(line_num_display,'

588: exhibit_len:=Length(p_exhibit_number);
589:
590: setProductContext(p_product_code,lines_tbl_name,doc_id_col,lineid_col,exhibit_col);
591:
592: line_num_tbl_qry := 'SELECT Nvl(Max(ROWNUM),0)+1 FROM (SELECT pon_clo_renumber_pkg.ELIN_TO_DECIMAL(SubStr(line_num_display,'
593: || exhibit_len||'+1,4-'||exhibit_len||')) elin_decimal FROM '
594: || lines_tbl_name
595: || ' where ' || doc_id_col || ' = ' || p_Document_ID
596: || ' and '||exhibit_col||' ='''||p_exhibit_number||''''

Line 664: next_clin := pon_clo_renumber_pkg.next_clin_num(union_table);

660: EXECUTE IMMEDIATE line_num_tbl_qry BULK COLLECT INTO tbl;
661:
662: union_table := tbl multiset UNION new_lines;
663:
664: next_clin := pon_clo_renumber_pkg.next_clin_num(union_table);
665: RETURN next_clin;
666: END;
667:
668:

Line 973: l_pkg_name CONSTANT VARCHAR2(30) := 'PON_CLO_RENUMBER_PKG';

969: slins po_tbl_varchar100 := po_tbl_varchar100();
970: newslin VARCHAR2(6);
971:
972: l_fnd_debug CONSTANT VARCHAR2(1) := NVL(FND_PROFILE.VALUE('AFLOG_ENABLED'),'N');
973: l_pkg_name CONSTANT VARCHAR2(30) := 'PON_CLO_RENUMBER_PKG';
974: l_module_prefix CONSTANT VARCHAR2(50) := 'pon.plsql.' || l_pkg_name || '.';
975: l_module CONSTANT VARCHAR2(32) := 'GetNextSlinNumber';
976: l_message VARCHAR2(1000);
977:

Line 1010: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);

1006:
1007: IF(newslin <> slins(i)) THEN
1008: --Dbms_Output.put_line(' got hole ' || newslin);
1009: /*IF(InStr(newslin,'I')<>0 OR InStr(newslin,'O') <> 0) THEN
1010: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);
1011: CONTINUE;
1012: END IF;*/
1013: RETURN newslin;
1014: END IF;

Line 1016: newslin := pon_clo_renumber_pkg.INCREMENT_INFO_SLIN_NUMBER(newslin);

1012: END IF;*/
1013: RETURN newslin;
1014: END IF;
1015:
1016: newslin := pon_clo_renumber_pkg.INCREMENT_INFO_SLIN_NUMBER(newslin);
1017: END LOOP;
1018:
1019: RETURN newslin;
1020: -- l_nextNum := pon_clo_renumber_pkg.testIncrementInfoSlinNum(l_infoSlinNum);

Line 1020: -- l_nextNum := pon_clo_renumber_pkg.testIncrementInfoSlinNum(l_infoSlinNum);

1016: newslin := pon_clo_renumber_pkg.INCREMENT_INFO_SLIN_NUMBER(newslin);
1017: END LOOP;
1018:
1019: RETURN newslin;
1020: -- l_nextNum := pon_clo_renumber_pkg.testIncrementInfoSlinNum(l_infoSlinNum);
1021: -- Dbms_Output.put_line(l_nextNum);
1022:
1023: EXCEPTION
1024: WHEN OTHERS THEN

Line 1058: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);

1054:
1055: IF(newslin <> slins(i)) THEN
1056: --Dbms_Output.put_line(' got hole ' || newslin);
1057: /*IF(InStr(newslin,'I')<>0 OR InStr(newslin,'O') <> 0) THEN
1058: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);
1059: CONTINUE;
1060: END IF;*/
1061: RETURN newslin;
1062: END IF;

Line 1064: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);

1060: END IF;*/
1061: RETURN newslin;
1062: END IF;
1063:
1064: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);
1065: END LOOP;
1066:
1067: RETURN newslin;
1068: -- l_nextNum := pon_clo_renumber_pkg.testIncrementInfoSlinNum(l_infoSlinNum);

Line 1068: -- l_nextNum := pon_clo_renumber_pkg.testIncrementInfoSlinNum(l_infoSlinNum);

1064: newslin := pon_clo_renumber_pkg.INCREMENT_PRICED_SLIN_NUMBER(newslin);
1065: END LOOP;
1066:
1067: RETURN newslin;
1068: -- l_nextNum := pon_clo_renumber_pkg.testIncrementInfoSlinNum(l_infoSlinNum);
1069: -- Dbms_Output.put_line(l_nextNum);
1070:
1071: EXCEPTION
1072: WHEN OTHERS THEN

Line 1323: module => 'pon.plsql.pon_clo_renumber_pkg',

1319: LINE_NUM_DISPLAY = p_clinnumber;
1320:
1321: IF (FND_LOG.level_statement >= FND_LOG.g_current_runtime_level) THEN
1322: FND_LOG.string(log_level => FND_LOG.level_statement,
1323: module => 'pon.plsql.pon_clo_renumber_pkg',
1324: message => substr('l_group_line_id : '||l_group_line_id, 0, 4000));
1325: END IF;
1326:
1327:

Line 1343: module => 'pon.plsql.pon_clo_renumber_pkg',

1339: LOOP
1340: FETCH all_slins INTO slnLineId, slnInfoFlg;
1341: IF (FND_LOG.level_statement >= FND_LOG.g_current_runtime_level) THEN
1342: FND_LOG.string(log_level => FND_LOG.level_statement,
1343: module => 'pon.plsql.pon_clo_renumber_pkg',
1344: message => substr('slnLineId : '||slnLineId, 0, 4000));
1345: FND_LOG.string(log_level => FND_LOG.level_statement,
1346: module => 'pon.plsql.pon_clo_renumber_pkg',
1347: message => substr('slnInfoFlg : '||slnInfoFlg, 0, 4000));

Line 1346: module => 'pon.plsql.pon_clo_renumber_pkg',

1342: FND_LOG.string(log_level => FND_LOG.level_statement,
1343: module => 'pon.plsql.pon_clo_renumber_pkg',
1344: message => substr('slnLineId : '||slnLineId, 0, 4000));
1345: FND_LOG.string(log_level => FND_LOG.level_statement,
1346: module => 'pon.plsql.pon_clo_renumber_pkg',
1347: message => substr('slnInfoFlg : '||slnInfoFlg, 0, 4000));
1348: END IF;
1349:
1350: IF all_slins%NOTFOUND THEN

Line 1368: module => 'pon.plsql.pon_clo_renumber_pkg',

1364: END;
1365: lastPricedSlin := INCREMENT_PRICED_SLIN_NUMBER(lastPricedSlin);
1366: IF (FND_LOG.level_statement >= FND_LOG.g_current_runtime_level) THEN
1367: FND_LOG.string(log_level => FND_LOG.level_statement,
1368: module => 'pon.plsql.pon_clo_renumber_pkg',
1369: message => substr('lastPricedSlin : '||lastPricedSlin, 0, 4000));
1370: END IF;
1371: ELSE
1372: l_updt_query := ' UPDATE PO_LINES_INTERFACE

Line 1384: module => 'pon.plsql.pon_clo_renumber_pkg',

1380: END;
1381: lastInfoSlin := INCREMENT_INFO_SLIN_NUMBER(lastInfoSlin);
1382: IF (FND_LOG.level_statement >= FND_LOG.g_current_runtime_level) THEN
1383: FND_LOG.string(log_level => FND_LOG.level_statement,
1384: module => 'pon.plsql.pon_clo_renumber_pkg',
1385: message => substr('lastInfoSlin : '||lastInfoSlin, 0, 4000));
1386: END IF;
1387: END IF;
1388: END LOOP;

Line 1434: next_clin := pon_clo_renumber_pkg.next_clin_num(tbl);

1430: /*FOR i IN 1..tbl.Count LOOP
1431: debug_clin_number(tbl(i));
1432: END LOOP; */
1433:
1434: next_clin := pon_clo_renumber_pkg.next_clin_num(tbl);
1435: RETURN next_clin;
1436:
1437: END NEXT_CLIN_NUM_WRAPPER3;
1438:

Line 1440: END PON_CLO_RENUMBER_PKG;

1436:
1437: END NEXT_CLIN_NUM_WRAPPER3;
1438:
1439:
1440: END PON_CLO_RENUMBER_PKG;